ABAP Select data from SAP table IDFSALLWNCPLANFE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IDFSALLWNCPLANFE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IDFSALLWNCPLANFE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IDFSALLWNCPLANFE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IDFSALLWNCPLANFE TYPE STANDARD TABLE OF IDFSALLWNCPLANFE,
      WA_IDFSALLWNCPLANFE TYPE IDFSALLWNCPLANFE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IDFSALLWNCPLANFE> TYPE IDFSALLWNCPLANFE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IDFSALLWNCPLANFE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IDFSALLWNCPLANFE
  INTO TABLE IT_IDFSALLWNCPLANFE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IDFSALLWNCPLANFE
*  INTO TABLE @DATA(IT_IDFSALLWNCPLANFE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IDFSALLWNCPLANFE INDEX 1 INTO DATA(WA_IDFSALLWNCPLANFE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IDFSALLWNCPLANFE ASSIGNING <IDFSALLWNCPLANFE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IDFSALLWNCPLANFE>-MANDT = 1.
<IDFSALLWNCPLANFE>-DFSALLWNCPLANUUID = 1.
<IDFSALLWNCPLANFE>-FORCEELEMENTORGUUID = 1.
<IDFSALLWNCPLANFE>-DFSALLWNCPLANASSIGNEDQUANTITY = 1.
<IDFSALLWNCPLANFE>-FORCEELEMENTORGTARGETUUID = 1.
ENDLOOP.

LOOP AT IT_IDFSALLWNCPLANFE INTO WA_IDFSALLWNCPLANFE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IDFSALLWNCPLANFE-DFSALLWNCPLANISFOLLOWUPPLAN, sy-vline,
WA_IDFSALLWNCPLANFE-DFSALLWNCPLANISFLLWUPPLANALLWD, sy-vline,
WA_IDFSALLWNCPLANFE-DFSALLWNCPLANCHANGEDATETIME, sy-vline,
WA_IDFSALLWNCPLANFE-FORCEELEMENTORGID, sy-vline,
WA_IDFSALLWNCPLANFE-DFSFRCELMNTISCHANGEABLE, sy-vline,
WA_IDFSALLWNCPLANFE-DFSALLWNCPLANQUANTITYUNIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IDFSALLWNCPLANFE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IDFSALLWNCPLANFE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IDFSALLWNCPLANFE INTO WA_IDFSALLWNCPLANFE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field DFSALLWNCPLANQUANTITYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IDFSALLWNCPLANFE-DFSALLWNCPLANQUANTITYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IDFSALLWNCPLANFE-DFSALLWNCPLANQUANTITYUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field PRODUCT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IDFSALLWNCPLANFE-PRODUCT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IDFSALLWNCPLANFE-PRODUCT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IDFSALLWNCPLANFE_STR,
MANDT TYPE STRING,
DFSALLWNCPLANUUID TYPE STRING,
FORCEELEMENTORGUUID TYPE STRING,
DFSALLWNCPLANASSIGNEDQUANTITY TYPE STRING,
FORCEELEMENTORGTARGETUUID TYPE STRING,
DFSALLWNCPLANISFOLLOWUPPLAN TYPE STRING,
DFSALLWNCPLANISFLLWUPPLANALLWD TYPE STRING,
DFSALLWNCPLANCHANGEDATETIME TYPE STRING,
FORCEELEMENTORGID TYPE STRING,
DFSFRCELMNTISCHANGEABLE TYPE STRING,
DFSALLWNCPLANQUANTITYUNIT TYPE STRING,
FRCELMNTORGUSAGETYPE TYPE STRING,
DFSALLWNCPLANVALDTYSTRTDATE TYPE STRING,
DFSALLWNCPLANVALDTYENDDATE TYPE STRING,
PRODUCT TYPE STRING,
FLXBLMATLPLNGOBJECTUUID TYPE STRING,
FLXBLMATLPLNGOBJVARIANTUUID TYPE STRING,
DFSALLWNCREQUUID TYPE STRING,END OF T_EKKO_STR. DATA: WA_IDFSALLWNCPLANFE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IDFSALLWNCPLANFE_STR-MANDT sy-vline
WA_IDFSALLWNCPLANFE_STR-DFSALLWNCPLANUUID sy-vline
WA_IDFSALLWNCPLANFE_STR-FORCEELEMENTORGUUID sy-vline
WA_IDFSALLWNCPLANFE_STR-DFSALLWNCPLANASSIGNEDQUANTITY sy-vline
WA_IDFSALLWNCPLANFE_STR-FORCEELEMENTORGTARGETUUID sy-vline
WA_IDFSALLWNCPLANFE_STR-DFSALLWNCPLANISFOLLOWUPPLAN sy-vline
WA_IDFSALLWNCPLANFE_STR-DFSALLWNCPLANISFLLWUPPLANALLWD sy-vline
WA_IDFSALLWNCPLANFE_STR-DFSALLWNCPLANCHANGEDATETIME sy-vline
WA_IDFSALLWNCPLANFE_STR-FORCEELEMENTORGID sy-vline
WA_IDFSALLWNCPLANFE_STR-DFSFRCELMNTISCHANGEABLE sy-vline
WA_IDFSALLWNCPLANFE_STR-DFSALLWNCPLANQUANTITYUNIT sy-vline
WA_IDFSALLWNCPLANFE_STR-FRCELMNTORGUSAGETYPE sy-vline
WA_IDFSALLWNCPLANFE_STR-DFSALLWNCPLANVALDTYSTRTDATE sy-vline
WA_IDFSALLWNCPLANFE_STR-DFSALLWNCPLANVALDTYENDDATE sy-vline
WA_IDFSALLWNCPLANFE_STR-PRODUCT sy-vline
WA_IDFSALLWNCPLANFE_STR-FLXBLMATLPLNGOBJECTUUID sy-vline
WA_IDFSALLWNCPLANFE_STR-FLXBLMATLPLNGOBJVARIANTUUID sy-vline
WA_IDFSALLWNCPLANFE_STR-DFSALLWNCREQUUID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.