ABAP Select data from SAP table ICL_BS_ATTRIB_B into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ICL_BS_ATTRIB_B table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ICL_BS_ATTRIB_B. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ICL_BS_ATTRIB_B table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ICL_BS_ATTRIB_B TYPE STANDARD TABLE OF ICL_BS_ATTRIB_B,
      WA_ICL_BS_ATTRIB_B TYPE ICL_BS_ATTRIB_B,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ICL_BS_ATTRIB_B> TYPE ICL_BS_ATTRIB_B.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ICL_BS_ATTRIB_B.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ICL_BS_ATTRIB_B
  INTO TABLE IT_ICL_BS_ATTRIB_B.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ICL_BS_ATTRIB_B
*  INTO TABLE @DATA(IT_ICL_BS_ATTRIB_B2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ICL_BS_ATTRIB_B INDEX 1 INTO DATA(WA_ICL_BS_ATTRIB_B2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ICL_BS_ATTRIB_B ASSIGNING <ICL_BS_ATTRIB_B>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ICL_BS_ATTRIB_B>-CLIENT = 1.
<ICL_BS_ATTRIB_B>-ACTIVE = 1.
<ICL_BS_ATTRIB_B>-CCEVENT = 1.
<ICL_BS_ATTRIB_B>-CCTYPE = 1.
<ICL_BS_ATTRIB_B>-CCTYPEN = 1.
ENDLOOP.

LOOP AT IT_ICL_BS_ATTRIB_B INTO WA_ICL_BS_ATTRIB_B.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ICL_BS_ATTRIB_B-TYPE, sy-vline,
WA_ICL_BS_ATTRIB_B-SUBTYPE, sy-vline,
WA_ICL_BS_ATTRIB_B-SUBTYPENAME, sy-vline,
WA_ICL_BS_ATTRIB_B-CCSBRTYPE, sy-vline,
WA_ICL_BS_ATTRIB_B-CCSBRTYPEN, sy-vline,
WA_ICL_BS_ATTRIB_B-RANGEFROM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ICL_BS_ATTRIB_B you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ICL_BS_ATTRIB_B TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ICL_BS_ATTRIB_B INTO WA_ICL_BS_ATTRIB_B. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CCEVENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ICL_BS_ATTRIB_B-CCEVENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICL_BS_ATTRIB_B-CCEVENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_ICL_BS_ATTRIB_B-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICL_BS_ATTRIB_B-LANGU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LANGU2 CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_ICL_BS_ATTRIB_B-LANGU2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICL_BS_ATTRIB_B-LANGU2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTAM, internal->external for field CHANGETIME CALL FUNCTION 'CONVERSION_EXIT_TSTAM_OUTPUT' EXPORTING input = WA_ICL_BS_ATTRIB_B-CHANGETIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICL_BS_ATTRIB_B-CHANGETIME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ICL_BS_ATTRIB_B_STR,
CLIENT TYPE STRING,
ACTIVE TYPE STRING,
CCEVENT TYPE STRING,
CCTYPE TYPE STRING,
CCTYPEN TYPE STRING,
TYPE TYPE STRING,
SUBTYPE TYPE STRING,
SUBTYPENAME TYPE STRING,
CCSBRTYPE TYPE STRING,
CCSBRTYPEN TYPE STRING,
RANGEFROM TYPE STRING,
STATUS TYPE STRING,
STATUSN TYPE STRING,
LANGU TYPE STRING,
LANGU2 TYPE STRING,
SUBTYPE2 TYPE STRING,
CCSBRTYPE2 TYPE STRING,
CREATEDBY TYPE STRING,
CHANGEDBY TYPE STRING,
CHANGETIME TYPE STRING,END OF T_EKKO_STR. DATA: WA_ICL_BS_ATTRIB_B_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ICL_BS_ATTRIB_B_STR-CLIENT sy-vline
WA_ICL_BS_ATTRIB_B_STR-ACTIVE sy-vline
WA_ICL_BS_ATTRIB_B_STR-CCEVENT sy-vline
WA_ICL_BS_ATTRIB_B_STR-CCTYPE sy-vline
WA_ICL_BS_ATTRIB_B_STR-CCTYPEN sy-vline
WA_ICL_BS_ATTRIB_B_STR-TYPE sy-vline
WA_ICL_BS_ATTRIB_B_STR-SUBTYPE sy-vline
WA_ICL_BS_ATTRIB_B_STR-SUBTYPENAME sy-vline
WA_ICL_BS_ATTRIB_B_STR-CCSBRTYPE sy-vline
WA_ICL_BS_ATTRIB_B_STR-CCSBRTYPEN sy-vline
WA_ICL_BS_ATTRIB_B_STR-RANGEFROM sy-vline
WA_ICL_BS_ATTRIB_B_STR-STATUS sy-vline
WA_ICL_BS_ATTRIB_B_STR-STATUSN sy-vline
WA_ICL_BS_ATTRIB_B_STR-LANGU sy-vline
WA_ICL_BS_ATTRIB_B_STR-LANGU2 sy-vline
WA_ICL_BS_ATTRIB_B_STR-SUBTYPE2 sy-vline
WA_ICL_BS_ATTRIB_B_STR-CCSBRTYPE2 sy-vline
WA_ICL_BS_ATTRIB_B_STR-CREATEDBY sy-vline
WA_ICL_BS_ATTRIB_B_STR-CHANGEDBY sy-vline
WA_ICL_BS_ATTRIB_B_STR-CHANGETIME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.