ABAP Select data from SAP table HRPE_PROFQB into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HRPE_PROFQB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HRPE_PROFQB. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HRPE_PROFQB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HRPE_PROFQB TYPE STANDARD TABLE OF HRPE_PROFQB,
      WA_HRPE_PROFQB TYPE HRPE_PROFQB,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HRPE_PROFQB> TYPE HRPE_PROFQB.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HRPE_PROFQB.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HRPE_PROFQB
  INTO TABLE IT_HRPE_PROFQB.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HRPE_PROFQB
*  INTO TABLE @DATA(IT_HRPE_PROFQB2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HRPE_PROFQB INDEX 1 INTO DATA(WA_HRPE_PROFQB2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HRPE_PROFQB ASSIGNING <HRPE_PROFQB>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HRPE_PROFQB>-PLVAR = 1.
<HRPE_PROFQB>-OTYPE = 1.
<HRPE_PROFQB>-SOBID = 1.
<HRPE_PROFQB>-SHORT = 1.
<HRPE_PROFQB>-STEXT = 1.
ENDLOOP.

LOOP AT IT_HRPE_PROFQB INTO WA_HRPE_PROFQB.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HRPE_PROFQB-MARK_X, sy-vline,
WA_HRPE_PROFQB-TTYPE, sy-vline,
WA_HRPE_PROFQB-TBJID, sy-vline,
WA_HRPE_PROFQB-SBEGD, sy-vline,
WA_HRPE_PROFQB-SENDD, sy-vline,
WA_HRPE_PROFQB-VBEGD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HRPE_PROFQB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HRPE_PROFQB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HRPE_PROFQB INTO WA_HRPE_PROFQB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HRPE_PROFQB_STR,
PLVAR TYPE STRING,
OTYPE TYPE STRING,
SOBID TYPE STRING,
SHORT TYPE STRING,
STEXT TYPE STRING,
MARK_X TYPE STRING,
TTYPE TYPE STRING,
TBJID TYPE STRING,
SBEGD TYPE STRING,
SENDD TYPE STRING,
VBEGD TYPE STRING,
VENDD TYPE STRING,
ISTAT TYPE STRING,
NOTE TYPE STRING,
TSHORT TYPE STRING,
TTEXT TYPE STRING,
PROFCY TYPE STRING,
PROFCY2 TYPE STRING,
ESSENTIAL TYPE STRING,
NOT_RATED TYPE STRING,
INHER_TYPE TYPE STRING,
INHER_ID TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
CLASS_ID TYPE STRING,
CLASS_TEXT TYPE STRING,
SCALE_ID TYPE STRING,
SCALE_TEXT TYPE STRING,
PROFC_TEXT TYPE STRING,
PROF2_TEXT TYPE STRING,
PROZT TYPE STRING,END OF T_EKKO_STR. DATA: WA_HRPE_PROFQB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HRPE_PROFQB_STR-PLVAR sy-vline
WA_HRPE_PROFQB_STR-OTYPE sy-vline
WA_HRPE_PROFQB_STR-SOBID sy-vline
WA_HRPE_PROFQB_STR-SHORT sy-vline
WA_HRPE_PROFQB_STR-STEXT sy-vline
WA_HRPE_PROFQB_STR-MARK_X sy-vline
WA_HRPE_PROFQB_STR-TTYPE sy-vline
WA_HRPE_PROFQB_STR-TBJID sy-vline
WA_HRPE_PROFQB_STR-SBEGD sy-vline
WA_HRPE_PROFQB_STR-SENDD sy-vline
WA_HRPE_PROFQB_STR-VBEGD sy-vline
WA_HRPE_PROFQB_STR-VENDD sy-vline
WA_HRPE_PROFQB_STR-ISTAT sy-vline
WA_HRPE_PROFQB_STR-NOTE sy-vline
WA_HRPE_PROFQB_STR-TSHORT sy-vline
WA_HRPE_PROFQB_STR-TTEXT sy-vline
WA_HRPE_PROFQB_STR-PROFCY sy-vline
WA_HRPE_PROFQB_STR-PROFCY2 sy-vline
WA_HRPE_PROFQB_STR-ESSENTIAL sy-vline
WA_HRPE_PROFQB_STR-NOT_RATED sy-vline
WA_HRPE_PROFQB_STR-INHER_TYPE sy-vline
WA_HRPE_PROFQB_STR-INHER_ID sy-vline
WA_HRPE_PROFQB_STR-AEDTM sy-vline
WA_HRPE_PROFQB_STR-UNAME sy-vline
WA_HRPE_PROFQB_STR-CLASS_ID sy-vline
WA_HRPE_PROFQB_STR-CLASS_TEXT sy-vline
WA_HRPE_PROFQB_STR-SCALE_ID sy-vline
WA_HRPE_PROFQB_STR-SCALE_TEXT sy-vline
WA_HRPE_PROFQB_STR-PROFC_TEXT sy-vline
WA_HRPE_PROFQB_STR-PROF2_TEXT sy-vline
WA_HRPE_PROFQB_STR-PROZT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.