ABAP Select data from SAP table ICASEATTRIBUTE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ICASEATTRIBUTE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ICASEATTRIBUTE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ICASEATTRIBUTE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ICASEATTRIBUTE TYPE STANDARD TABLE OF ICASEATTRIBUTE,
      WA_ICASEATTRIBUTE TYPE ICASEATTRIBUTE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ICASEATTRIBUTE> TYPE ICASEATTRIBUTE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ICASEATTRIBUTE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ICASEATTRIBUTE
  INTO TABLE IT_ICASEATTRIBUTE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ICASEATTRIBUTE
*  INTO TABLE @DATA(IT_ICASEATTRIBUTE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ICASEATTRIBUTE INDEX 1 INTO DATA(WA_ICASEATTRIBUTE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ICASEATTRIBUTE ASSIGNING <ICASEATTRIBUTE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ICASEATTRIBUTE>-MANDT = 1.
<ICASEATTRIBUTE>-CASEUNIQUEID = 1.
<ICASEATTRIBUTE>-CASETYPE = 1.
<ICASEATTRIBUTE>-CASEID = 1.
<ICASEATTRIBUTE>-CASEEXTERNALREFERENCE = 1.
ENDLOOP.

LOOP AT IT_ICASEATTRIBUTE INTO WA_ICASEATTRIBUTE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ICASEATTRIBUTE-CASECREATEDBY, sy-vline,
WA_ICASEATTRIBUTE-CASECREATEDON, sy-vline,
WA_ICASEATTRIBUTE-CASELASTCHANGEDBY, sy-vline,
WA_ICASEATTRIBUTE-CASELASTCHANGEDON, sy-vline,
WA_ICASEATTRIBUTE-CASECLOSEDBY, sy-vline,
WA_ICASEATTRIBUTE-CASECLOSEDTIME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ICASEATTRIBUTE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ICASEATTRIBUTE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ICASEATTRIBUTE INTO WA_ICASEATTRIBUTE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CASEID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ICASEATTRIBUTE-CASEID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICASEATTRIBUTE-CASEID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field CASECREATEDON CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_ICASEATTRIBUTE-CASECREATEDON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICASEATTRIBUTE-CASECREATEDON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field CASELASTCHANGEDON CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_ICASEATTRIBUTE-CASELASTCHANGEDON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICASEATTRIBUTE-CASELASTCHANGEDON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field CASECLOSEDTIME CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_ICASEATTRIBUTE-CASECLOSEDTIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICASEATTRIBUTE-CASECLOSEDTIME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ICASEATTRIBUTE_STR,
MANDT TYPE STRING,
CASEUNIQUEID TYPE STRING,
CASETYPE TYPE STRING,
CASEID TYPE STRING,
CASEEXTERNALREFERENCE TYPE STRING,
CASECREATEDBY TYPE STRING,
CASECREATEDON TYPE STRING,
CASELASTCHANGEDBY TYPE STRING,
CASELASTCHANGEDON TYPE STRING,
CASECLOSEDBY TYPE STRING,
CASECLOSEDTIME TYPE STRING,
CASEPLANNEDCLOSEDATE TYPE STRING,
CASEPROCESSOR TYPE STRING,
CASERESPONSIBLE TYPE STRING,
CASETITLE TYPE STRING,
CASEESCALATIONREASON TYPE STRING,
CASECATEGORY TYPE STRING,
CASEPRIORITY TYPE STRING,
CASEAUTHORIZATIONLEVEL TYPE STRING,
CASESTATUSPROFILE TYPE STRING,
CASESTATUS TYPE STRING,
CASESYSTEMSTATUS TYPE STRING,
CASESTATUSOBJECTNUMBER TYPE STRING,
CASESYSTEMSTATUSNAME TYPE STRING,
CASEUSERSTATUSNAME TYPE STRING,
CASEREASON TYPE STRING,END OF T_EKKO_STR. DATA: WA_ICASEATTRIBUTE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ICASEATTRIBUTE_STR-MANDT sy-vline
WA_ICASEATTRIBUTE_STR-CASEUNIQUEID sy-vline
WA_ICASEATTRIBUTE_STR-CASETYPE sy-vline
WA_ICASEATTRIBUTE_STR-CASEID sy-vline
WA_ICASEATTRIBUTE_STR-CASEEXTERNALREFERENCE sy-vline
WA_ICASEATTRIBUTE_STR-CASECREATEDBY sy-vline
WA_ICASEATTRIBUTE_STR-CASECREATEDON sy-vline
WA_ICASEATTRIBUTE_STR-CASELASTCHANGEDBY sy-vline
WA_ICASEATTRIBUTE_STR-CASELASTCHANGEDON sy-vline
WA_ICASEATTRIBUTE_STR-CASECLOSEDBY sy-vline
WA_ICASEATTRIBUTE_STR-CASECLOSEDTIME sy-vline
WA_ICASEATTRIBUTE_STR-CASEPLANNEDCLOSEDATE sy-vline
WA_ICASEATTRIBUTE_STR-CASEPROCESSOR sy-vline
WA_ICASEATTRIBUTE_STR-CASERESPONSIBLE sy-vline
WA_ICASEATTRIBUTE_STR-CASETITLE sy-vline
WA_ICASEATTRIBUTE_STR-CASEESCALATIONREASON sy-vline
WA_ICASEATTRIBUTE_STR-CASECATEGORY sy-vline
WA_ICASEATTRIBUTE_STR-CASEPRIORITY sy-vline
WA_ICASEATTRIBUTE_STR-CASEAUTHORIZATIONLEVEL sy-vline
WA_ICASEATTRIBUTE_STR-CASESTATUSPROFILE sy-vline
WA_ICASEATTRIBUTE_STR-CASESTATUS sy-vline
WA_ICASEATTRIBUTE_STR-CASESYSTEMSTATUS sy-vline
WA_ICASEATTRIBUTE_STR-CASESTATUSOBJECTNUMBER sy-vline
WA_ICASEATTRIBUTE_STR-CASESYSTEMSTATUSNAME sy-vline
WA_ICASEATTRIBUTE_STR-CASEUSERSTATUSNAME sy-vline
WA_ICASEATTRIBUTE_STR-CASEREASON sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.