ABAP Select data from SAP table IEALLOCINSTTOPOD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IEALLOCINSTTOPOD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IEALLOCINSTTOPOD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IEALLOCINSTTOPOD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IEALLOCINSTTOPOD TYPE STANDARD TABLE OF IEALLOCINSTTOPOD,
      WA_IEALLOCINSTTOPOD TYPE IEALLOCINSTTOPOD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IEALLOCINSTTOPOD> TYPE IEALLOCINSTTOPOD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IEALLOCINSTTOPOD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IEALLOCINSTTOPOD
  INTO TABLE IT_IEALLOCINSTTOPOD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IEALLOCINSTTOPOD
*  INTO TABLE @DATA(IT_IEALLOCINSTTOPOD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IEALLOCINSTTOPOD INDEX 1 INTO DATA(WA_IEALLOCINSTTOPOD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IEALLOCINSTTOPOD ASSIGNING <IEALLOCINSTTOPOD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IEALLOCINSTTOPOD>-MANDT = 1.
<IEALLOCINSTTOPOD>-UTILSINTERNALPOINTOFDELIVERY = 1.
<IEALLOCINSTTOPOD>-UTILITIESINSTALLATION = 1.
<IEALLOCINSTTOPOD>-UTILSINSTTOPODALLOCENDDATE = 1.
<IEALLOCINSTTOPOD>-UTILSINSTTOPODALLOCENDTIME = 1.
ENDLOOP.

LOOP AT IT_IEALLOCINSTTOPOD INTO WA_IEALLOCINSTTOPOD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IEALLOCINSTTOPOD-UTILSINSTTOPODALLOCSTARTDATE, sy-vline,
WA_IEALLOCINSTTOPOD-UTILSINSTTOPODALLOCSTARTTIME, sy-vline,
WA_IEALLOCINSTTOPOD-UTILSPTOFDELIVERYISTECHNICAL, sy-vline,
WA_IEALLOCINSTTOPOD-UTILSPTOFDELIVERYISDEREGULATED, sy-vline,
WA_IEALLOCINSTTOPOD-AUTHORIZATIONGROUP, sy-vline,
ENDLOOP. *Add any further fields from structure WA_IEALLOCINSTTOPOD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IEALLOCINSTTOPOD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IEALLOCINSTTOPOD INTO WA_IEALLOCINSTTOPOD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field UTILITIESINSTALLATION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IEALLOCINSTTOPOD-UTILITIESINSTALLATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IEALLOCINSTTOPOD-UTILITIESINSTALLATION.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IEALLOCINSTTOPOD_STR,
MANDT TYPE STRING,
UTILSINTERNALPOINTOFDELIVERY TYPE STRING,
UTILITIESINSTALLATION TYPE STRING,
UTILSINSTTOPODALLOCENDDATE TYPE STRING,
UTILSINSTTOPODALLOCENDTIME TYPE STRING,
UTILSINSTTOPODALLOCSTARTDATE TYPE STRING,
UTILSINSTTOPODALLOCSTARTTIME TYPE STRING,
UTILSPTOFDELIVERYISTECHNICAL TYPE STRING,
UTILSPTOFDELIVERYISDEREGULATED TYPE STRING,
AUTHORIZATIONGROUP TYPE STRING,END OF T_EKKO_STR. DATA: WA_IEALLOCINSTTOPOD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IEALLOCINSTTOPOD_STR-MANDT sy-vline
WA_IEALLOCINSTTOPOD_STR-UTILSINTERNALPOINTOFDELIVERY sy-vline
WA_IEALLOCINSTTOPOD_STR-UTILITIESINSTALLATION sy-vline
WA_IEALLOCINSTTOPOD_STR-UTILSINSTTOPODALLOCENDDATE sy-vline
WA_IEALLOCINSTTOPOD_STR-UTILSINSTTOPODALLOCENDTIME sy-vline
WA_IEALLOCINSTTOPOD_STR-UTILSINSTTOPODALLOCSTARTDATE sy-vline
WA_IEALLOCINSTTOPOD_STR-UTILSINSTTOPODALLOCSTARTTIME sy-vline
WA_IEALLOCINSTTOPOD_STR-UTILSPTOFDELIVERYISTECHNICAL sy-vline
WA_IEALLOCINSTTOPOD_STR-UTILSPTOFDELIVERYISDEREGULATED sy-vline
WA_IEALLOCINSTTOPOD_STR-AUTHORIZATIONGROUP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.