ABAP Select data from SAP table HRPP_WSRTAX1U38 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HRPP_WSRTAX1U38 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HRPP_WSRTAX1U38. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HRPP_WSRTAX1U38 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HRPP_WSRTAX1U38 TYPE STANDARD TABLE OF HRPP_WSRTAX1U38,
      WA_HRPP_WSRTAX1U38 TYPE HRPP_WSRTAX1U38,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HRPP_WSRTAX1U38> TYPE HRPP_WSRTAX1U38.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HRPP_WSRTAX1U38.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HRPP_WSRTAX1U38
  INTO TABLE IT_HRPP_WSRTAX1U38.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HRPP_WSRTAX1U38
*  INTO TABLE @DATA(IT_HRPP_WSRTAX1U382).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HRPP_WSRTAX1U38 INDEX 1 INTO DATA(WA_HRPP_WSRTAX1U382).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HRPP_WSRTAX1U38 ASSIGNING <HRPP_WSRTAX1U38>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HRPP_WSRTAX1U38>-CONTROLLER = 1.
<HRPP_WSRTAX1U38>-POSNR = 1.
<HRPP_WSRTAX1U38>-BUKRS = 1.
<HRPP_WSRTAX1U38>-MWSKZ = 1.
<HRPP_WSRTAX1U38>-TXJCD = 1.
ENDLOOP.

LOOP AT IT_HRPP_WSRTAX1U38 INTO WA_HRPP_WSRTAX1U38.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HRPP_WSRTAX1U38-WAERS, sy-vline,
WA_HRPP_WSRTAX1U38-BLDAT, sy-vline,
WA_HRPP_WSRTAX1U38-BUDAT, sy-vline,
WA_HRPP_WSRTAX1U38-WRBTR, sy-vline,
WA_HRPP_WSRTAX1U38-FWSTE, sy-vline,
WA_HRPP_WSRTAX1U38-MSATZ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HRPP_WSRTAX1U38 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HRPP_WSRTAX1U38 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HRPP_WSRTAX1U38 INTO WA_HRPP_WSRTAX1U38. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HRPP_WSRTAX1U38_STR,
CONTROLLER TYPE STRING,
POSNR TYPE STRING,
BUKRS TYPE STRING,
MWSKZ TYPE STRING,
TXJCD TYPE STRING,
WAERS TYPE STRING,
BLDAT TYPE STRING,
BUDAT TYPE STRING,
WRBTR TYPE STRING,
FWSTE TYPE STRING,
MSATZ TYPE STRING,
FWBAS TYPE STRING,
HKONT TYPE STRING,
KTOSL TYPE STRING,
ERROR TYPE STRING,
STGRP TYPE STRING,
STAZF TYPE STRING,
STBKZ TYPE STRING,
STNSK TYPE STRING,
KSCHL TYPE STRING,
TXDAT TYPE STRING,
TXJCD_DEEP TYPE STRING,
TXJLV TYPE STRING,END OF T_EKKO_STR. DATA: WA_HRPP_WSRTAX1U38_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HRPP_WSRTAX1U38_STR-CONTROLLER sy-vline
WA_HRPP_WSRTAX1U38_STR-POSNR sy-vline
WA_HRPP_WSRTAX1U38_STR-BUKRS sy-vline
WA_HRPP_WSRTAX1U38_STR-MWSKZ sy-vline
WA_HRPP_WSRTAX1U38_STR-TXJCD sy-vline
WA_HRPP_WSRTAX1U38_STR-WAERS sy-vline
WA_HRPP_WSRTAX1U38_STR-BLDAT sy-vline
WA_HRPP_WSRTAX1U38_STR-BUDAT sy-vline
WA_HRPP_WSRTAX1U38_STR-WRBTR sy-vline
WA_HRPP_WSRTAX1U38_STR-FWSTE sy-vline
WA_HRPP_WSRTAX1U38_STR-MSATZ sy-vline
WA_HRPP_WSRTAX1U38_STR-FWBAS sy-vline
WA_HRPP_WSRTAX1U38_STR-HKONT sy-vline
WA_HRPP_WSRTAX1U38_STR-KTOSL sy-vline
WA_HRPP_WSRTAX1U38_STR-ERROR sy-vline
WA_HRPP_WSRTAX1U38_STR-STGRP sy-vline
WA_HRPP_WSRTAX1U38_STR-STAZF sy-vline
WA_HRPP_WSRTAX1U38_STR-STBKZ sy-vline
WA_HRPP_WSRTAX1U38_STR-STNSK sy-vline
WA_HRPP_WSRTAX1U38_STR-KSCHL sy-vline
WA_HRPP_WSRTAX1U38_STR-TXDAT sy-vline
WA_HRPP_WSRTAX1U38_STR-TXJCD_DEEP sy-vline
WA_HRPP_WSRTAX1U38_STR-TXJLV sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.