ABAP Select data from SAP table HUS_JIT_CALL_HEADER into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HUS_JIT_CALL_HEADER table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HUS_JIT_CALL_HEADER. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HUS_JIT_CALL_HEADER table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HUS_JIT_CALL_HEADER TYPE STANDARD TABLE OF HUS_JIT_CALL_HEADER,
      WA_HUS_JIT_CALL_HEADER TYPE HUS_JIT_CALL_HEADER,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HUS_JIT_CALL_HEADER> TYPE HUS_JIT_CALL_HEADER.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HUS_JIT_CALL_HEADER.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HUS_JIT_CALL_HEADER
  INTO TABLE IT_HUS_JIT_CALL_HEADER.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HUS_JIT_CALL_HEADER
*  INTO TABLE @DATA(IT_HUS_JIT_CALL_HEADER2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HUS_JIT_CALL_HEADER INDEX 1 INTO DATA(WA_HUS_JIT_CALL_HEADER2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HUS_JIT_CALL_HEADER ASSIGNING <HUS_JIT_CALL_HEADER>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HUS_JIT_CALL_HEADER>-HANDLINGUNITEXTERNALID = 1.
<HUS_JIT_CALL_HEADER>-WAREHOUSE = 1.
<HUS_JIT_CALL_HEADER>-STOCKITEMUUID = 1.
<HUS_JIT_CALL_HEADER>-INT_CALL_NUM = 1.
<HUS_JIT_CALL_HEADER>-EXT_CALL_NUM = 1.
ENDLOOP.

LOOP AT IT_HUS_JIT_CALL_HEADER INTO WA_HUS_JIT_CALL_HEADER.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HUS_JIT_CALL_HEADER-CUSTOMERUUID, sy-vline,
WA_HUS_JIT_CALL_HEADER-KUNNR, sy-vline,
WA_HUS_JIT_CALL_HEADER-INT_SEQUENCE_NUM, sy-vline,
WA_HUS_JIT_CALL_HEADER-CALL_TYPE, sy-vline,
WA_HUS_JIT_CALL_HEADER-PLANNED_ORDER, sy-vline,
WA_HUS_JIT_CALL_HEADER-KUNAG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HUS_JIT_CALL_HEADER you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HUS_JIT_CALL_HEADER TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HUS_JIT_CALL_HEADER INTO WA_HUS_JIT_CALL_HEADER. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field HANDLINGUNITEXTERNALID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HUS_JIT_CALL_HEADER-HANDLINGUNITEXTERNALID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUS_JIT_CALL_HEADER-HANDLINGUNITEXTERNALID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INT_CALL_NUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HUS_JIT_CALL_HEADER-INT_CALL_NUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUS_JIT_CALL_HEADER-INT_CALL_NUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HUS_JIT_CALL_HEADER-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUS_JIT_CALL_HEADER-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLANNED_ORDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HUS_JIT_CALL_HEADER-PLANNED_ORDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUS_JIT_CALL_HEADER-PLANNED_ORDER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNAG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HUS_JIT_CALL_HEADER-KUNAG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUS_JIT_CALL_HEADER-KUNAG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HUS_JIT_CALL_HEADER-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUS_JIT_CALL_HEADER-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field VHCLE_MODEL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_HUS_JIT_CALL_HEADER-VHCLE_MODEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUS_JIT_CALL_HEADER-VHCLE_MODEL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BUSINESSTRANSACTIONDOCUMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HUS_JIT_CALL_HEADER-BUSINESSTRANSACTIONDOCUMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HUS_JIT_CALL_HEADER-BUSINESSTRANSACTIONDOCUMENT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HUS_JIT_CALL_HEADER_STR,
HANDLINGUNITEXTERNALID TYPE STRING,
WAREHOUSE TYPE STRING,
STOCKITEMUUID TYPE STRING,
INT_CALL_NUM TYPE STRING,
EXT_CALL_NUM TYPE STRING,
CUSTOMERUUID TYPE STRING,
KUNNR TYPE STRING,
INT_SEQUENCE_NUM TYPE STRING,
CALL_TYPE TYPE STRING,
PLANNED_ORDER TYPE STRING,
KUNAG TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
SPART TYPE STRING,
ABLAD TYPE STRING,
KNREF TYPE STRING,
ABRVW TYPE STRING,
LIFNR TYPE STRING,
MISSING_PARTS TYPE STRING,
LIFECYCLE_STAT TYPE STRING,
NJIT_SCENARIO TYPE STRING,
VHVIN TYPE STRING,
VHCLE_MODEL TYPE STRING,
LOG_SEVERITY TYPE STRING,
_DATAAGING TYPE STRING,
EXT_SEQUENCE_NUM TYPE STRING,
IMMEDIATE_REQUEST TYPE STRING,
SEQUENCE_DATE TYPE STRING,
CREA_DATE_TIME TYPE STRING,
CREA_UNAME TYPE STRING,
LCHG_DATE_TIME TYPE STRING,
LCHG_UNAME TYPE STRING,
DUMMY_NJIT_CALL_INCL_EEW_PS TYPE STRING,
DUMMY_NJIT_S2P_INCL_EEW_PS TYPE STRING,
CALL_CREATION_MODE TYPE STRING,
PRIORITY_TYPE TYPE STRING,
JITCOMPONENTISREORDERED TYPE STRING,
PRIORITY_ID TYPE STRING,
ARCHIVING_STATUS TYPE STRING,
BUSINESSTRANSACTIONDOCUMENT TYPE STRING,
DB_KEY TYPE STRING,END OF T_EKKO_STR. DATA: WA_HUS_JIT_CALL_HEADER_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HUS_JIT_CALL_HEADER_STR-HANDLINGUNITEXTERNALID sy-vline
WA_HUS_JIT_CALL_HEADER_STR-WAREHOUSE sy-vline
WA_HUS_JIT_CALL_HEADER_STR-STOCKITEMUUID sy-vline
WA_HUS_JIT_CALL_HEADER_STR-INT_CALL_NUM sy-vline
WA_HUS_JIT_CALL_HEADER_STR-EXT_CALL_NUM sy-vline
WA_HUS_JIT_CALL_HEADER_STR-CUSTOMERUUID sy-vline
WA_HUS_JIT_CALL_HEADER_STR-KUNNR sy-vline
WA_HUS_JIT_CALL_HEADER_STR-INT_SEQUENCE_NUM sy-vline
WA_HUS_JIT_CALL_HEADER_STR-CALL_TYPE sy-vline
WA_HUS_JIT_CALL_HEADER_STR-PLANNED_ORDER sy-vline
WA_HUS_JIT_CALL_HEADER_STR-KUNAG sy-vline
WA_HUS_JIT_CALL_HEADER_STR-VKORG sy-vline
WA_HUS_JIT_CALL_HEADER_STR-VTWEG sy-vline
WA_HUS_JIT_CALL_HEADER_STR-SPART sy-vline
WA_HUS_JIT_CALL_HEADER_STR-ABLAD sy-vline
WA_HUS_JIT_CALL_HEADER_STR-KNREF sy-vline
WA_HUS_JIT_CALL_HEADER_STR-ABRVW sy-vline
WA_HUS_JIT_CALL_HEADER_STR-LIFNR sy-vline
WA_HUS_JIT_CALL_HEADER_STR-MISSING_PARTS sy-vline
WA_HUS_JIT_CALL_HEADER_STR-LIFECYCLE_STAT sy-vline
WA_HUS_JIT_CALL_HEADER_STR-NJIT_SCENARIO sy-vline
WA_HUS_JIT_CALL_HEADER_STR-VHVIN sy-vline
WA_HUS_JIT_CALL_HEADER_STR-VHCLE_MODEL sy-vline
WA_HUS_JIT_CALL_HEADER_STR-LOG_SEVERITY sy-vline
WA_HUS_JIT_CALL_HEADER_STR-_DATAAGING sy-vline
WA_HUS_JIT_CALL_HEADER_STR-EXT_SEQUENCE_NUM sy-vline
WA_HUS_JIT_CALL_HEADER_STR-IMMEDIATE_REQUEST sy-vline
WA_HUS_JIT_CALL_HEADER_STR-SEQUENCE_DATE sy-vline
WA_HUS_JIT_CALL_HEADER_STR-CREA_DATE_TIME sy-vline
WA_HUS_JIT_CALL_HEADER_STR-CREA_UNAME sy-vline
WA_HUS_JIT_CALL_HEADER_STR-LCHG_DATE_TIME sy-vline
WA_HUS_JIT_CALL_HEADER_STR-LCHG_UNAME sy-vline
WA_HUS_JIT_CALL_HEADER_STR-DUMMY_NJIT_CALL_INCL_EEW_PS sy-vline
WA_HUS_JIT_CALL_HEADER_STR-DUMMY_NJIT_S2P_INCL_EEW_PS sy-vline
WA_HUS_JIT_CALL_HEADER_STR-CALL_CREATION_MODE sy-vline
WA_HUS_JIT_CALL_HEADER_STR-PRIORITY_TYPE sy-vline
WA_HUS_JIT_CALL_HEADER_STR-JITCOMPONENTISREORDERED sy-vline
WA_HUS_JIT_CALL_HEADER_STR-PRIORITY_ID sy-vline
WA_HUS_JIT_CALL_HEADER_STR-ARCHIVING_STATUS sy-vline
WA_HUS_JIT_CALL_HEADER_STR-BUSINESSTRANSACTIONDOCUMENT sy-vline
WA_HUS_JIT_CALL_HEADER_STR-DB_KEY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.