ABAP Select data from SAP table HUWM_LOAD_PROT_INT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HUWM_LOAD_PROT_INT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HUWM_LOAD_PROT_INT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HUWM_LOAD_PROT_INT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HUWM_LOAD_PROT_INT TYPE STANDARD TABLE OF HUWM_LOAD_PROT_INT,
      WA_HUWM_LOAD_PROT_INT TYPE HUWM_LOAD_PROT_INT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HUWM_LOAD_PROT_INT> TYPE HUWM_LOAD_PROT_INT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HUWM_LOAD_PROT_INT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HUWM_LOAD_PROT_INT
  INTO TABLE IT_HUWM_LOAD_PROT_INT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HUWM_LOAD_PROT_INT
*  INTO TABLE @DATA(IT_HUWM_LOAD_PROT_INT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HUWM_LOAD_PROT_INT INDEX 1 INTO DATA(WA_HUWM_LOAD_PROT_INT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HUWM_LOAD_PROT_INT ASSIGNING <HUWM_LOAD_PROT_INT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HUWM_LOAD_PROT_INT>-MANDT = 1.
<HUWM_LOAD_PROT_INT>-TOP_IDENT = 1.
<HUWM_LOAD_PROT_INT>-LINE = 1.
<HUWM_LOAD_PROT_INT>-EXIDV = 1.
<HUWM_LOAD_PROT_INT>-ITEM_TYPE = 1.
ENDLOOP.

LOOP AT IT_HUWM_LOAD_PROT_INT INTO WA_HUWM_LOAD_PROT_INT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HUWM_LOAD_PROT_INT-EXIDA, sy-vline,
WA_HUWM_LOAD_PROT_INT-VHILM, sy-vline,
WA_HUWM_LOAD_PROT_INT-EXIDV2, sy-vline,
WA_HUWM_LOAD_PROT_INT-BWLVS, sy-vline,
WA_HUWM_LOAD_PROT_INT-SQUIT, sy-vline,
WA_HUWM_LOAD_PROT_INT-LGNUM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HUWM_LOAD_PROT_INT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HUWM_LOAD_PROT_INT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HUWM_LOAD_PROT_INT INTO WA_HUWM_LOAD_PROT_INT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field TOP_IDENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HUWM_LOAD_PROT_INT-TOP_IDENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUWM_LOAD_PROT_INT-TOP_IDENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EXIDV CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HUWM_LOAD_PROT_INT-EXIDV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUWM_LOAD_PROT_INT-EXIDV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field VHILM CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_HUWM_LOAD_PROT_INT-VHILM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUWM_LOAD_PROT_INT-VHILM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EXIDV2 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HUWM_LOAD_PROT_INT-EXIDV2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUWM_LOAD_PROT_INT-EXIDV2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GEWEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_HUWM_LOAD_PROT_INT-GEWEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUWM_LOAD_PROT_INT-GEWEI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GEWEI_MAX CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_HUWM_LOAD_PROT_INT-GEWEI_MAX IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUWM_LOAD_PROT_INT-GEWEI_MAX.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOLEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_HUWM_LOAD_PROT_INT-VOLEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUWM_LOAD_PROT_INT-VOLEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOLEH_MAX CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_HUWM_LOAD_PROT_INT-VOLEH_MAX IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUWM_LOAD_PROT_INT-VOLEH_MAX.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEABM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_HUWM_LOAD_PROT_INT-MEABM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUWM_LOAD_PROT_INT-MEABM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit VHUPI, internal->external for field PACKVORSCH CALL FUNCTION 'CONVERSION_EXIT_VHUPI_OUTPUT' EXPORTING input = WA_HUWM_LOAD_PROT_INT-PACKVORSCH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUWM_LOAD_PROT_INT-PACKVORSCH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SUB_HU_EXIDV CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HUWM_LOAD_PROT_INT-SUB_HU_EXIDV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUWM_LOAD_PROT_INT-SUB_HU_EXIDV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ALTME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_HUWM_LOAD_PROT_INT-ALTME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUWM_LOAD_PROT_INT-ALTME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_HUWM_LOAD_PROT_INT-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUWM_LOAD_PROT_INT-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SONUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HUWM_LOAD_PROT_INT-SONUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUWM_LOAD_PROT_INT-SONUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field /CWM/ALTME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_HUWM_LOAD_PROT_INT-/CWM/ALTME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUWM_LOAD_PROT_INT-/CWM/ALTME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field SERNR CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_HUWM_LOAD_PROT_INT-SERNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUWM_LOAD_PROT_INT-SERNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EXIDV_NEW CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HUWM_LOAD_PROT_INT-EXIDV_NEW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUWM_LOAD_PROT_INT-EXIDV_NEW.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SUB_HU_NEW CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HUWM_LOAD_PROT_INT-SUB_HU_NEW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUWM_LOAD_PROT_INT-SUB_HU_NEW.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HUWM_LOAD_PROT_INT_STR,
MANDT TYPE STRING,
TOP_IDENT TYPE STRING,
LINE TYPE STRING,
EXIDV TYPE STRING,
ITEM_TYPE TYPE STRING,
EXIDA TYPE STRING,
VHILM TYPE STRING,
EXIDV2 TYPE STRING,
BWLVS TYPE STRING,
SQUIT TYPE STRING,
LGNUM TYPE STRING,
TARAG TYPE STRING,
GEWEI TYPE STRING,
MAGEW TYPE STRING,
NTGEW TYPE STRING,
BRGEW TYPE STRING,
GEWEI_MAX TYPE STRING,
GEWTO TYPE STRING,
TAVOL TYPE STRING,
VOLEH TYPE STRING,
MAVOL TYPE STRING,
NTVOL TYPE STRING,
BTVOL TYPE STRING,
VOLEH_MAX TYPE STRING,
GEWFX TYPE STRING,
LAENG TYPE STRING,
BREIT TYPE STRING,
HOEHE TYPE STRING,
MEABM TYPE STRING,
LETYP TYPE STRING,
NLTYP TYPE STRING,
NLBER TYPE STRING,
NLPLA TYPE STRING,
INHALT TYPE STRING,
ERLKZ TYPE STRING,
SORTL TYPE STRING,
VEGR1 TYPE STRING,
VEGR2 TYPE STRING,
VEGR3 TYPE STRING,
VEGR4 TYPE STRING,
VEGR5 TYPE STRING,
PACKVORSCH TYPE STRING,
PACKVORSCHR_ST TYPE STRING,
LABELTYP TYPE STRING,
ZUL_AUFL TYPE STRING,
SUB_HU_EXIDV TYPE STRING,
QUANTITY TYPE STRING,
ALTME TYPE STRING,
MATNR TYPE STRING,
CHARG TYPE STRING,
WERKS TYPE STRING,
LGORT TYPE STRING,
BESTQ TYPE STRING,
SOBKZ TYPE STRING,
SONUM TYPE STRING,
WDATU TYPE STRING,
VFDAT TYPE STRING,
ZEUGN TYPE STRING,
KZBEI TYPE STRING,
ANZSN TYPE STRING,
BWART TYPE STRING,
ITEM_ZEILE TYPE STRING,
HSDAT TYPE STRING,
/CWM/QUANTITY TYPE STRING,
/CWM/ALTME TYPE STRING,
ZEILE TYPE STRING,
SERNR TYPE STRING,
UII TYPE STRING,
EXIDV_NEW TYPE STRING,
SUB_HU_NEW TYPE STRING,
CREATED TYPE STRING,
POSTED TYPE STRING,
MSGID TYPE STRING,
MSGTY TYPE STRING,
MSGNO TYPE STRING,
MSGV1 TYPE STRING,
MSGV2 TYPE STRING,
MSGV3 TYPE STRING,
MSGV4 TYPE STRING,
UPDKZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_HUWM_LOAD_PROT_INT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HUWM_LOAD_PROT_INT_STR-MANDT sy-vline
WA_HUWM_LOAD_PROT_INT_STR-TOP_IDENT sy-vline
WA_HUWM_LOAD_PROT_INT_STR-LINE sy-vline
WA_HUWM_LOAD_PROT_INT_STR-EXIDV sy-vline
WA_HUWM_LOAD_PROT_INT_STR-ITEM_TYPE sy-vline
WA_HUWM_LOAD_PROT_INT_STR-EXIDA sy-vline
WA_HUWM_LOAD_PROT_INT_STR-VHILM sy-vline
WA_HUWM_LOAD_PROT_INT_STR-EXIDV2 sy-vline
WA_HUWM_LOAD_PROT_INT_STR-BWLVS sy-vline
WA_HUWM_LOAD_PROT_INT_STR-SQUIT sy-vline
WA_HUWM_LOAD_PROT_INT_STR-LGNUM sy-vline
WA_HUWM_LOAD_PROT_INT_STR-TARAG sy-vline
WA_HUWM_LOAD_PROT_INT_STR-GEWEI sy-vline
WA_HUWM_LOAD_PROT_INT_STR-MAGEW sy-vline
WA_HUWM_LOAD_PROT_INT_STR-NTGEW sy-vline
WA_HUWM_LOAD_PROT_INT_STR-BRGEW sy-vline
WA_HUWM_LOAD_PROT_INT_STR-GEWEI_MAX sy-vline
WA_HUWM_LOAD_PROT_INT_STR-GEWTO sy-vline
WA_HUWM_LOAD_PROT_INT_STR-TAVOL sy-vline
WA_HUWM_LOAD_PROT_INT_STR-VOLEH sy-vline
WA_HUWM_LOAD_PROT_INT_STR-MAVOL sy-vline
WA_HUWM_LOAD_PROT_INT_STR-NTVOL sy-vline
WA_HUWM_LOAD_PROT_INT_STR-BTVOL sy-vline
WA_HUWM_LOAD_PROT_INT_STR-VOLEH_MAX sy-vline
WA_HUWM_LOAD_PROT_INT_STR-GEWFX sy-vline
WA_HUWM_LOAD_PROT_INT_STR-LAENG sy-vline
WA_HUWM_LOAD_PROT_INT_STR-BREIT sy-vline
WA_HUWM_LOAD_PROT_INT_STR-HOEHE sy-vline
WA_HUWM_LOAD_PROT_INT_STR-MEABM sy-vline
WA_HUWM_LOAD_PROT_INT_STR-LETYP sy-vline
WA_HUWM_LOAD_PROT_INT_STR-NLTYP sy-vline
WA_HUWM_LOAD_PROT_INT_STR-NLBER sy-vline
WA_HUWM_LOAD_PROT_INT_STR-NLPLA sy-vline
WA_HUWM_LOAD_PROT_INT_STR-INHALT sy-vline
WA_HUWM_LOAD_PROT_INT_STR-ERLKZ sy-vline
WA_HUWM_LOAD_PROT_INT_STR-SORTL sy-vline
WA_HUWM_LOAD_PROT_INT_STR-VEGR1 sy-vline
WA_HUWM_LOAD_PROT_INT_STR-VEGR2 sy-vline
WA_HUWM_LOAD_PROT_INT_STR-VEGR3 sy-vline
WA_HUWM_LOAD_PROT_INT_STR-VEGR4 sy-vline
WA_HUWM_LOAD_PROT_INT_STR-VEGR5 sy-vline
WA_HUWM_LOAD_PROT_INT_STR-PACKVORSCH sy-vline
WA_HUWM_LOAD_PROT_INT_STR-PACKVORSCHR_ST sy-vline
WA_HUWM_LOAD_PROT_INT_STR-LABELTYP sy-vline
WA_HUWM_LOAD_PROT_INT_STR-ZUL_AUFL sy-vline
WA_HUWM_LOAD_PROT_INT_STR-SUB_HU_EXIDV sy-vline
WA_HUWM_LOAD_PROT_INT_STR-QUANTITY sy-vline
WA_HUWM_LOAD_PROT_INT_STR-ALTME sy-vline
WA_HUWM_LOAD_PROT_INT_STR-MATNR sy-vline
WA_HUWM_LOAD_PROT_INT_STR-CHARG sy-vline
WA_HUWM_LOAD_PROT_INT_STR-WERKS sy-vline
WA_HUWM_LOAD_PROT_INT_STR-LGORT sy-vline
WA_HUWM_LOAD_PROT_INT_STR-BESTQ sy-vline
WA_HUWM_LOAD_PROT_INT_STR-SOBKZ sy-vline
WA_HUWM_LOAD_PROT_INT_STR-SONUM sy-vline
WA_HUWM_LOAD_PROT_INT_STR-WDATU sy-vline
WA_HUWM_LOAD_PROT_INT_STR-VFDAT sy-vline
WA_HUWM_LOAD_PROT_INT_STR-ZEUGN sy-vline
WA_HUWM_LOAD_PROT_INT_STR-KZBEI sy-vline
WA_HUWM_LOAD_PROT_INT_STR-ANZSN sy-vline
WA_HUWM_LOAD_PROT_INT_STR-BWART sy-vline
WA_HUWM_LOAD_PROT_INT_STR-ITEM_ZEILE sy-vline
WA_HUWM_LOAD_PROT_INT_STR-HSDAT sy-vline
WA_HUWM_LOAD_PROT_INT_STR-/CWM/QUANTITY sy-vline
WA_HUWM_LOAD_PROT_INT_STR-/CWM/ALTME sy-vline
WA_HUWM_LOAD_PROT_INT_STR-ZEILE sy-vline
WA_HUWM_LOAD_PROT_INT_STR-SERNR sy-vline
WA_HUWM_LOAD_PROT_INT_STR-UII sy-vline
WA_HUWM_LOAD_PROT_INT_STR-EXIDV_NEW sy-vline
WA_HUWM_LOAD_PROT_INT_STR-SUB_HU_NEW sy-vline
WA_HUWM_LOAD_PROT_INT_STR-CREATED sy-vline
WA_HUWM_LOAD_PROT_INT_STR-POSTED sy-vline
WA_HUWM_LOAD_PROT_INT_STR-MSGID sy-vline
WA_HUWM_LOAD_PROT_INT_STR-MSGTY sy-vline
WA_HUWM_LOAD_PROT_INT_STR-MSGNO sy-vline
WA_HUWM_LOAD_PROT_INT_STR-MSGV1 sy-vline
WA_HUWM_LOAD_PROT_INT_STR-MSGV2 sy-vline
WA_HUWM_LOAD_PROT_INT_STR-MSGV3 sy-vline
WA_HUWM_LOAD_PROT_INT_STR-MSGV4 sy-vline
WA_HUWM_LOAD_PROT_INT_STR-UPDKZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.