ABAP Select data from SAP table IACESOTP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IACESOTP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IACESOTP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IACESOTP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IACESOTP TYPE STANDARD TABLE OF IACESOTP,
      WA_IACESOTP TYPE IACESOTP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IACESOTP> TYPE IACESOTP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IACESOTP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IACESOTP
  INTO TABLE IT_IACESOTP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IACESOTP
*  INTO TABLE @DATA(IT_IACESOTP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IACESOTP INDEX 1 INTO DATA(WA_IACESOTP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IACESOTP ASSIGNING <IACESOTP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IACESOTP>-MANDT = 1.
<IACESOTP>-ACCRUALENGINEACCRUALOBJECTTYPE = 1.
<IACESOTP>-ACCRUALOBJECTLOGICALSYSTEM = 1.
<IACESOTP>-COMPANYCODE = 1.
<IACESOTP>-ACCRUALOBJECT = 1.
ENDLOOP.

LOOP AT IT_IACESOTP INTO WA_IACESOTP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IACESOTP-ACCRUALSUBOBJECT, sy-vline,
WA_IACESOTP-COMPANYCODENAME, sy-vline,
WA_IACESOTP-ACCRUALOBJECTINTERNALID, sy-vline,
WA_IACESOTP-ACCRUALSUBOBJECTINTERNALID, sy-vline,
WA_IACESOTP-ACCRSUBOBJPAUSEDATE, sy-vline,
WA_IACESOTP-ACCRSUBOBJSUSPENSIONDATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IACESOTP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IACESOTP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IACESOTP INTO WA_IACESOTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ACCRUALOBJECTLOGICALSYSTEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IACESOTP-ACCRUALOBJECTLOGICALSYSTEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IACESOTP-ACCRUALOBJECTLOGICALSYSTEM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IACESOTP_STR,
MANDT TYPE STRING,
ACCRUALENGINEACCRUALOBJECTTYPE TYPE STRING,
ACCRUALOBJECTLOGICALSYSTEM TYPE STRING,
COMPANYCODE TYPE STRING,
ACCRUALOBJECT TYPE STRING,
ACCRUALSUBOBJECT TYPE STRING,
COMPANYCODENAME TYPE STRING,
ACCRUALOBJECTINTERNALID TYPE STRING,
ACCRUALSUBOBJECTINTERNALID TYPE STRING,
ACCRSUBOBJPAUSEDATE TYPE STRING,
ACCRSUBOBJSUSPENSIONDATE TYPE STRING,
ACCRSUBOBJPREMATUREFINISHDATE TYPE STRING,
ACCRSUBOBJECTLIFECYCLESTATUS TYPE STRING,
ACCRSUBOBJLIFECYCLESTATUSNAME TYPE STRING,
ACCRSUBOBJHDRSTARTOFLIFEDATE TYPE STRING,
ACCRSUBOBJHDRENDOFLIFEDATE TYPE STRING,
ACCRUALSUBOBJECTCREATEDBYUSER TYPE STRING,
ACCRUALSUBOBJECTCREATIONDATE TYPE STRING,
ACCRUALSUBOBJECTCREATIONTIME TYPE STRING,
ACCRSUBOBJLASTCHANGEDBYUSER TYPE STRING,
ACCRUALSUBOBJECTLASTCHANGEDATE TYPE STRING,
ACCRUALSUBOBJECTLASTCHANGETIME TYPE STRING,END OF T_EKKO_STR. DATA: WA_IACESOTP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IACESOTP_STR-MANDT sy-vline
WA_IACESOTP_STR-ACCRUALENGINEACCRUALOBJECTTYPE sy-vline
WA_IACESOTP_STR-ACCRUALOBJECTLOGICALSYSTEM sy-vline
WA_IACESOTP_STR-COMPANYCODE sy-vline
WA_IACESOTP_STR-ACCRUALOBJECT sy-vline
WA_IACESOTP_STR-ACCRUALSUBOBJECT sy-vline
WA_IACESOTP_STR-COMPANYCODENAME sy-vline
WA_IACESOTP_STR-ACCRUALOBJECTINTERNALID sy-vline
WA_IACESOTP_STR-ACCRUALSUBOBJECTINTERNALID sy-vline
WA_IACESOTP_STR-ACCRSUBOBJPAUSEDATE sy-vline
WA_IACESOTP_STR-ACCRSUBOBJSUSPENSIONDATE sy-vline
WA_IACESOTP_STR-ACCRSUBOBJPREMATUREFINISHDATE sy-vline
WA_IACESOTP_STR-ACCRSUBOBJECTLIFECYCLESTATUS sy-vline
WA_IACESOTP_STR-ACCRSUBOBJLIFECYCLESTATUSNAME sy-vline
WA_IACESOTP_STR-ACCRSUBOBJHDRSTARTOFLIFEDATE sy-vline
WA_IACESOTP_STR-ACCRSUBOBJHDRENDOFLIFEDATE sy-vline
WA_IACESOTP_STR-ACCRUALSUBOBJECTCREATEDBYUSER sy-vline
WA_IACESOTP_STR-ACCRUALSUBOBJECTCREATIONDATE sy-vline
WA_IACESOTP_STR-ACCRUALSUBOBJECTCREATIONTIME sy-vline
WA_IACESOTP_STR-ACCRSUBOBJLASTCHANGEDBYUSER sy-vline
WA_IACESOTP_STR-ACCRUALSUBOBJECTLASTCHANGEDATE sy-vline
WA_IACESOTP_STR-ACCRUALSUBOBJECTLASTCHANGETIME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.