ABAP Select data from SAP table IDFSMEASDOC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IDFSMEASDOC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IDFSMEASDOC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IDFSMEASDOC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IDFSMEASDOC TYPE STANDARD TABLE OF IDFSMEASDOC,
      WA_IDFSMEASDOC TYPE IDFSMEASDOC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IDFSMEASDOC> TYPE IDFSMEASDOC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IDFSMEASDOC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IDFSMEASDOC
  INTO TABLE IT_IDFSMEASDOC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IDFSMEASDOC
*  INTO TABLE @DATA(IT_IDFSMEASDOC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IDFSMEASDOC INDEX 1 INTO DATA(WA_IDFSMEASDOC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IDFSMEASDOC ASSIGNING <IDFSMEASDOC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IDFSMEASDOC>-MANDT = 1.
<IDFSMEASDOC>-EQUIPMENT = 1.
<IDFSMEASDOC>-DFSMAINTFUNCTIONALLOCATION = 1.
<IDFSMEASDOC>-MEASUREMENTDOCUMENT = 1.
<IDFSMEASDOC>-DFSMAINTFUNCNLDEPDNTOBJKEY = 1.
ENDLOOP.

LOOP AT IT_IDFSMEASDOC INTO WA_IDFSMEASDOC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IDFSMEASDOC-MEASURINGPOINT, sy-vline,
WA_IDFSMEASDOC-MEASURINGPOINTDESCRIPTION, sy-vline,
WA_IDFSMEASDOC-CHARACTERISTIC, sy-vline,
WA_IDFSMEASDOC-CHARCDESCRIPTION, sy-vline,
WA_IDFSMEASDOC-MSMTVALUATIONCODE, sy-vline,
WA_IDFSMEASDOC-MEASUREMENTDOCUMENTTEXT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IDFSMEASDOC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IDFSMEASDOC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IDFSMEASDOC INTO WA_IDFSMEASDOC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EQUIPMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IDFSMEASDOC-EQUIPMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IDFSMEASDOC-EQUIPMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEASUREMENTRANGEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IDFSMEASDOC-MEASUREMENTRANGEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IDFSMEASDOC-MEASUREMENTRANGEUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IDFSMEASDOC_STR,
MANDT TYPE STRING,
EQUIPMENT TYPE STRING,
DFSMAINTFUNCTIONALLOCATION TYPE STRING,
MEASUREMENTDOCUMENT TYPE STRING,
DFSMAINTFUNCNLDEPDNTOBJKEY TYPE STRING,
MEASURINGPOINT TYPE STRING,
MEASURINGPOINTDESCRIPTION TYPE STRING,
CHARACTERISTIC TYPE STRING,
CHARCDESCRIPTION TYPE STRING,
MSMTVALUATIONCODE TYPE STRING,
MEASUREMENTDOCUMENTTEXT TYPE STRING,
EQUIPMENTNAME TYPE STRING,
FUNCTIONALLOCATIONNAME TYPE STRING,
MSMTRDNGDATE TYPE STRING,
MSMTRDNGTIME TYPE STRING,
MEASUREMENTRANGEUNIT TYPE STRING,
MEASUREMENTREADINGINENTRYUOM TYPE STRING,
MEASURINGPOINTPOSITIONNUMBER TYPE STRING,
UNITOFMEASURETECHNICALNAME TYPE STRING,
SIUNITCNVRSNRATENUMERATOR TYPE STRING,
SIUNITCNVRSNRATEDENOMINATOR TYPE STRING,
MSMTCOUNTERREADINGDIFFERENCE TYPE STRING,
MEASUREMENTCOUNTERREADING TYPE STRING,
MEASUREMENTREADING TYPE STRING,
DFSMAINTEXPLOSIONTYPE TYPE STRING,
DFSMAINTEQUIPMENTUTILIZERID TYPE STRING,
TECHOBJECTWITHLEADINGZEROS TYPE STRING,END OF T_EKKO_STR. DATA: WA_IDFSMEASDOC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IDFSMEASDOC_STR-MANDT sy-vline
WA_IDFSMEASDOC_STR-EQUIPMENT sy-vline
WA_IDFSMEASDOC_STR-DFSMAINTFUNCTIONALLOCATION sy-vline
WA_IDFSMEASDOC_STR-MEASUREMENTDOCUMENT sy-vline
WA_IDFSMEASDOC_STR-DFSMAINTFUNCNLDEPDNTOBJKEY sy-vline
WA_IDFSMEASDOC_STR-MEASURINGPOINT sy-vline
WA_IDFSMEASDOC_STR-MEASURINGPOINTDESCRIPTION sy-vline
WA_IDFSMEASDOC_STR-CHARACTERISTIC sy-vline
WA_IDFSMEASDOC_STR-CHARCDESCRIPTION sy-vline
WA_IDFSMEASDOC_STR-MSMTVALUATIONCODE sy-vline
WA_IDFSMEASDOC_STR-MEASUREMENTDOCUMENTTEXT sy-vline
WA_IDFSMEASDOC_STR-EQUIPMENTNAME sy-vline
WA_IDFSMEASDOC_STR-FUNCTIONALLOCATIONNAME sy-vline
WA_IDFSMEASDOC_STR-MSMTRDNGDATE sy-vline
WA_IDFSMEASDOC_STR-MSMTRDNGTIME sy-vline
WA_IDFSMEASDOC_STR-MEASUREMENTRANGEUNIT sy-vline
WA_IDFSMEASDOC_STR-MEASUREMENTREADINGINENTRYUOM sy-vline
WA_IDFSMEASDOC_STR-MEASURINGPOINTPOSITIONNUMBER sy-vline
WA_IDFSMEASDOC_STR-UNITOFMEASURETECHNICALNAME sy-vline
WA_IDFSMEASDOC_STR-SIUNITCNVRSNRATENUMERATOR sy-vline
WA_IDFSMEASDOC_STR-SIUNITCNVRSNRATEDENOMINATOR sy-vline
WA_IDFSMEASDOC_STR-MSMTCOUNTERREADINGDIFFERENCE sy-vline
WA_IDFSMEASDOC_STR-MEASUREMENTCOUNTERREADING sy-vline
WA_IDFSMEASDOC_STR-MEASUREMENTREADING sy-vline
WA_IDFSMEASDOC_STR-DFSMAINTEXPLOSIONTYPE sy-vline
WA_IDFSMEASDOC_STR-DFSMAINTEQUIPMENTUTILIZERID sy-vline
WA_IDFSMEASDOC_STR-TECHOBJECTWITHLEADINGZEROS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.