ABAP Select data from SAP table HSMS_MDIO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HSMS_MDIO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HSMS_MDIO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HSMS_MDIO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HSMS_MDIO TYPE STANDARD TABLE OF HSMS_MDIO,
      WA_HSMS_MDIO TYPE HSMS_MDIO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HSMS_MDIO> TYPE HSMS_MDIO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HSMS_MDIO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HSMS_MDIO
  INTO TABLE IT_HSMS_MDIO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HSMS_MDIO
*  INTO TABLE @DATA(IT_HSMS_MDIO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HSMS_MDIO INDEX 1 INTO DATA(WA_HSMS_MDIO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HSMS_MDIO ASSIGNING <HSMS_MDIO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HSMS_MDIO>-MARKFLG = 1.
<HSMS_MDIO>-SELEFLG = 1.
<HSMS_MDIO>-LINENO = 1.
<HSMS_MDIO>-LINEMOD = 1.
<HSMS_MDIO>-CHCOFLG = 1.
ENDLOOP.

LOOP AT IT_HSMS_MDIO INTO WA_HSMS_MDIO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HSMS_MDIO-LOCKMOD, sy-vline,
WA_HSMS_MDIO-INTRFLG, sy-vline,
WA_HSMS_MDIO-MANDT, sy-vline,
WA_HSMS_MDIO-RECN, sy-vline,
WA_HSMS_MDIO-ACTN, sy-vline,
WA_HSMS_MDIO-VALFR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HSMS_MDIO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HSMS_MDIO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HSMS_MDIO INTO WA_HSMS_MDIO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ACTN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HSMS_MDIO-ACTN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HSMS_MDIO-ACTN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HSMS_MDIO-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HSMS_MDIO-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OWNID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HSMS_MDIO-OWNID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HSMS_MDIO-OWNID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_HSMS_MDIO-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HSMS_MDIO-MATNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HSMS_MDIO_STR,
MARKFLG TYPE STRING,
SELEFLG TYPE STRING,
LINENO TYPE STRING,
LINEMOD TYPE STRING,
CHCOFLG TYPE STRING,
LOCKMOD TYPE STRING,
INTRFLG TYPE STRING,
MANDT TYPE STRING,
RECN TYPE STRING,
ACTN TYPE STRING,
VALFR TYPE STRING,
VALTO TYPE STRING,
AENNR TYPE STRING,
DELFLG TYPE STRING,
PARKFLG TYPE STRING,
CRDAT TYPE STRING,
CRNAM TYPE STRING,
UPDDAT TYPE STRING,
UPDNAM TYPE STRING,
SRSID TYPE STRING,
OWNID TYPE STRING,
RECNROOT TYPE STRING,
MATNR TYPE STRING,
COUNTRY TYPE STRING,
REGION TYPE STRING,
STOKEY1 TYPE STRING,
STOKEY2 TYPE STRING,
WPC TYPE STRING,
STWA TYPE STRING,
STMA TYPE STRING,
VBF TYPE STRING,
NAME TYPE STRING,
DESCR TYPE STRING,
STOCAT1 TYPE STRING,
STOCAT2 TYPE STRING,
STOCAT1TXT TYPE STRING,
STOCAT2TXT TYPE STRING,
STOKEY1TXT TYPE STRING,
STOKEY2TXT TYPE STRING,
STWATXT TYPE STRING,
STMATXT TYPE STRING,
VBFTXT TYPE STRING,
NAMETXT TYPE STRING,
DESCRTXT TYPE STRING,
MATERIALTXT TYPE STRING,
COUNTRYTXT TYPE STRING,
REGIONTXT TYPE STRING,
VALDAT TYPE STRING,END OF T_EKKO_STR. DATA: WA_HSMS_MDIO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HSMS_MDIO_STR-MARKFLG sy-vline
WA_HSMS_MDIO_STR-SELEFLG sy-vline
WA_HSMS_MDIO_STR-LINENO sy-vline
WA_HSMS_MDIO_STR-LINEMOD sy-vline
WA_HSMS_MDIO_STR-CHCOFLG sy-vline
WA_HSMS_MDIO_STR-LOCKMOD sy-vline
WA_HSMS_MDIO_STR-INTRFLG sy-vline
WA_HSMS_MDIO_STR-MANDT sy-vline
WA_HSMS_MDIO_STR-RECN sy-vline
WA_HSMS_MDIO_STR-ACTN sy-vline
WA_HSMS_MDIO_STR-VALFR sy-vline
WA_HSMS_MDIO_STR-VALTO sy-vline
WA_HSMS_MDIO_STR-AENNR sy-vline
WA_HSMS_MDIO_STR-DELFLG sy-vline
WA_HSMS_MDIO_STR-PARKFLG sy-vline
WA_HSMS_MDIO_STR-CRDAT sy-vline
WA_HSMS_MDIO_STR-CRNAM sy-vline
WA_HSMS_MDIO_STR-UPDDAT sy-vline
WA_HSMS_MDIO_STR-UPDNAM sy-vline
WA_HSMS_MDIO_STR-SRSID sy-vline
WA_HSMS_MDIO_STR-OWNID sy-vline
WA_HSMS_MDIO_STR-RECNROOT sy-vline
WA_HSMS_MDIO_STR-MATNR sy-vline
WA_HSMS_MDIO_STR-COUNTRY sy-vline
WA_HSMS_MDIO_STR-REGION sy-vline
WA_HSMS_MDIO_STR-STOKEY1 sy-vline
WA_HSMS_MDIO_STR-STOKEY2 sy-vline
WA_HSMS_MDIO_STR-WPC sy-vline
WA_HSMS_MDIO_STR-STWA sy-vline
WA_HSMS_MDIO_STR-STMA sy-vline
WA_HSMS_MDIO_STR-VBF sy-vline
WA_HSMS_MDIO_STR-NAME sy-vline
WA_HSMS_MDIO_STR-DESCR sy-vline
WA_HSMS_MDIO_STR-STOCAT1 sy-vline
WA_HSMS_MDIO_STR-STOCAT2 sy-vline
WA_HSMS_MDIO_STR-STOCAT1TXT sy-vline
WA_HSMS_MDIO_STR-STOCAT2TXT sy-vline
WA_HSMS_MDIO_STR-STOKEY1TXT sy-vline
WA_HSMS_MDIO_STR-STOKEY2TXT sy-vline
WA_HSMS_MDIO_STR-STWATXT sy-vline
WA_HSMS_MDIO_STR-STMATXT sy-vline
WA_HSMS_MDIO_STR-VBFTXT sy-vline
WA_HSMS_MDIO_STR-NAMETXT sy-vline
WA_HSMS_MDIO_STR-DESCRTXT sy-vline
WA_HSMS_MDIO_STR-MATERIALTXT sy-vline
WA_HSMS_MDIO_STR-COUNTRYTXT sy-vline
WA_HSMS_MDIO_STR-REGIONTXT sy-vline
WA_HSMS_MDIO_STR-VALDAT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.