ABAP Select data from SAP table ICL_BW_PARTWC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ICL_BW_PARTWC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ICL_BW_PARTWC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ICL_BW_PARTWC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ICL_BW_PARTWC TYPE STANDARD TABLE OF ICL_BW_PARTWC,
      WA_ICL_BW_PARTWC TYPE ICL_BW_PARTWC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ICL_BW_PARTWC> TYPE ICL_BW_PARTWC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ICL_BW_PARTWC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ICL_BW_PARTWC
  INTO TABLE IT_ICL_BW_PARTWC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ICL_BW_PARTWC
*  INTO TABLE @DATA(IT_ICL_BW_PARTWC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ICL_BW_PARTWC INDEX 1 INTO DATA(WA_ICL_BW_PARTWC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ICL_BW_PARTWC ASSIGNING <ICL_BW_PARTWC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ICL_BW_PARTWC>-CLIENT = 1.
<ICL_BW_PARTWC>-ACTIVE = 1.
<ICL_BW_PARTWC>-CLAIM = 1.
<ICL_BW_PARTWC>-PARTNER = 1.
<ICL_BW_PARTWC>-ROLE = 1.
ENDLOOP.

LOOP AT IT_ICL_BW_PARTWC INTO WA_ICL_BW_PARTWC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ICL_BW_PARTWC-CHANGETIME, sy-vline,
WA_ICL_BW_PARTWC-CHANGEDBY, sy-vline,
WA_ICL_BW_PARTWC-DELETED, sy-vline,
WA_ICL_BW_PARTWC-EMP_PAYROLL, sy-vline,
WA_ICL_BW_PARTWC-EMP_INDUSTRYCODE, sy-vline,
WA_ICL_BW_PARTWC-EMP_UINUMBER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ICL_BW_PARTWC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ICL_BW_PARTWC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ICL_BW_PARTWC INTO WA_ICL_BW_PARTWC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CLAIM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ICL_BW_PARTWC-CLAIM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICL_BW_PARTWC-CLAIM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PARTNER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ICL_BW_PARTWC-PARTNER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICL_BW_PARTWC-PARTNER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTAM, internal->external for field CHANGETIME CALL FUNCTION 'CONVERSION_EXIT_TSTAM_OUTPUT' EXPORTING input = WA_ICL_BW_PARTWC-CHANGETIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICL_BW_PARTWC-CHANGETIME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ICL_BW_PARTWC_STR,
CLIENT TYPE STRING,
ACTIVE TYPE STRING,
CLAIM TYPE STRING,
PARTNER TYPE STRING,
ROLE TYPE STRING,
CHANGETIME TYPE STRING,
CHANGEDBY TYPE STRING,
DELETED TYPE STRING,
EMP_PAYROLL TYPE STRING,
EMP_INDUSTRYCODE TYPE STRING,
EMP_UINUMBER TYPE STRING,
EMP_NATOFBUS TYPE STRING,
EMP_LOCNUM TYPE STRING,
EMP_DATEREPTO TYPE STRING,
EMP_LOSSCOND_ACT TYPE STRING,
EMP_LOSS_TYPE TYPE STRING,
EMP_RECOVER_TYPE TYPE STRING,
EMP_COVERAG_TYPE TYPE STRING,
EMP_SETTLE_TYPE TYPE STRING,
EMPE_EMP_STATUS TYPE STRING,
EMPE_WAGEBASIS TYPE STRING,
EMPE_WORKDAYS TYPE STRING,
EMPE_NOOFDEP TYPE STRING,
EMPE_NOOFENTEXEM TYPE STRING,
EMPE_NOOFWHEXEM TYPE STRING,
EMPE_AWW TYPE STRING,
EMPE_OTHR_PAY TYPE STRING,
EMPE_DISCFB TYPE STRING,
EMPE_LDW TYPE STRING,
EMPE_RTW TYPE STRING,
EMPE_MMI_DATE TYPE STRING,
EMPE_WORKTIME TYPE STRING,
CURRENCY TYPE STRING,
EMPE_HIREDATE TYPE STRING,
EMPE_OCC_CODE TYPE STRING,
EMPE_MC_CODE TYPE STRING,
EMPE_OBJINJ TYPE STRING,
EMPE_INITTRMNTCO TYPE STRING,
EMPE_NOI TYPE STRING,
EMPE_COI TYPE STRING,
EMP_PREPAREDDATE TYPE STRING,
CLADMN_DATEREPTO TYPE STRING,
XINITIALPROVIDER TYPE STRING,
LAWY_STARTDATE TYPE STRING,
LAWY_DISCLOSURE TYPE STRING,
OSHA_CASE_NUM TYPE STRING,
BODY_PART_CODE TYPE STRING,
EMPE_DEATHDATE TYPE STRING,
ASSIGN_GUID TYPE STRING,
MCO_IDNUM TYPE STRING,
UPDMOD TYPE STRING,END OF T_EKKO_STR. DATA: WA_ICL_BW_PARTWC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ICL_BW_PARTWC_STR-CLIENT sy-vline
WA_ICL_BW_PARTWC_STR-ACTIVE sy-vline
WA_ICL_BW_PARTWC_STR-CLAIM sy-vline
WA_ICL_BW_PARTWC_STR-PARTNER sy-vline
WA_ICL_BW_PARTWC_STR-ROLE sy-vline
WA_ICL_BW_PARTWC_STR-CHANGETIME sy-vline
WA_ICL_BW_PARTWC_STR-CHANGEDBY sy-vline
WA_ICL_BW_PARTWC_STR-DELETED sy-vline
WA_ICL_BW_PARTWC_STR-EMP_PAYROLL sy-vline
WA_ICL_BW_PARTWC_STR-EMP_INDUSTRYCODE sy-vline
WA_ICL_BW_PARTWC_STR-EMP_UINUMBER sy-vline
WA_ICL_BW_PARTWC_STR-EMP_NATOFBUS sy-vline
WA_ICL_BW_PARTWC_STR-EMP_LOCNUM sy-vline
WA_ICL_BW_PARTWC_STR-EMP_DATEREPTO sy-vline
WA_ICL_BW_PARTWC_STR-EMP_LOSSCOND_ACT sy-vline
WA_ICL_BW_PARTWC_STR-EMP_LOSS_TYPE sy-vline
WA_ICL_BW_PARTWC_STR-EMP_RECOVER_TYPE sy-vline
WA_ICL_BW_PARTWC_STR-EMP_COVERAG_TYPE sy-vline
WA_ICL_BW_PARTWC_STR-EMP_SETTLE_TYPE sy-vline
WA_ICL_BW_PARTWC_STR-EMPE_EMP_STATUS sy-vline
WA_ICL_BW_PARTWC_STR-EMPE_WAGEBASIS sy-vline
WA_ICL_BW_PARTWC_STR-EMPE_WORKDAYS sy-vline
WA_ICL_BW_PARTWC_STR-EMPE_NOOFDEP sy-vline
WA_ICL_BW_PARTWC_STR-EMPE_NOOFENTEXEM sy-vline
WA_ICL_BW_PARTWC_STR-EMPE_NOOFWHEXEM sy-vline
WA_ICL_BW_PARTWC_STR-EMPE_AWW sy-vline
WA_ICL_BW_PARTWC_STR-EMPE_OTHR_PAY sy-vline
WA_ICL_BW_PARTWC_STR-EMPE_DISCFB sy-vline
WA_ICL_BW_PARTWC_STR-EMPE_LDW sy-vline
WA_ICL_BW_PARTWC_STR-EMPE_RTW sy-vline
WA_ICL_BW_PARTWC_STR-EMPE_MMI_DATE sy-vline
WA_ICL_BW_PARTWC_STR-EMPE_WORKTIME sy-vline
WA_ICL_BW_PARTWC_STR-CURRENCY sy-vline
WA_ICL_BW_PARTWC_STR-EMPE_HIREDATE sy-vline
WA_ICL_BW_PARTWC_STR-EMPE_OCC_CODE sy-vline
WA_ICL_BW_PARTWC_STR-EMPE_MC_CODE sy-vline
WA_ICL_BW_PARTWC_STR-EMPE_OBJINJ sy-vline
WA_ICL_BW_PARTWC_STR-EMPE_INITTRMNTCO sy-vline
WA_ICL_BW_PARTWC_STR-EMPE_NOI sy-vline
WA_ICL_BW_PARTWC_STR-EMPE_COI sy-vline
WA_ICL_BW_PARTWC_STR-EMP_PREPAREDDATE sy-vline
WA_ICL_BW_PARTWC_STR-CLADMN_DATEREPTO sy-vline
WA_ICL_BW_PARTWC_STR-XINITIALPROVIDER sy-vline
WA_ICL_BW_PARTWC_STR-LAWY_STARTDATE sy-vline
WA_ICL_BW_PARTWC_STR-LAWY_DISCLOSURE sy-vline
WA_ICL_BW_PARTWC_STR-OSHA_CASE_NUM sy-vline
WA_ICL_BW_PARTWC_STR-BODY_PART_CODE sy-vline
WA_ICL_BW_PARTWC_STR-EMPE_DEATHDATE sy-vline
WA_ICL_BW_PARTWC_STR-ASSIGN_GUID sy-vline
WA_ICL_BW_PARTWC_STR-MCO_IDNUM sy-vline
WA_ICL_BW_PARTWC_STR-UPDMOD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.