ABAP Select data from SAP table HSMT_DN into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HSMT_DN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HSMT_DN. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HSMT_DN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HSMT_DN TYPE STANDARD TABLE OF HSMT_DN,
      WA_HSMT_DN TYPE HSMT_DN,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HSMT_DN> TYPE HSMT_DN.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HSMT_DN.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HSMT_DN
  INTO TABLE IT_HSMT_DN.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HSMT_DN
*  INTO TABLE @DATA(IT_HSMT_DN2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HSMT_DN INDEX 1 INTO DATA(WA_HSMT_DN2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HSMT_DN ASSIGNING <HSMT_DN>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HSMT_DN>-MANDT = 1.
<HSMT_DN>-RECN = 1.
<HSMT_DN>-ACTN = 1.
<HSMT_DN>-VALFR = 1.
<HSMT_DN>-VALTO = 1.
ENDLOOP.

LOOP AT IT_HSMT_DN INTO WA_HSMT_DN.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HSMT_DN-AENNR, sy-vline,
WA_HSMT_DN-DELFLG, sy-vline,
WA_HSMT_DN-PARKFLG, sy-vline,
WA_HSMT_DN-CRDAT, sy-vline,
WA_HSMT_DN-CRNAM, sy-vline,
WA_HSMT_DN-UPDDAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HSMT_DN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HSMT_DN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HSMT_DN INTO WA_HSMT_DN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ACTN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HSMT_DN-ACTN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HSMT_DN-ACTN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HSMT_DN-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HSMT_DN-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OWNID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HSMT_DN-OWNID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HSMT_DN-OWNID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_HSMT_DN-UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HSMT_DN-UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HSMT_DN_STR,
MANDT TYPE STRING,
RECN TYPE STRING,
ACTN TYPE STRING,
VALFR TYPE STRING,
VALTO TYPE STRING,
AENNR TYPE STRING,
DELFLG TYPE STRING,
PARKFLG TYPE STRING,
CRDAT TYPE STRING,
CRNAM TYPE STRING,
UPDDAT TYPE STRING,
UPDNAM TYPE STRING,
SRSID TYPE STRING,
OWNID TYPE STRING,
RECNROOT TYPE STRING,
NUMTYPE TYPE STRING,
AVGVAL TYPE STRING,
AVGVALFLG TYPE STRING,
AVGDEC TYPE STRING,
LOWOP TYPE STRING,
LOWVAL TYPE STRING,
LOWVALFLG TYPE STRING,
LOWDEC TYPE STRING,
UPPOP TYPE STRING,
UPPVAL TYPE STRING,
UPPVALFLG TYPE STRING,
UPPDEC TYPE STRING,
UNIT TYPE STRING,END OF T_EKKO_STR. DATA: WA_HSMT_DN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HSMT_DN_STR-MANDT sy-vline
WA_HSMT_DN_STR-RECN sy-vline
WA_HSMT_DN_STR-ACTN sy-vline
WA_HSMT_DN_STR-VALFR sy-vline
WA_HSMT_DN_STR-VALTO sy-vline
WA_HSMT_DN_STR-AENNR sy-vline
WA_HSMT_DN_STR-DELFLG sy-vline
WA_HSMT_DN_STR-PARKFLG sy-vline
WA_HSMT_DN_STR-CRDAT sy-vline
WA_HSMT_DN_STR-CRNAM sy-vline
WA_HSMT_DN_STR-UPDDAT sy-vline
WA_HSMT_DN_STR-UPDNAM sy-vline
WA_HSMT_DN_STR-SRSID sy-vline
WA_HSMT_DN_STR-OWNID sy-vline
WA_HSMT_DN_STR-RECNROOT sy-vline
WA_HSMT_DN_STR-NUMTYPE sy-vline
WA_HSMT_DN_STR-AVGVAL sy-vline
WA_HSMT_DN_STR-AVGVALFLG sy-vline
WA_HSMT_DN_STR-AVGDEC sy-vline
WA_HSMT_DN_STR-LOWOP sy-vline
WA_HSMT_DN_STR-LOWVAL sy-vline
WA_HSMT_DN_STR-LOWVALFLG sy-vline
WA_HSMT_DN_STR-LOWDEC sy-vline
WA_HSMT_DN_STR-UPPOP sy-vline
WA_HSMT_DN_STR-UPPVAL sy-vline
WA_HSMT_DN_STR-UPPVALFLG sy-vline
WA_HSMT_DN_STR-UPPDEC sy-vline
WA_HSMT_DN_STR-UNIT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.