ABAP Select data from SAP table ICL1STNFINSRDVEH into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ICL1STNFINSRDVEH table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ICL1STNFINSRDVEH. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ICL1STNFINSRDVEH table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ICL1STNFINSRDVEH TYPE STANDARD TABLE OF ICL1STNFINSRDVEH,
      WA_ICL1STNFINSRDVEH TYPE ICL1STNFINSRDVEH,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ICL1STNFINSRDVEH> TYPE ICL1STNFINSRDVEH.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ICL1STNFINSRDVEH.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ICL1STNFINSRDVEH
  INTO TABLE IT_ICL1STNFINSRDVEH.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ICL1STNFINSRDVEH
*  INTO TABLE @DATA(IT_ICL1STNFINSRDVEH2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ICL1STNFINSRDVEH INDEX 1 INTO DATA(WA_ICL1STNFINSRDVEH2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ICL1STNFINSRDVEH ASSIGNING <ICL1STNFINSRDVEH>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ICL1STNFINSRDVEH>-MANDT = 1.
<ICL1STNFINSRDVEH>-INSURANCECONTRACT = 1.
<ICL1STNFINSRDVEH>-INSURCLMVEHICLE = 1.
<ICL1STNFINSRDVEH>-INSURCLMVEHICLEMFR = 1.
<ICL1STNFINSRDVEH>-INSURCLMVEHICLEMODEL = 1.
ENDLOOP.

LOOP AT IT_ICL1STNFINSRDVEH INTO WA_ICL1STNFINSRDVEH.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ICL1STNFINSRDVEH-INSURCLMVIN, sy-vline,
WA_ICL1STNFINSRDVEH-INSURCLMVEHICLEPLATECOUNTRY, sy-vline,
WA_ICL1STNFINSRDVEH-INSURCLMVEHICLEPLATEREGION, sy-vline,
WA_ICL1STNFINSRDVEH-INSURCLMVEHICLEPLATENUMBER, sy-vline,
WA_ICL1STNFINSRDVEH-INSURCLMVEHICLEMODELYEAR, sy-vline,
WA_ICL1STNFINSRDVEH-INSURCLMVEHICLEENGINECAPACITY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ICL1STNFINSRDVEH you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ICL1STNFINSRDVEH TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ICL1STNFINSRDVEH INTO WA_ICL1STNFINSRDVEH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INSURANCECONTRACT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ICL1STNFINSRDVEH-INSURANCECONTRACT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICL1STNFINSRDVEH-INSURANCECONTRACT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field INSURCLMVEHICLEENGINECAPUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ICL1STNFINSRDVEH-INSURCLMVEHICLEENGINECAPUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICL1STNFINSRDVEH-INSURCLMVEHICLEENGINECAPUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ICL1STNFINSRDVEH_STR,
MANDT TYPE STRING,
INSURANCECONTRACT TYPE STRING,
INSURCLMVEHICLE TYPE STRING,
INSURCLMVEHICLEMFR TYPE STRING,
INSURCLMVEHICLEMODEL TYPE STRING,
INSURCLMVIN TYPE STRING,
INSURCLMVEHICLEPLATECOUNTRY TYPE STRING,
INSURCLMVEHICLEPLATEREGION TYPE STRING,
INSURCLMVEHICLEPLATENUMBER TYPE STRING,
INSURCLMVEHICLEMODELYEAR TYPE STRING,
INSURCLMVEHICLEENGINECAPACITY TYPE STRING,
INSURCLMVEHICLEENGINECAPUNIT TYPE STRING,
AUTHORIZATIONGROUP TYPE STRING,END OF T_EKKO_STR. DATA: WA_ICL1STNFINSRDVEH_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ICL1STNFINSRDVEH_STR-MANDT sy-vline
WA_ICL1STNFINSRDVEH_STR-INSURANCECONTRACT sy-vline
WA_ICL1STNFINSRDVEH_STR-INSURCLMVEHICLE sy-vline
WA_ICL1STNFINSRDVEH_STR-INSURCLMVEHICLEMFR sy-vline
WA_ICL1STNFINSRDVEH_STR-INSURCLMVEHICLEMODEL sy-vline
WA_ICL1STNFINSRDVEH_STR-INSURCLMVIN sy-vline
WA_ICL1STNFINSRDVEH_STR-INSURCLMVEHICLEPLATECOUNTRY sy-vline
WA_ICL1STNFINSRDVEH_STR-INSURCLMVEHICLEPLATEREGION sy-vline
WA_ICL1STNFINSRDVEH_STR-INSURCLMVEHICLEPLATENUMBER sy-vline
WA_ICL1STNFINSRDVEH_STR-INSURCLMVEHICLEMODELYEAR sy-vline
WA_ICL1STNFINSRDVEH_STR-INSURCLMVEHICLEENGINECAPACITY sy-vline
WA_ICL1STNFINSRDVEH_STR-INSURCLMVEHICLEENGINECAPUNIT sy-vline
WA_ICL1STNFINSRDVEH_STR-AUTHORIZATIONGROUP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.