ABAP Select data from SAP table HRWPC_S_CP_BUDINFO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HRWPC_S_CP_BUDINFO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HRWPC_S_CP_BUDINFO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HRWPC_S_CP_BUDINFO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HRWPC_S_CP_BUDINFO TYPE STANDARD TABLE OF HRWPC_S_CP_BUDINFO,
      WA_HRWPC_S_CP_BUDINFO TYPE HRWPC_S_CP_BUDINFO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HRWPC_S_CP_BUDINFO> TYPE HRWPC_S_CP_BUDINFO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HRWPC_S_CP_BUDINFO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HRWPC_S_CP_BUDINFO
  INTO TABLE IT_HRWPC_S_CP_BUDINFO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HRWPC_S_CP_BUDINFO
*  INTO TABLE @DATA(IT_HRWPC_S_CP_BUDINFO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HRWPC_S_CP_BUDINFO INDEX 1 INTO DATA(WA_HRWPC_S_CP_BUDINFO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HRWPC_S_CP_BUDINFO ASSIGNING <HRWPC_S_CP_BUDINFO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HRWPC_S_CP_BUDINFO>-PERNR = 1.
<HRWPC_S_CP_BUDINFO>-BUTYP = 1.
<HRWPC_S_CP_BUDINFO>-PLVAR = 1.
<HRWPC_S_CP_BUDINFO>-OTYPE = 1.
<HRWPC_S_CP_BUDINFO>-BUDID = 1.
ENDLOOP.

LOOP AT IT_HRWPC_S_CP_BUDINFO INTO WA_HRWPC_S_CP_BUDINFO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HRWPC_S_CP_BUDINFO-BUDBEG, sy-vline,
WA_HRWPC_S_CP_BUDINFO-BUDEND, sy-vline,
WA_HRWPC_S_CP_BUDINFO-BUDLOCK, sy-vline,
WA_HRWPC_S_CP_BUDINFO-BUDSHORT, sy-vline,
WA_HRWPC_S_CP_BUDINFO-ORGID, sy-vline,
WA_HRWPC_S_CP_BUDINFO-BEGDA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HRWPC_S_CP_BUDINFO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HRWPC_S_CP_BUDINFO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HRWPC_S_CP_BUDINFO INTO WA_HRWPC_S_CP_BUDINFO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HRWPC_S_CP_BUDINFO_STR,
PERNR TYPE STRING,
BUTYP TYPE STRING,
PLVAR TYPE STRING,
OTYPE TYPE STRING,
BUDID TYPE STRING,
BUDBEG TYPE STRING,
BUDEND TYPE STRING,
BUDLOCK TYPE STRING,
BUDSHORT TYPE STRING,
ORGID TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
ORGSHORT TYPE STRING,
BUDGET TYPE STRING,
ALLOC TYPE STRING,
ALLOC_TOTAL TYPE STRING,
ALLOC_NEW TYPE STRING,
ALLOC_TOTAL_NEW TYPE STRING,
BETRG TYPE STRING,
REST TYPE STRING,
WAERS TYPE STRING,
AMNT_BUDGET TYPE STRING,
AMNT_ALLOC TYPE STRING,
AMNT_ALLOC_TOTAL TYPE STRING,
AMNT_ALLOC_NEW TYPE STRING,
AMNT_ALLOC_TOTAL_NEW TYPE STRING,
AMNT_BETRG TYPE STRING,
AMNT_REST TYPE STRING,
AMNT_BUGRU TYPE STRING,END OF T_EKKO_STR. DATA: WA_HRWPC_S_CP_BUDINFO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-PERNR sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-BUTYP sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-PLVAR sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-OTYPE sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-BUDID sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-BUDBEG sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-BUDEND sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-BUDLOCK sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-BUDSHORT sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-ORGID sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-BEGDA sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-ENDDA sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-ORGSHORT sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-BUDGET sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-ALLOC sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-ALLOC_TOTAL sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-ALLOC_NEW sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-ALLOC_TOTAL_NEW sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-BETRG sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-REST sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-WAERS sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-AMNT_BUDGET sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-AMNT_ALLOC sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-AMNT_ALLOC_TOTAL sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-AMNT_ALLOC_NEW sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-AMNT_ALLOC_TOTAL_NEW sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-AMNT_BETRG sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-AMNT_REST sy-vline
WA_HRWPC_S_CP_BUDINFO_STR-AMNT_BUGRU sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.