ABAP Select data from SAP table ICFBUFFER into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ICFBUFFER table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ICFBUFFER. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ICFBUFFER table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ICFBUFFER TYPE STANDARD TABLE OF ICFBUFFER,
      WA_ICFBUFFER TYPE ICFBUFFER,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ICFBUFFER> TYPE ICFBUFFER.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ICFBUFFER.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ICFBUFFER
  INTO TABLE IT_ICFBUFFER.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ICFBUFFER
*  INTO TABLE @DATA(IT_ICFBUFFER2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ICFBUFFER INDEX 1 INTO DATA(WA_ICFBUFFER2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ICFBUFFER ASSIGNING <ICFBUFFER>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ICFBUFFER>-URL = 1.
<ICFBUFFER>-FIRSTALIAS = 1.
<ICFBUFFER>-SERVICENO = 1.
<ICFBUFFER>-URLSUFFIX = 1.
<ICFBUFFER>-PATHCOMP = 1.
ENDLOOP.

LOOP AT IT_ICFBUFFER INTO WA_ICFBUFFER.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ICFBUFFER-NO_CHILDS, sy-vline,
WA_ICFBUFFER-HANDLERLST, sy-vline,
WA_ICFBUFFER-ICF_NAME, sy-vline,
WA_ICFBUFFER-ICFPARGUID, sy-vline,
WA_ICFBUFFER-ICFNODGUID, sy-vline,
WA_ICFBUFFER-ICFALIFLAG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ICFBUFFER you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ICFBUFFER TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ICFBUFFER INTO WA_ICFBUFFER. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field ICF_LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_ICFBUFFER-ICF_LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICFBUFFER-ICF_LANGU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ICFBUFFER_STR,
URL TYPE STRING,
FIRSTALIAS TYPE STRING,
SERVICENO TYPE STRING,
URLSUFFIX TYPE STRING,
PATHCOMP TYPE STRING,
NO_CHILDS TYPE STRING,
HANDLERLST TYPE STRING,
ICF_NAME TYPE STRING,
ICFPARGUID TYPE STRING,
ICFNODGUID TYPE STRING,
ICFALIFLAG TYPE STRING,
ICFCHILDNO TYPE STRING,
ICFALIASNO TYPE STRING,
ICFNODFLAG TYPE STRING,
ICFALIGUID TYPE STRING,
ICF_EXPAND TYPE STRING,
ICF_MANDT TYPE STRING,
ICF_USER TYPE STRING,
ICF_PASSWD TYPE STRING,
ICF_LANGU TYPE STRING,
OBLUSRFLAG TYPE STRING,
PROTSEC TYPE STRING,
X509FLAG TYPE STRING,
SSLFLAG TYPE STRING,
ALIASLOGIN TYPE STRING,
ICF_AUTH TYPE STRING,
ICF_TCODE TYPE STRING,
ICF_NOACT TYPE STRING,
ICF_TRACE TYPE STRING,
ICF_DEBUG TYPE STRING,
ICF_EXPIR TYPE STRING,
ICF_OPTION TYPE STRING,
ICF_REDIR TYPE STRING,
ICF_TIME TYPE STRING,
ICF_CUSER TYPE STRING,
ICF_CDATE TYPE STRING,
ICF_MUSER TYPE STRING,
ICF_MDATE TYPE STRING,
ICF_HTTPS TYPE STRING,
ICF_AUTHRC TYPE STRING,
HDROTRCONC TYPE STRING,
BODOTRCONC TYPE STRING,
URL500 TYPE STRING,
KIND500 TYPE STRING,
HTTPCDE500 TYPE STRING,
HDROTR401 TYPE STRING,
BODOTR401 TYPE STRING,
URL401 TYPE STRING,
FORMFLG401 TYPE STRING,
KIND401 TYPE STRING,
HTTPCDE401 TYPE STRING,
ICFBITMAP TYPE STRING,
COMPR_FLAG TYPE STRING,
FALLTHRU TYPE STRING,
SYSLOG401 TYPE STRING,
LOG_FLAG TYPE STRING,
LOG_ORDER TYPE STRING,
HDROTRLPAG TYPE STRING,
BODOTRLPAG TYPE STRING,
URLLPAG TYPE STRING,
KINDLPAG TYPE STRING,
HTTPCDELPAG TYPE STRING,
ICFGUILNK TYPE STRING,
ICF_CCLNT TYPE STRING,
ICF_MCLNT TYPE STRING,
HDROTRNFPAG TYPE STRING,
BODOTRNFPAG TYPE STRING,
URLNFPAG TYPE STRING,
KINDNFPAG TYPE STRING,
HTTPCDENFPAG TYPE STRING,
APPLCUSTFLAG TYPE STRING,
ACCESSIBILITY TYPE STRING,
ICF_JAVA TYPE STRING,
LOGIN_PROCESS TYPE STRING,
KATEGORIE TYPE STRING,
READONLY TYPE STRING,
NOHEREDITY TYPE STRING,
SAML_FLAG TYPE STRING,
SYSLOGIN TYPE STRING,
ICF_ESI_FLAG TYPE STRING,
ICF_ESI_LOGON TYPE STRING,
ICF_REAUTH_OFF TYPE STRING,
NO_SESSION_MANAGEMENT TYPE STRING,
ORIG_NAME TYPE STRING,
LOGORDER TYPE STRING,
ICFALTNME TYPE STRING,
ICFALTNME_ORIG TYPE STRING,
PATHCOMP_LONG TYPE STRING,END OF T_EKKO_STR. DATA: WA_ICFBUFFER_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ICFBUFFER_STR-URL sy-vline
WA_ICFBUFFER_STR-FIRSTALIAS sy-vline
WA_ICFBUFFER_STR-SERVICENO sy-vline
WA_ICFBUFFER_STR-URLSUFFIX sy-vline
WA_ICFBUFFER_STR-PATHCOMP sy-vline
WA_ICFBUFFER_STR-NO_CHILDS sy-vline
WA_ICFBUFFER_STR-HANDLERLST sy-vline
WA_ICFBUFFER_STR-ICF_NAME sy-vline
WA_ICFBUFFER_STR-ICFPARGUID sy-vline
WA_ICFBUFFER_STR-ICFNODGUID sy-vline
WA_ICFBUFFER_STR-ICFALIFLAG sy-vline
WA_ICFBUFFER_STR-ICFCHILDNO sy-vline
WA_ICFBUFFER_STR-ICFALIASNO sy-vline
WA_ICFBUFFER_STR-ICFNODFLAG sy-vline
WA_ICFBUFFER_STR-ICFALIGUID sy-vline
WA_ICFBUFFER_STR-ICF_EXPAND sy-vline
WA_ICFBUFFER_STR-ICF_MANDT sy-vline
WA_ICFBUFFER_STR-ICF_USER sy-vline
WA_ICFBUFFER_STR-ICF_PASSWD sy-vline
WA_ICFBUFFER_STR-ICF_LANGU sy-vline
WA_ICFBUFFER_STR-OBLUSRFLAG sy-vline
WA_ICFBUFFER_STR-PROTSEC sy-vline
WA_ICFBUFFER_STR-X509FLAG sy-vline
WA_ICFBUFFER_STR-SSLFLAG sy-vline
WA_ICFBUFFER_STR-ALIASLOGIN sy-vline
WA_ICFBUFFER_STR-ICF_AUTH sy-vline
WA_ICFBUFFER_STR-ICF_TCODE sy-vline
WA_ICFBUFFER_STR-ICF_NOACT sy-vline
WA_ICFBUFFER_STR-ICF_TRACE sy-vline
WA_ICFBUFFER_STR-ICF_DEBUG sy-vline
WA_ICFBUFFER_STR-ICF_EXPIR sy-vline
WA_ICFBUFFER_STR-ICF_OPTION sy-vline
WA_ICFBUFFER_STR-ICF_REDIR sy-vline
WA_ICFBUFFER_STR-ICF_TIME sy-vline
WA_ICFBUFFER_STR-ICF_CUSER sy-vline
WA_ICFBUFFER_STR-ICF_CDATE sy-vline
WA_ICFBUFFER_STR-ICF_MUSER sy-vline
WA_ICFBUFFER_STR-ICF_MDATE sy-vline
WA_ICFBUFFER_STR-ICF_HTTPS sy-vline
WA_ICFBUFFER_STR-ICF_AUTHRC sy-vline
WA_ICFBUFFER_STR-HDROTRCONC sy-vline
WA_ICFBUFFER_STR-BODOTRCONC sy-vline
WA_ICFBUFFER_STR-URL500 sy-vline
WA_ICFBUFFER_STR-KIND500 sy-vline
WA_ICFBUFFER_STR-HTTPCDE500 sy-vline
WA_ICFBUFFER_STR-HDROTR401 sy-vline
WA_ICFBUFFER_STR-BODOTR401 sy-vline
WA_ICFBUFFER_STR-URL401 sy-vline
WA_ICFBUFFER_STR-FORMFLG401 sy-vline
WA_ICFBUFFER_STR-KIND401 sy-vline
WA_ICFBUFFER_STR-HTTPCDE401 sy-vline
WA_ICFBUFFER_STR-ICFBITMAP sy-vline
WA_ICFBUFFER_STR-COMPR_FLAG sy-vline
WA_ICFBUFFER_STR-FALLTHRU sy-vline
WA_ICFBUFFER_STR-SYSLOG401 sy-vline
WA_ICFBUFFER_STR-LOG_FLAG sy-vline
WA_ICFBUFFER_STR-LOG_ORDER sy-vline
WA_ICFBUFFER_STR-HDROTRLPAG sy-vline
WA_ICFBUFFER_STR-BODOTRLPAG sy-vline
WA_ICFBUFFER_STR-URLLPAG sy-vline
WA_ICFBUFFER_STR-KINDLPAG sy-vline
WA_ICFBUFFER_STR-HTTPCDELPAG sy-vline
WA_ICFBUFFER_STR-ICFGUILNK sy-vline
WA_ICFBUFFER_STR-ICF_CCLNT sy-vline
WA_ICFBUFFER_STR-ICF_MCLNT sy-vline
WA_ICFBUFFER_STR-HDROTRNFPAG sy-vline
WA_ICFBUFFER_STR-BODOTRNFPAG sy-vline
WA_ICFBUFFER_STR-URLNFPAG sy-vline
WA_ICFBUFFER_STR-KINDNFPAG sy-vline
WA_ICFBUFFER_STR-HTTPCDENFPAG sy-vline
WA_ICFBUFFER_STR-APPLCUSTFLAG sy-vline
WA_ICFBUFFER_STR-ACCESSIBILITY sy-vline
WA_ICFBUFFER_STR-ICF_JAVA sy-vline
WA_ICFBUFFER_STR-LOGIN_PROCESS sy-vline
WA_ICFBUFFER_STR-KATEGORIE sy-vline
WA_ICFBUFFER_STR-READONLY sy-vline
WA_ICFBUFFER_STR-NOHEREDITY sy-vline
WA_ICFBUFFER_STR-SAML_FLAG sy-vline
WA_ICFBUFFER_STR-SYSLOGIN sy-vline
WA_ICFBUFFER_STR-ICF_ESI_FLAG sy-vline
WA_ICFBUFFER_STR-ICF_ESI_LOGON sy-vline
WA_ICFBUFFER_STR-ICF_REAUTH_OFF sy-vline
WA_ICFBUFFER_STR-NO_SESSION_MANAGEMENT sy-vline
WA_ICFBUFFER_STR-ORIG_NAME sy-vline
WA_ICFBUFFER_STR-LOGORDER sy-vline
WA_ICFBUFFER_STR-ICFALTNME sy-vline
WA_ICFBUFFER_STR-ICFALTNME_ORIG sy-vline
WA_ICFBUFFER_STR-PATHCOMP_LONG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.