ABAP Select data from SAP table HSMS_1119_STANDARD_FIELDS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HSMS_1119_STANDARD_FIELDS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HSMS_1119_STANDARD_FIELDS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HSMS_1119_STANDARD_FIELDS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HSMS_1119_STANDARD_FIELDS TYPE STANDARD TABLE OF HSMS_1119_STANDARD_FIELDS,
      WA_HSMS_1119_STANDARD_FIELDS TYPE HSMS_1119_STANDARD_FIELDS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HSMS_1119_STANDARD_FIELDS> TYPE HSMS_1119_STANDARD_FIELDS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HSMS_1119_STANDARD_FIELDS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HSMS_1119_STANDARD_FIELDS
  INTO TABLE IT_HSMS_1119_STANDARD_FIELDS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HSMS_1119_STANDARD_FIELDS
*  INTO TABLE @DATA(IT_HSMS_1119_STANDARD_FIELDS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HSMS_1119_STANDARD_FIELDS INDEX 1 INTO DATA(WA_HSMS_1119_STANDARD_FIELDS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HSMS_1119_STANDARD_FIELDS ASSIGNING <HSMS_1119_STANDARD_FIELDS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HSMS_1119_STANDARD_FIELDS>-FUNCTION = 1.
<HSMS_1119_STANDARD_FIELDS>-CLIENT = 1.
<HSMS_1119_STANDARD_FIELDS>-RECORD_NO = 1.
<HSMS_1119_STANDARD_FIELDS>-CHNGSTATUS = 1.
<HSMS_1119_STANDARD_FIELDS>-VALID_FROM = 1.
ENDLOOP.

LOOP AT IT_HSMS_1119_STANDARD_FIELDS INTO WA_HSMS_1119_STANDARD_FIELDS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HSMS_1119_STANDARD_FIELDS-VALID_TO, sy-vline,
WA_HSMS_1119_STANDARD_FIELDS-CHANG_NO, sy-vline,
WA_HSMS_1119_STANDARD_FIELDS-DEL_IND, sy-vline,
WA_HSMS_1119_STANDARD_FIELDS-CREATED_ON, sy-vline,
WA_HSMS_1119_STANDARD_FIELDS-CREATED_BY, sy-vline,
WA_HSMS_1119_STANDARD_FIELDS-CHANGD_ON, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HSMS_1119_STANDARD_FIELDS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HSMS_1119_STANDARD_FIELDS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HSMS_1119_STANDARD_FIELDS INTO WA_HSMS_1119_STANDARD_FIELDS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CHNGSTATUS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HSMS_1119_STANDARD_FIELDS-CHNGSTATUS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HSMS_1119_STANDARD_FIELDS-CHNGSTATUS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CHANG_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HSMS_1119_STANDARD_FIELDS-CHANG_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HSMS_1119_STANDARD_FIELDS-CHANG_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DATA_PROV CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HSMS_1119_STANDARD_FIELDS-DATA_PROV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HSMS_1119_STANDARD_FIELDS-DATA_PROV.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HSMS_1119_STANDARD_FIELDS_STR,
FUNCTION TYPE STRING,
CLIENT TYPE STRING,
RECORD_NO TYPE STRING,
CHNGSTATUS TYPE STRING,
VALID_FROM TYPE STRING,
VALID_TO TYPE STRING,
CHANG_NO TYPE STRING,
DEL_IND TYPE STRING,
CREATED_ON TYPE STRING,
CREATED_BY TYPE STRING,
CHANGD_ON TYPE STRING,
CHANGD_BY TYPE STRING,
DATAORIGIN TYPE STRING,
DATA_PROV TYPE STRING,
RECNO_ROOT TYPE STRING,END OF T_EKKO_STR. DATA: WA_HSMS_1119_STANDARD_FIELDS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HSMS_1119_STANDARD_FIELDS_STR-FUNCTION sy-vline
WA_HSMS_1119_STANDARD_FIELDS_STR-CLIENT sy-vline
WA_HSMS_1119_STANDARD_FIELDS_STR-RECORD_NO sy-vline
WA_HSMS_1119_STANDARD_FIELDS_STR-CHNGSTATUS sy-vline
WA_HSMS_1119_STANDARD_FIELDS_STR-VALID_FROM sy-vline
WA_HSMS_1119_STANDARD_FIELDS_STR-VALID_TO sy-vline
WA_HSMS_1119_STANDARD_FIELDS_STR-CHANG_NO sy-vline
WA_HSMS_1119_STANDARD_FIELDS_STR-DEL_IND sy-vline
WA_HSMS_1119_STANDARD_FIELDS_STR-CREATED_ON sy-vline
WA_HSMS_1119_STANDARD_FIELDS_STR-CREATED_BY sy-vline
WA_HSMS_1119_STANDARD_FIELDS_STR-CHANGD_ON sy-vline
WA_HSMS_1119_STANDARD_FIELDS_STR-CHANGD_BY sy-vline
WA_HSMS_1119_STANDARD_FIELDS_STR-DATAORIGIN sy-vline
WA_HSMS_1119_STANDARD_FIELDS_STR-DATA_PROV sy-vline
WA_HSMS_1119_STANDARD_FIELDS_STR-RECNO_ROOT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.