ABAP Select data from SAP table ICRREFROUTINGBSC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ICRREFROUTINGBSC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ICRREFROUTINGBSC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ICRREFROUTINGBSC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ICRREFROUTINGBSC TYPE STANDARD TABLE OF ICRREFROUTINGBSC,
      WA_ICRREFROUTINGBSC TYPE ICRREFROUTINGBSC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ICRREFROUTINGBSC> TYPE ICRREFROUTINGBSC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ICRREFROUTINGBSC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ICRREFROUTINGBSC
  INTO TABLE IT_ICRREFROUTINGBSC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ICRREFROUTINGBSC
*  INTO TABLE @DATA(IT_ICRREFROUTINGBSC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ICRREFROUTINGBSC INDEX 1 INTO DATA(WA_ICRREFROUTINGBSC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ICRREFROUTINGBSC ASSIGNING <ICRREFROUTINGBSC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ICRREFROUTINGBSC>-MANDT = 1.
<ICRREFROUTINGBSC>-CHANGERECORDREFERENCEUUID = 1.
<ICRREFROUTINGBSC>-CHANGERECORD = 1.
<ICRREFROUTINGBSC>-CHGRECREFINTERNALKEY1 = 1.
<ICRREFROUTINGBSC>-CHGRECREFINTERNALKEY2 = 1.
ENDLOOP.

LOOP AT IT_ICRREFROUTINGBSC INTO WA_ICRREFROUTINGBSC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ICRREFROUTINGBSC-CHGRECREFINTERNALKEY3, sy-vline,
WA_ICRREFROUTINGBSC-CHGRECREFINTERNALKEY4, sy-vline,
WA_ICRREFROUTINGBSC-CHANGERECORDUUID, sy-vline,
WA_ICRREFROUTINGBSC-CHANGERECORDREFERENCETYPE, sy-vline,
WA_ICRREFROUTINGBSC-CHANGERECORDREFERENCESUBTYPE, sy-vline,
WA_ICRREFROUTINGBSC-CHANGERECORDREFOBJECTUUID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ICRREFROUTINGBSC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ICRREFROUTINGBSC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ICRREFROUTINGBSC INTO WA_ICRREFROUTINGBSC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CHANGERECORD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ICRREFROUTINGBSC-CHANGERECORD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICRREFROUTINGBSC-CHANGERECORD.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ICRREFROUTINGBSC_STR,
MANDT TYPE STRING,
CHANGERECORDREFERENCEUUID TYPE STRING,
CHANGERECORD TYPE STRING,
CHGRECREFINTERNALKEY1 TYPE STRING,
CHGRECREFINTERNALKEY2 TYPE STRING,
CHGRECREFINTERNALKEY3 TYPE STRING,
CHGRECREFINTERNALKEY4 TYPE STRING,
CHANGERECORDUUID TYPE STRING,
CHANGERECORDREFERENCETYPE TYPE STRING,
CHANGERECORDREFERENCESUBTYPE TYPE STRING,
CHANGERECORDREFOBJECTUUID TYPE STRING,
PARENTCHANGERECORDREFUUID TYPE STRING,
ISMAINREFERENCE TYPE STRING,
CHANGERECORDREFERENCE TYPE STRING,
CREATEDBYUSER TYPE STRING,
CREATIONDATETIME TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
LASTCHANGEDATETIME TYPE STRING,
CHANGERECORDVIRTUALREFIND TYPE STRING,
CHANGERECORDITEMRELEVANCE TYPE STRING,END OF T_EKKO_STR. DATA: WA_ICRREFROUTINGBSC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ICRREFROUTINGBSC_STR-MANDT sy-vline
WA_ICRREFROUTINGBSC_STR-CHANGERECORDREFERENCEUUID sy-vline
WA_ICRREFROUTINGBSC_STR-CHANGERECORD sy-vline
WA_ICRREFROUTINGBSC_STR-CHGRECREFINTERNALKEY1 sy-vline
WA_ICRREFROUTINGBSC_STR-CHGRECREFINTERNALKEY2 sy-vline
WA_ICRREFROUTINGBSC_STR-CHGRECREFINTERNALKEY3 sy-vline
WA_ICRREFROUTINGBSC_STR-CHGRECREFINTERNALKEY4 sy-vline
WA_ICRREFROUTINGBSC_STR-CHANGERECORDUUID sy-vline
WA_ICRREFROUTINGBSC_STR-CHANGERECORDREFERENCETYPE sy-vline
WA_ICRREFROUTINGBSC_STR-CHANGERECORDREFERENCESUBTYPE sy-vline
WA_ICRREFROUTINGBSC_STR-CHANGERECORDREFOBJECTUUID sy-vline
WA_ICRREFROUTINGBSC_STR-PARENTCHANGERECORDREFUUID sy-vline
WA_ICRREFROUTINGBSC_STR-ISMAINREFERENCE sy-vline
WA_ICRREFROUTINGBSC_STR-CHANGERECORDREFERENCE sy-vline
WA_ICRREFROUTINGBSC_STR-CREATEDBYUSER sy-vline
WA_ICRREFROUTINGBSC_STR-CREATIONDATETIME sy-vline
WA_ICRREFROUTINGBSC_STR-LASTCHANGEDBYUSER sy-vline
WA_ICRREFROUTINGBSC_STR-LASTCHANGEDATETIME sy-vline
WA_ICRREFROUTINGBSC_STR-CHANGERECORDVIRTUALREFIND sy-vline
WA_ICRREFROUTINGBSC_STR-CHANGERECORDITEMRELEVANCE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.