ABAP Select data from SAP table IDCN_INVOUTPUT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IDCN_INVOUTPUT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IDCN_INVOUTPUT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IDCN_INVOUTPUT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IDCN_INVOUTPUT TYPE STANDARD TABLE OF IDCN_INVOUTPUT,
      WA_IDCN_INVOUTPUT TYPE IDCN_INVOUTPUT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IDCN_INVOUTPUT> TYPE IDCN_INVOUTPUT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IDCN_INVOUTPUT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IDCN_INVOUTPUT
  INTO TABLE IT_IDCN_INVOUTPUT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IDCN_INVOUTPUT
*  INTO TABLE @DATA(IT_IDCN_INVOUTPUT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IDCN_INVOUTPUT INDEX 1 INTO DATA(WA_IDCN_INVOUTPUT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IDCN_INVOUTPUT ASSIGNING <IDCN_INVOUTPUT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IDCN_INVOUTPUT>-BUKRS = 1.
<IDCN_INVOUTPUT>-RGTNO = 1.
<IDCN_INVOUTPUT>-INVNO = 1.
<IDCN_INVOUTPUT>-LOTNO = 1.
<IDCN_INVOUTPUT>-BOKNO = 1.
ENDLOOP.

LOOP AT IT_IDCN_INVOUTPUT INTO WA_IDCN_INVOUTPUT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IDCN_INVOUTPUT-ISSDT, sy-vline,
WA_IDCN_INVOUTPUT-VBELN, sy-vline,
WA_IDCN_INVOUTPUT-BELNR, sy-vline,
WA_IDCN_INVOUTPUT-GJAHR, sy-vline,
WA_IDCN_INVOUTPUT-KUNNR, sy-vline,
WA_IDCN_INVOUTPUT-NAME1, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IDCN_INVOUTPUT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IDCN_INVOUTPUT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IDCN_INVOUTPUT INTO WA_IDCN_INVOUTPUT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IDCN_INVOUTPUT-VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IDCN_INVOUTPUT-VBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IDCN_INVOUTPUT-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IDCN_INVOUTPUT-BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_IDCN_INVOUTPUT-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IDCN_INVOUTPUT-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IDCN_INVOUTPUT-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IDCN_INVOUTPUT-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IDCN_INVOUTPUT-WBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IDCN_INVOUTPUT-WBELN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IDCN_INVOUTPUT_STR,
BUKRS TYPE STRING,
RGTNO TYPE STRING,
INVNO TYPE STRING,
LOTNO TYPE STRING,
BOKNO TYPE STRING,
ISSDT TYPE STRING,
VBELN TYPE STRING,
BELNR TYPE STRING,
GJAHR TYPE STRING,
KUNNR TYPE STRING,
NAME1 TYPE STRING,
STCEG TYPE STRING,
ARKTX TYPE STRING,
HWBAS TYPE STRING,
TAXRT TYPE STRING,
HWSTE TYPE STRING,
VIDRS TYPE STRING,
VIDRT TYPE STRING,
EXCIF TYPE STRING,
XBLNR TYPE STRING,
WBELN TYPE STRING,END OF T_EKKO_STR. DATA: WA_IDCN_INVOUTPUT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IDCN_INVOUTPUT_STR-BUKRS sy-vline
WA_IDCN_INVOUTPUT_STR-RGTNO sy-vline
WA_IDCN_INVOUTPUT_STR-INVNO sy-vline
WA_IDCN_INVOUTPUT_STR-LOTNO sy-vline
WA_IDCN_INVOUTPUT_STR-BOKNO sy-vline
WA_IDCN_INVOUTPUT_STR-ISSDT sy-vline
WA_IDCN_INVOUTPUT_STR-VBELN sy-vline
WA_IDCN_INVOUTPUT_STR-BELNR sy-vline
WA_IDCN_INVOUTPUT_STR-GJAHR sy-vline
WA_IDCN_INVOUTPUT_STR-KUNNR sy-vline
WA_IDCN_INVOUTPUT_STR-NAME1 sy-vline
WA_IDCN_INVOUTPUT_STR-STCEG sy-vline
WA_IDCN_INVOUTPUT_STR-ARKTX sy-vline
WA_IDCN_INVOUTPUT_STR-HWBAS sy-vline
WA_IDCN_INVOUTPUT_STR-TAXRT sy-vline
WA_IDCN_INVOUTPUT_STR-HWSTE sy-vline
WA_IDCN_INVOUTPUT_STR-VIDRS sy-vline
WA_IDCN_INVOUTPUT_STR-VIDRT sy-vline
WA_IDCN_INVOUTPUT_STR-EXCIF sy-vline
WA_IDCN_INVOUTPUT_STR-XBLNR sy-vline
WA_IDCN_INVOUTPUT_STR-WBELN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.