ABAP Select data from SAP table IAUACEQUIDET into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IAUACEQUIDET table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IAUACEQUIDET. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IAUACEQUIDET table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IAUACEQUIDET TYPE STANDARD TABLE OF IAUACEQUIDET,
      WA_IAUACEQUIDET TYPE IAUACEQUIDET,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IAUACEQUIDET> TYPE IAUACEQUIDET.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IAUACEQUIDET.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IAUACEQUIDET
  INTO TABLE IT_IAUACEQUIDET.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IAUACEQUIDET
*  INTO TABLE @DATA(IT_IAUACEQUIDET2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IAUACEQUIDET INDEX 1 INTO DATA(WA_IAUACEQUIDET2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IAUACEQUIDET ASSIGNING <IAUACEQUIDET>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IAUACEQUIDET>-MANDT = 1.
<IAUACEQUIDET>-FORCEELEMENTORGSRCEID = 1.
<IAUACEQUIDET>-EQUIPMENT = 1.
<IAUACEQUIDET>-FRCELMNTORGSTOCKPLANT = 1.
<IAUACEQUIDET>-FRCELMNTORGSTOCKSTORAGELOC = 1.
ENDLOOP.

LOOP AT IT_IAUACEQUIDET INTO WA_IAUACEQUIDET.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IAUACEQUIDET-MATERIAL, sy-vline,
WA_IAUACEQUIDET-SERIALNUMBER, sy-vline,
WA_IAUACEQUIDET-UNIQUEITEMIDENTIFIER, sy-vline,
WA_IAUACEQUIDET-FUNCTIONALLOCATION, sy-vline,
WA_IAUACEQUIDET-PLANTNAME, sy-vline,
WA_IAUACEQUIDET-STORAGELOCATIONNAME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IAUACEQUIDET you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IAUACEQUIDET TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IAUACEQUIDET INTO WA_IAUACEQUIDET. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EQUIPMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IAUACEQUIDET-EQUIPMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IAUACEQUIDET-EQUIPMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IAUACEQUIDET-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IAUACEQUIDET-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field SERIALNUMBER CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_IAUACEQUIDET-SERIALNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IAUACEQUIDET-SERIALNUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field FUNCTIONALLOCATION CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_IAUACEQUIDET-FUNCTIONALLOCATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IAUACEQUIDET-FUNCTIONALLOCATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSN, internal->external for field WBSELEMENT CALL FUNCTION 'CONVERSION_EXIT_ABPSN_OUTPUT' EXPORTING input = WA_IAUACEQUIDET-WBSELEMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IAUACEQUIDET-WBSELEMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MATERIALBASEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IAUACEQUIDET-MATERIALBASEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IAUACEQUIDET-MATERIALBASEUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IAUACEQUIDET_STR,
MANDT TYPE STRING,
FORCEELEMENTORGSRCEID TYPE STRING,
EQUIPMENT TYPE STRING,
FRCELMNTORGSTOCKPLANT TYPE STRING,
FRCELMNTORGSTOCKSTORAGELOC TYPE STRING,
MATERIAL TYPE STRING,
SERIALNUMBER TYPE STRING,
UNIQUEITEMIDENTIFIER TYPE STRING,
FUNCTIONALLOCATION TYPE STRING,
PLANTNAME TYPE STRING,
STORAGELOCATIONNAME TYPE STRING,
MATERIALNAME TYPE STRING,
EQUIPMENTISINSTALLED TYPE STRING,
HASEQUIPMENTDATA TYPE STRING,
BATCH TYPE STRING,
WBSELEMENT TYPE STRING,
WBSDESCRIPTION TYPE STRING,
MATERIALGROUP TYPE STRING,
MATERIALBASEUNIT TYPE STRING,
FRCELMNTORGMRPSTOCKAREA TYPE STRING,
FRCELMNTORGNAME TYPE STRING,END OF T_EKKO_STR. DATA: WA_IAUACEQUIDET_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IAUACEQUIDET_STR-MANDT sy-vline
WA_IAUACEQUIDET_STR-FORCEELEMENTORGSRCEID sy-vline
WA_IAUACEQUIDET_STR-EQUIPMENT sy-vline
WA_IAUACEQUIDET_STR-FRCELMNTORGSTOCKPLANT sy-vline
WA_IAUACEQUIDET_STR-FRCELMNTORGSTOCKSTORAGELOC sy-vline
WA_IAUACEQUIDET_STR-MATERIAL sy-vline
WA_IAUACEQUIDET_STR-SERIALNUMBER sy-vline
WA_IAUACEQUIDET_STR-UNIQUEITEMIDENTIFIER sy-vline
WA_IAUACEQUIDET_STR-FUNCTIONALLOCATION sy-vline
WA_IAUACEQUIDET_STR-PLANTNAME sy-vline
WA_IAUACEQUIDET_STR-STORAGELOCATIONNAME sy-vline
WA_IAUACEQUIDET_STR-MATERIALNAME sy-vline
WA_IAUACEQUIDET_STR-EQUIPMENTISINSTALLED sy-vline
WA_IAUACEQUIDET_STR-HASEQUIPMENTDATA sy-vline
WA_IAUACEQUIDET_STR-BATCH sy-vline
WA_IAUACEQUIDET_STR-WBSELEMENT sy-vline
WA_IAUACEQUIDET_STR-WBSDESCRIPTION sy-vline
WA_IAUACEQUIDET_STR-MATERIALGROUP sy-vline
WA_IAUACEQUIDET_STR-MATERIALBASEUNIT sy-vline
WA_IAUACEQUIDET_STR-FRCELMNTORGMRPSTOCKAREA sy-vline
WA_IAUACEQUIDET_STR-FRCELMNTORGNAME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.