ABAP Select data from SAP table ICLX_NOTE_DATA_UI_S into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ICLX_NOTE_DATA_UI_S table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ICLX_NOTE_DATA_UI_S. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ICLX_NOTE_DATA_UI_S table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ICLX_NOTE_DATA_UI_S TYPE STANDARD TABLE OF ICLX_NOTE_DATA_UI_S,
      WA_ICLX_NOTE_DATA_UI_S TYPE ICLX_NOTE_DATA_UI_S,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ICLX_NOTE_DATA_UI_S> TYPE ICLX_NOTE_DATA_UI_S.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ICLX_NOTE_DATA_UI_S.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ICLX_NOTE_DATA_UI_S
  INTO TABLE IT_ICLX_NOTE_DATA_UI_S.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ICLX_NOTE_DATA_UI_S
*  INTO TABLE @DATA(IT_ICLX_NOTE_DATA_UI_S2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ICLX_NOTE_DATA_UI_S INDEX 1 INTO DATA(WA_ICLX_NOTE_DATA_UI_S2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ICLX_NOTE_DATA_UI_S ASSIGNING <ICLX_NOTE_DATA_UI_S>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ICLX_NOTE_DATA_UI_S>-ACTIVE = 1.
<ICLX_NOTE_DATA_UI_S>-CLAIM = 1.
<ICLX_NOTE_DATA_UI_S>-OBJYR = 1.
<ICLX_NOTE_DATA_UI_S>-OBJNO = 1.
<ICLX_NOTE_DATA_UI_S>-SUBCLAIM = 1.
ENDLOOP.

LOOP AT IT_ICLX_NOTE_DATA_UI_S INTO WA_ICLX_NOTE_DATA_UI_S.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ICLX_NOTE_DATA_UI_S-CLAIM_GUID, sy-vline,
WA_ICLX_NOTE_DATA_UI_S-SUBCLAIM_GUID, sy-vline,
WA_ICLX_NOTE_DATA_UI_S-NOTE_GUID, sy-vline,
WA_ICLX_NOTE_DATA_UI_S-CHANGETIME_DATE, sy-vline,
WA_ICLX_NOTE_DATA_UI_S-CHANGETIME_TIME, sy-vline,
WA_ICLX_NOTE_DATA_UI_S-CHANGEDBY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ICLX_NOTE_DATA_UI_S you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ICLX_NOTE_DATA_UI_S TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ICLX_NOTE_DATA_UI_S INTO WA_ICLX_NOTE_DATA_UI_S. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CLAIM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ICLX_NOTE_DATA_UI_S-CLAIM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICLX_NOTE_DATA_UI_S-CLAIM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ICLX_NOTE_DATA_UI_S_STR,
ACTIVE TYPE STRING,
CLAIM TYPE STRING,
OBJYR TYPE STRING,
OBJNO TYPE STRING,
SUBCLAIM TYPE STRING,
CLAIM_GUID TYPE STRING,
SUBCLAIM_GUID TYPE STRING,
NOTE_GUID TYPE STRING,
CHANGETIME_DATE TYPE STRING,
CHANGETIME_TIME TYPE STRING,
CHANGEDBY TYPE STRING,
NOTETYPE TYPE STRING,
COMCAT TYPE STRING,
COMTYPE TYPE STRING,
XTELFLAG TYPE STRING,
CHONAM TYPE STRING,
COMTIME_DATE TYPE STRING,
COMTIME_TIME TYPE STRING,
COMSTATUS TYPE STRING,
COMTIMEE_DATE TYPE STRING,
COMTIMEE_TIME TYPE STRING,
NOTECALLER TYPE STRING,
COMDATE TYPE STRING,
RESUBMISSION TYPE STRING,
AUTHGRP TYPE STRING,
PRIO TYPE STRING,
VALIDSTATUS TYPE STRING,
LEVEL_DESCR TYPE STRING,END OF T_EKKO_STR. DATA: WA_ICLX_NOTE_DATA_UI_S_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-ACTIVE sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-CLAIM sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-OBJYR sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-OBJNO sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-SUBCLAIM sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-CLAIM_GUID sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-SUBCLAIM_GUID sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-NOTE_GUID sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-CHANGETIME_DATE sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-CHANGETIME_TIME sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-CHANGEDBY sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-NOTETYPE sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-COMCAT sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-COMTYPE sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-XTELFLAG sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-CHONAM sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-COMTIME_DATE sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-COMTIME_TIME sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-COMSTATUS sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-COMTIMEE_DATE sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-COMTIMEE_TIME sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-NOTECALLER sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-COMDATE sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-RESUBMISSION sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-AUTHGRP sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-PRIO sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-VALIDSTATUS sy-vline
WA_ICLX_NOTE_DATA_UI_S_STR-LEVEL_DESCR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.