ABAP Select data from SAP table ICRITLFLSTRUC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ICRITLFLSTRUC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ICRITLFLSTRUC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ICRITLFLSTRUC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ICRITLFLSTRUC TYPE STANDARD TABLE OF ICRITLFLSTRUC,
      WA_ICRITLFLSTRUC TYPE ICRITLFLSTRUC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ICRITLFLSTRUC> TYPE ICRITLFLSTRUC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ICRITLFLSTRUC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ICRITLFLSTRUC
  INTO TABLE IT_ICRITLFLSTRUC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ICRITLFLSTRUC
*  INTO TABLE @DATA(IT_ICRITLFLSTRUC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ICRITLFLSTRUC INDEX 1 INTO DATA(WA_ICRITLFLSTRUC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ICRITLFLSTRUC ASSIGNING <ICRITLFLSTRUC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ICRITLFLSTRUC>-MANDT = 1.
<ICRITLFLSTRUC>-DFSMAINTFUNCTIONALLOCATION = 1.
<ICRITLFLSTRUC>-EQUIPMENT = 1.
<ICRITLFLSTRUC>-DFSMAINTEXPLOSIONTYPE = 1.
<ICRITLFLSTRUC>-DFSMAINTTAILNUMBER = 1.
ENDLOOP.

LOOP AT IT_ICRITLFLSTRUC INTO WA_ICRITLFLSTRUC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ICRITLFLSTRUC-FUNCTIONALLOCATIONNAME, sy-vline,
WA_ICRITLFLSTRUC-EQUIPMENTNAME, sy-vline,
WA_ICRITLFLSTRUC-SUPERORDINATEEQUIPMENT, sy-vline,
WA_ICRITLFLSTRUC-DFSMAINTSUPERORDINATEEQUIPNAME, sy-vline,
WA_ICRITLFLSTRUC-DFSMAINTMODELIDENTIFICATION, sy-vline,
WA_ICRITLFLSTRUC-DFSMAINTEQUIPTECHSTSSHRTNAME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ICRITLFLSTRUC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ICRITLFLSTRUC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ICRITLFLSTRUC INTO WA_ICRITLFLSTRUC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TPLNR, internal->external for field DFSMAINTFUNCTIONALLOCATION CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_ICRITLFLSTRUC-DFSMAINTFUNCTIONALLOCATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICRITLFLSTRUC-DFSMAINTFUNCTIONALLOCATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUIPMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ICRITLFLSTRUC-EQUIPMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICRITLFLSTRUC-EQUIPMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_ICRITLFLSTRUC-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICRITLFLSTRUC-MATERIAL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ICRITLFLSTRUC_STR,
MANDT TYPE STRING,
DFSMAINTFUNCTIONALLOCATION TYPE STRING,
EQUIPMENT TYPE STRING,
DFSMAINTEXPLOSIONTYPE TYPE STRING,
DFSMAINTTAILNUMBER TYPE STRING,
FUNCTIONALLOCATIONNAME TYPE STRING,
EQUIPMENTNAME TYPE STRING,
SUPERORDINATEEQUIPMENT TYPE STRING,
DFSMAINTSUPERORDINATEEQUIPNAME TYPE STRING,
DFSMAINTMODELIDENTIFICATION TYPE STRING,
DFSMAINTEQUIPTECHSTSSHRTNAME TYPE STRING,
DFSMAINTEQUIPOPLSTSSHRTNAME TYPE STRING,
DFSMAINTCRITICALITYTEXT TYPE STRING,
DFSMAINTTECHSTSAGGRGNEXECTEXT TYPE STRING,
DFSMAINTEQUIPMENTTYPE TYPE STRING,
DFSMAINTMASTEREQUIPTECHOBJNMBR TYPE STRING,
DFSMAINTTECHSTSAGGRGNISSTPPD TYPE STRING,
DFSMAINTEQUIPTECHSTATUSPROFILE TYPE STRING,
DFSMAINTREMARKTEXT TYPE STRING,
DFSMAINTACTUALCONFIGURATION TYPE STRING,
DFSMAINTFOREIGNEQUIPIDFGTEXT TYPE STRING,
DFSMAINTUSAGEPREFPRIORITY TYPE STRING,
DFSMAINTEQUIPOPLOBJNMBR TYPE STRING,
DFSMAINTSITEID TYPE STRING,
DFSMAINTSITEDESCRIPTION TYPE STRING,
DFSMAINTEQUIPMENTUTILIZERID TYPE STRING,
DFSMAINTEQUIPSTATUSICON TYPE STRING,
DFSMAINTEQUIPOPLSTATUSPROFILE TYPE STRING,
DFSMAINTEQUIPTECHSTSLONGNAME TYPE STRING,
DFSMAINTMODELDESCRIPTION TYPE STRING,
DFSMAINTMATERIALSERIALNUMBER TYPE STRING,
MATERIAL TYPE STRING,
MAINTOBJECTINTERNALID TYPE STRING,
DFSMAINTOPERATIONALROLE TYPE STRING,
DFSMAINTOPERATIONALROLEDESC TYPE STRING,
FLXMTPLOBJRIC TYPE STRING,
FLXMTPLOBJRICDESCRIPTION TYPE STRING,
FLXBLMATLPLNGOBJECTID TYPE STRING,
FLXBLMATLPLNGOBJDESCRIPTION TYPE STRING,
WORKCENTER TYPE STRING,
WORKCENTERTEXT TYPE STRING,
PLANT TYPE STRING,
DFSMAINTEQUIPMENTUTILIZERNAME TYPE STRING,
DFSMAINTEQUIPSTORAGELOCATION TYPE STRING,
FRCELMNTORGMRPSTOCKAREA TYPE STRING,
FRCELMNTORGPRVSNMRPAREA TYPE STRING,
DFSMAINTNUMBEROFNOTIFICATIONS TYPE STRING,
DFSMAINTNUMBEROFWORKORDERS TYPE STRING,
DFSMAINTTECHSTSICONURL TYPE STRING,
DFSMAINTOPLSTSICONURL TYPE STRING,
DFSMAINTEQUIPUSERSTSSHORTNAME TYPE STRING,
DFSMAINTEQUIPSYSTSTSSHORTNAME TYPE STRING,
TECHOBJECTWITHLEADINGZEROS TYPE STRING,END OF T_EKKO_STR. DATA: WA_ICRITLFLSTRUC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ICRITLFLSTRUC_STR-MANDT sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTFUNCTIONALLOCATION sy-vline
WA_ICRITLFLSTRUC_STR-EQUIPMENT sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTEXPLOSIONTYPE sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTTAILNUMBER sy-vline
WA_ICRITLFLSTRUC_STR-FUNCTIONALLOCATIONNAME sy-vline
WA_ICRITLFLSTRUC_STR-EQUIPMENTNAME sy-vline
WA_ICRITLFLSTRUC_STR-SUPERORDINATEEQUIPMENT sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTSUPERORDINATEEQUIPNAME sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTMODELIDENTIFICATION sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTEQUIPTECHSTSSHRTNAME sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTEQUIPOPLSTSSHRTNAME sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTCRITICALITYTEXT sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTTECHSTSAGGRGNEXECTEXT sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTEQUIPMENTTYPE sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTMASTEREQUIPTECHOBJNMBR sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTTECHSTSAGGRGNISSTPPD sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTEQUIPTECHSTATUSPROFILE sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTREMARKTEXT sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTACTUALCONFIGURATION sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTFOREIGNEQUIPIDFGTEXT sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTUSAGEPREFPRIORITY sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTEQUIPOPLOBJNMBR sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTSITEID sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTSITEDESCRIPTION sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTEQUIPMENTUTILIZERID sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTEQUIPSTATUSICON sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTEQUIPOPLSTATUSPROFILE sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTEQUIPTECHSTSLONGNAME sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTMODELDESCRIPTION sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTMATERIALSERIALNUMBER sy-vline
WA_ICRITLFLSTRUC_STR-MATERIAL sy-vline
WA_ICRITLFLSTRUC_STR-MAINTOBJECTINTERNALID sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTOPERATIONALROLE sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTOPERATIONALROLEDESC sy-vline
WA_ICRITLFLSTRUC_STR-FLXMTPLOBJRIC sy-vline
WA_ICRITLFLSTRUC_STR-FLXMTPLOBJRICDESCRIPTION sy-vline
WA_ICRITLFLSTRUC_STR-FLXBLMATLPLNGOBJECTID sy-vline
WA_ICRITLFLSTRUC_STR-FLXBLMATLPLNGOBJDESCRIPTION sy-vline
WA_ICRITLFLSTRUC_STR-WORKCENTER sy-vline
WA_ICRITLFLSTRUC_STR-WORKCENTERTEXT sy-vline
WA_ICRITLFLSTRUC_STR-PLANT sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTEQUIPMENTUTILIZERNAME sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTEQUIPSTORAGELOCATION sy-vline
WA_ICRITLFLSTRUC_STR-FRCELMNTORGMRPSTOCKAREA sy-vline
WA_ICRITLFLSTRUC_STR-FRCELMNTORGPRVSNMRPAREA sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTNUMBEROFNOTIFICATIONS sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTNUMBEROFWORKORDERS sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTTECHSTSICONURL sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTOPLSTSICONURL sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTEQUIPUSERSTSSHORTNAME sy-vline
WA_ICRITLFLSTRUC_STR-DFSMAINTEQUIPSYSTSTSSHORTNAME sy-vline
WA_ICRITLFLSTRUC_STR-TECHOBJECTWITHLEADINGZEROS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.