ABAP Select data from SAP table HRPY_PCC_TR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HRPY_PCC_TR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HRPY_PCC_TR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HRPY_PCC_TR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HRPY_PCC_TR TYPE STANDARD TABLE OF HRPY_PCC_TR,
      WA_HRPY_PCC_TR TYPE HRPY_PCC_TR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HRPY_PCC_TR> TYPE HRPY_PCC_TR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HRPY_PCC_TR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HRPY_PCC_TR
  INTO TABLE IT_HRPY_PCC_TR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HRPY_PCC_TR
*  INTO TABLE @DATA(IT_HRPY_PCC_TR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HRPY_PCC_TR INDEX 1 INTO DATA(WA_HRPY_PCC_TR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HRPY_PCC_TR ASSIGNING <HRPY_PCC_TR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HRPY_PCC_TR>-MANDT = 1.
<HRPY_PCC_TR>-DCT_TPY_ID = 1.
<HRPY_PCC_TR>-PERNR = 1.
<HRPY_PCC_TR>-SEQNR = 1.
<HRPY_PCC_TR>-IS_TPY = 1.
ENDLOOP.

LOOP AT IT_HRPY_PCC_TR INTO WA_HRPY_PCC_TR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HRPY_PCC_TR-ABKRS, sy-vline,
WA_HRPY_PCC_TR-FPPER, sy-vline,
WA_HRPY_PCC_TR-FPBEG, sy-vline,
WA_HRPY_PCC_TR-FPEND, sy-vline,
WA_HRPY_PCC_TR-IABKRS, sy-vline,
WA_HRPY_PCC_TR-IPERM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HRPY_PCC_TR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HRPY_PCC_TR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HRPY_PCC_TR INTO WA_HRPY_PCC_TR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HRPY_PCC_TR_STR,
MANDT TYPE STRING,
DCT_TPY_ID TYPE STRING,
PERNR TYPE STRING,
SEQNR TYPE STRING,
IS_TPY TYPE STRING,
ABKRS TYPE STRING,
FPPER TYPE STRING,
FPBEG TYPE STRING,
FPEND TYPE STRING,
IABKRS TYPE STRING,
IPERM TYPE STRING,
INPER TYPE STRING,
IPEND TYPE STRING,
JUPER TYPE STRING,
SRTZA TYPE STRING,
PAYTY TYPE STRING,
PAYID TYPE STRING,
VOID TYPE STRING,
BONDT TYPE STRING,
PERMO TYPE STRING,
PAYDT TYPE STRING,
INPTY TYPE STRING,
INPID TYPE STRING,
OCRSN TYPE STRING,
INOCR TYPE STRING,
MOLGA TYPE STRING,
CALCD TYPE STRING,
PERIOD_KEY TYPE STRING,END OF T_EKKO_STR. DATA: WA_HRPY_PCC_TR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HRPY_PCC_TR_STR-MANDT sy-vline
WA_HRPY_PCC_TR_STR-DCT_TPY_ID sy-vline
WA_HRPY_PCC_TR_STR-PERNR sy-vline
WA_HRPY_PCC_TR_STR-SEQNR sy-vline
WA_HRPY_PCC_TR_STR-IS_TPY sy-vline
WA_HRPY_PCC_TR_STR-ABKRS sy-vline
WA_HRPY_PCC_TR_STR-FPPER sy-vline
WA_HRPY_PCC_TR_STR-FPBEG sy-vline
WA_HRPY_PCC_TR_STR-FPEND sy-vline
WA_HRPY_PCC_TR_STR-IABKRS sy-vline
WA_HRPY_PCC_TR_STR-IPERM sy-vline
WA_HRPY_PCC_TR_STR-INPER sy-vline
WA_HRPY_PCC_TR_STR-IPEND sy-vline
WA_HRPY_PCC_TR_STR-JUPER sy-vline
WA_HRPY_PCC_TR_STR-SRTZA sy-vline
WA_HRPY_PCC_TR_STR-PAYTY sy-vline
WA_HRPY_PCC_TR_STR-PAYID sy-vline
WA_HRPY_PCC_TR_STR-VOID sy-vline
WA_HRPY_PCC_TR_STR-BONDT sy-vline
WA_HRPY_PCC_TR_STR-PERMO sy-vline
WA_HRPY_PCC_TR_STR-PAYDT sy-vline
WA_HRPY_PCC_TR_STR-INPTY sy-vline
WA_HRPY_PCC_TR_STR-INPID sy-vline
WA_HRPY_PCC_TR_STR-OCRSN sy-vline
WA_HRPY_PCC_TR_STR-INOCR sy-vline
WA_HRPY_PCC_TR_STR-MOLGA sy-vline
WA_HRPY_PCC_TR_STR-CALCD sy-vline
WA_HRPY_PCC_TR_STR-PERIOD_KEY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.