ABAP Select data from SAP table ICCTRPRICE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ICCTRPRICE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ICCTRPRICE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ICCTRPRICE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ICCTRPRICE TYPE STANDARD TABLE OF ICCTRPRICE,
      WA_ICCTRPRICE TYPE ICCTRPRICE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ICCTRPRICE> TYPE ICCTRPRICE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ICCTRPRICE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ICCTRPRICE
  INTO TABLE IT_ICCTRPRICE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ICCTRPRICE
*  INTO TABLE @DATA(IT_ICCTRPRICE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ICCTRPRICE INDEX 1 INTO DATA(WA_ICCTRPRICE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ICCTRPRICE ASSIGNING <ICCTRPRICE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ICCTRPRICE>-KOKRS = 1.
<ICCTRPRICE>-KOSTL = 1.
<ICCTRPRICE>-LSTAR = 1.
<ICCTRPRICE>-FISCPER = 1.
<ICCTRPRICE>-FISCVAR = 1.
ENDLOOP.

LOOP AT IT_ICCTRPRICE INTO WA_ICCTRPRICE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ICCTRPRICE-VKSTA, sy-vline,
WA_ICCTRPRICE-WRTTP, sy-vline,
WA_ICCTRPRICE-VTYPE, sy-vline,
WA_ICCTRPRICE-VERSN, sy-vline,
WA_ICCTRPRICE-ELEHK, sy-vline,
WA_ICCTRPRICE-ELEMT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ICCTRPRICE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ICCTRPRICE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ICCTRPRICE INTO WA_ICCTRPRICE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ICCTRPRICE-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICCTRPRICE-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PERI7, internal->external for field FISCPER CALL FUNCTION 'CONVERSION_EXIT_PERI7_OUTPUT' EXPORTING input = WA_ICCTRPRICE-FISCPER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICCTRPRICE-FISCPER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VKSTA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ICCTRPRICE-VKSTA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICCTRPRICE-VKSTA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ICCTRPRICE-VERSN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICCTRPRICE-VERSN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TARKZ CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ICCTRPRICE-TARKZ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICCTRPRICE-TARKZ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC112, internal->external for field STKG CALL FUNCTION 'CONVERSION_EXIT_AC112_OUTPUT' EXPORTING input = WA_ICCTRPRICE-STKG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICCTRPRICE-STKG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC112, internal->external for field STKF CALL FUNCTION 'CONVERSION_EXIT_AC112_OUTPUT' EXPORTING input = WA_ICCTRPRICE-STKF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICCTRPRICE-STKF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC112, internal->external for field STKV CALL FUNCTION 'CONVERSION_EXIT_AC112_OUTPUT' EXPORTING input = WA_ICCTRPRICE-STKV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICCTRPRICE-STKV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC112, internal->external for field STGRCOM CALL FUNCTION 'CONVERSION_EXIT_AC112_OUTPUT' EXPORTING input = WA_ICCTRPRICE-STGRCOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICCTRPRICE-STGRCOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC112, internal->external for field STFRCOM CALL FUNCTION 'CONVERSION_EXIT_AC112_OUTPUT' EXPORTING input = WA_ICCTRPRICE-STFRCOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICCTRPRICE-STFRCOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC112, internal->external for field STVRCOM CALL FUNCTION 'CONVERSION_EXIT_AC112_OUTPUT' EXPORTING input = WA_ICCTRPRICE-STVRCOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICCTRPRICE-STVRCOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ICCTRPRICE-LEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICCTRPRICE-LEINH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ICCTRPRICE_STR,
KOKRS TYPE STRING,
KOSTL TYPE STRING,
LSTAR TYPE STRING,
FISCPER TYPE STRING,
FISCVAR TYPE STRING,
VKSTA TYPE STRING,
WRTTP TYPE STRING,
VTYPE TYPE STRING,
VERSN TYPE STRING,
ELEHK TYPE STRING,
ELEMT TYPE STRING,
TARKZ TYPE STRING,
VALUTYP TYPE STRING,
MEASTYPE TYPE STRING,
STKG TYPE STRING,
STKF TYPE STRING,
STKV TYPE STRING,
STGRCOM TYPE STRING,
STFRCOM TYPE STRING,
STVRCOM TYPE STRING,
STKE TYPE STRING,
LEINH TYPE STRING,
WAERS TYPE STRING,
CURTYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_ICCTRPRICE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ICCTRPRICE_STR-KOKRS sy-vline
WA_ICCTRPRICE_STR-KOSTL sy-vline
WA_ICCTRPRICE_STR-LSTAR sy-vline
WA_ICCTRPRICE_STR-FISCPER sy-vline
WA_ICCTRPRICE_STR-FISCVAR sy-vline
WA_ICCTRPRICE_STR-VKSTA sy-vline
WA_ICCTRPRICE_STR-WRTTP sy-vline
WA_ICCTRPRICE_STR-VTYPE sy-vline
WA_ICCTRPRICE_STR-VERSN sy-vline
WA_ICCTRPRICE_STR-ELEHK sy-vline
WA_ICCTRPRICE_STR-ELEMT sy-vline
WA_ICCTRPRICE_STR-TARKZ sy-vline
WA_ICCTRPRICE_STR-VALUTYP sy-vline
WA_ICCTRPRICE_STR-MEASTYPE sy-vline
WA_ICCTRPRICE_STR-STKG sy-vline
WA_ICCTRPRICE_STR-STKF sy-vline
WA_ICCTRPRICE_STR-STKV sy-vline
WA_ICCTRPRICE_STR-STGRCOM sy-vline
WA_ICCTRPRICE_STR-STFRCOM sy-vline
WA_ICCTRPRICE_STR-STVRCOM sy-vline
WA_ICCTRPRICE_STR-STKE sy-vline
WA_ICCTRPRICE_STR-LEINH sy-vline
WA_ICCTRPRICE_STR-WAERS sy-vline
WA_ICCTRPRICE_STR-CURTYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.