ABAP Select data from SAP table IDFSASSGMTHIER into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IDFSASSGMTHIER table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IDFSASSGMTHIER. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IDFSASSGMTHIER table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IDFSASSGMTHIER TYPE STANDARD TABLE OF IDFSASSGMTHIER,
      WA_IDFSASSGMTHIER TYPE IDFSASSGMTHIER,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IDFSASSGMTHIER> TYPE IDFSASSGMTHIER.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IDFSASSGMTHIER.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IDFSASSGMTHIER
  INTO TABLE IT_IDFSASSGMTHIER.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IDFSASSGMTHIER
*  INTO TABLE @DATA(IT_IDFSASSGMTHIER2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IDFSASSGMTHIER INDEX 1 INTO DATA(WA_IDFSASSGMTHIER2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IDFSASSGMTHIER ASSIGNING <IDFSASSGMTHIER>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IDFSASSGMTHIER>-MANDT = 1.
<IDFSASSGMTHIER>-FLXBLMATLPLNGOBJVARIANTUUID = 1.
<IDFSASSGMTHIER>-FLXMTPLOBJVARIANTACCOGPRTUUID = 1.
<IDFSASSGMTHIER>-FLXBLMATLPLNGOBJECTUUID = 1.
<IDFSASSGMTHIER>-DFSASSGMTSOURCEOBJECTUUID = 1.
ENDLOOP.

LOOP AT IT_IDFSASSGMTHIER INTO WA_IDFSASSGMTHIER.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IDFSASSGMTHIER-FLXBLMATLPLNGOBJECTID, sy-vline,
WA_IDFSASSGMTHIER-FLXMTPLOBJVARACCOGPRTREFOBJID, sy-vline,
WA_IDFSASSGMTHIER-FLXMTPLOBJVARACCOGPARTITEM, sy-vline,
WA_IDFSASSGMTHIER-FLXMTPLOBJVARSTATUSCODE, sy-vline,
WA_IDFSASSGMTHIER-FLXMTPLOBJVARSTATUSDESCRIPTION, sy-vline,
WA_IDFSASSGMTHIER-FLXMTPLOBJVARACCOGPRTAUTHZDVAL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IDFSASSGMTHIER you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IDFSASSGMTHIER TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IDFSASSGMTHIER INTO WA_IDFSASSGMTHIER. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IDFSASSGMTHIER_STR,
MANDT TYPE STRING,
FLXBLMATLPLNGOBJVARIANTUUID TYPE STRING,
FLXMTPLOBJVARIANTACCOGPRTUUID TYPE STRING,
FLXBLMATLPLNGOBJECTUUID TYPE STRING,
DFSASSGMTSOURCEOBJECTUUID TYPE STRING,
FLXBLMATLPLNGOBJECTID TYPE STRING,
FLXMTPLOBJVARACCOGPRTREFOBJID TYPE STRING,
FLXMTPLOBJVARACCOGPARTITEM TYPE STRING,
FLXMTPLOBJVARSTATUSCODE TYPE STRING,
FLXMTPLOBJVARSTATUSDESCRIPTION TYPE STRING,
FLXMTPLOBJVARACCOGPRTAUTHZDVAL TYPE STRING,
FLXMTPLOBJVARACCOGPARTASSGMT TYPE STRING,
FLXMTPLOBJVARACCOGPRTREFVARID TYPE STRING,
FLXBLMATLPLNGOBJVARIANTDESC TYPE STRING,
FLXBLMATLPLNGOBJDESCRIPTION TYPE STRING,
FLXBLMATLPLNGOBJVARIANTID TYPE STRING,
DFSASSGMTSTATUSOBJECT TYPE STRING,END OF T_EKKO_STR. DATA: WA_IDFSASSGMTHIER_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IDFSASSGMTHIER_STR-MANDT sy-vline
WA_IDFSASSGMTHIER_STR-FLXBLMATLPLNGOBJVARIANTUUID sy-vline
WA_IDFSASSGMTHIER_STR-FLXMTPLOBJVARIANTACCOGPRTUUID sy-vline
WA_IDFSASSGMTHIER_STR-FLXBLMATLPLNGOBJECTUUID sy-vline
WA_IDFSASSGMTHIER_STR-DFSASSGMTSOURCEOBJECTUUID sy-vline
WA_IDFSASSGMTHIER_STR-FLXBLMATLPLNGOBJECTID sy-vline
WA_IDFSASSGMTHIER_STR-FLXMTPLOBJVARACCOGPRTREFOBJID sy-vline
WA_IDFSASSGMTHIER_STR-FLXMTPLOBJVARACCOGPARTITEM sy-vline
WA_IDFSASSGMTHIER_STR-FLXMTPLOBJVARSTATUSCODE sy-vline
WA_IDFSASSGMTHIER_STR-FLXMTPLOBJVARSTATUSDESCRIPTION sy-vline
WA_IDFSASSGMTHIER_STR-FLXMTPLOBJVARACCOGPRTAUTHZDVAL sy-vline
WA_IDFSASSGMTHIER_STR-FLXMTPLOBJVARACCOGPARTASSGMT sy-vline
WA_IDFSASSGMTHIER_STR-FLXMTPLOBJVARACCOGPRTREFVARID sy-vline
WA_IDFSASSGMTHIER_STR-FLXBLMATLPLNGOBJVARIANTDESC sy-vline
WA_IDFSASSGMTHIER_STR-FLXBLMATLPLNGOBJDESCRIPTION sy-vline
WA_IDFSASSGMTHIER_STR-FLXBLMATLPLNGOBJVARIANTID sy-vline
WA_IDFSASSGMTHIER_STR-DFSASSGMTSTATUSOBJECT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.