ABAP Select data from SAP table ICFGGROUPWD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ICFGGROUPWD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ICFGGROUPWD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ICFGGROUPWD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ICFGGROUPWD TYPE STANDARD TABLE OF ICFGGROUPWD,
      WA_ICFGGROUPWD TYPE ICFGGROUPWD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ICFGGROUPWD> TYPE ICFGGROUPWD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ICFGGROUPWD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ICFGGROUPWD
  INTO TABLE IT_ICFGGROUPWD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ICFGGROUPWD
*  INTO TABLE @DATA(IT_ICFGGROUPWD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ICFGGROUPWD INDEX 1 INTO DATA(WA_ICFGGROUPWD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ICFGGROUPWD ASSIGNING <ICFGGROUPWD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ICFGGROUPWD>-MANDT = 1.
<ICFGGROUPWD>-CONFIGNCHARACTERISTICGROUP = 1.
<ICFGGROUPWD>-CHANGENUMBER = 1.
<ICFGGROUPWD>-CONFIGNCHARCGROUPFOREDIT = 1.
<ICFGGROUPWD>-CHANGENUMBERFOREDIT = 1.
ENDLOOP.

LOOP AT IT_ICFGGROUPWD INTO WA_ICFGGROUPWD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ICFGGROUPWD-TIMEINTERVALNUMBER, sy-vline,
WA_ICFGGROUPWD-CONFIGNCHARCGROUPISDEFAULT, sy-vline,
WA_ICFGGROUPWD-CREATEDBYUSER, sy-vline,
WA_ICFGGROUPWD-CREATIONDATE, sy-vline,
WA_ICFGGROUPWD-LASTCHANGEDBYUSER, sy-vline,
WA_ICFGGROUPWD-LASTCHANGEDATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ICFGGROUPWD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ICFGGROUPWD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ICFGGROUPWD INTO WA_ICFGGROUPWD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CHANGENUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ICFGGROUPWD-CHANGENUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICFGGROUPWD-CHANGENUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CHANGENUMBERFOREDIT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ICFGGROUPWD-CHANGENUMBERFOREDIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICFGGROUPWD-CHANGENUMBERFOREDIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ICFGGROUPWD_STR,
MANDT TYPE STRING,
CONFIGNCHARACTERISTICGROUP TYPE STRING,
CHANGENUMBER TYPE STRING,
CONFIGNCHARCGROUPFOREDIT TYPE STRING,
CHANGENUMBERFOREDIT TYPE STRING,
TIMEINTERVALNUMBER TYPE STRING,
CONFIGNCHARCGROUPISDEFAULT TYPE STRING,
CREATEDBYUSER TYPE STRING,
CREATIONDATE TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
LASTCHANGEDATE TYPE STRING,
VALIDITYSTARTDATE TYPE STRING,
VALIDITYENDDATE TYPE STRING,END OF T_EKKO_STR. DATA: WA_ICFGGROUPWD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ICFGGROUPWD_STR-MANDT sy-vline
WA_ICFGGROUPWD_STR-CONFIGNCHARACTERISTICGROUP sy-vline
WA_ICFGGROUPWD_STR-CHANGENUMBER sy-vline
WA_ICFGGROUPWD_STR-CONFIGNCHARCGROUPFOREDIT sy-vline
WA_ICFGGROUPWD_STR-CHANGENUMBERFOREDIT sy-vline
WA_ICFGGROUPWD_STR-TIMEINTERVALNUMBER sy-vline
WA_ICFGGROUPWD_STR-CONFIGNCHARCGROUPISDEFAULT sy-vline
WA_ICFGGROUPWD_STR-CREATEDBYUSER sy-vline
WA_ICFGGROUPWD_STR-CREATIONDATE sy-vline
WA_ICFGGROUPWD_STR-LASTCHANGEDBYUSER sy-vline
WA_ICFGGROUPWD_STR-LASTCHANGEDATE sy-vline
WA_ICFGGROUPWD_STR-VALIDITYSTARTDATE sy-vline
WA_ICFGGROUPWD_STR-VALIDITYENDDATE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.