ABAP Select data from SAP table HRPADUA_SIPR_1PRT_TAB into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HRPADUA_SIPR_1PRT_TAB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HRPADUA_SIPR_1PRT_TAB. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HRPADUA_SIPR_1PRT_TAB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HRPADUA_SIPR_1PRT_TAB TYPE STANDARD TABLE OF HRPADUA_SIPR_1PRT_TAB,
      WA_HRPADUA_SIPR_1PRT_TAB TYPE HRPADUA_SIPR_1PRT_TAB,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HRPADUA_SIPR_1PRT_TAB> TYPE HRPADUA_SIPR_1PRT_TAB.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HRPADUA_SIPR_1PRT_TAB.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HRPADUA_SIPR_1PRT_TAB
  INTO TABLE IT_HRPADUA_SIPR_1PRT_TAB.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HRPADUA_SIPR_1PRT_TAB
*  INTO TABLE @DATA(IT_HRPADUA_SIPR_1PRT_TAB2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HRPADUA_SIPR_1PRT_TAB INDEX 1 INTO DATA(WA_HRPADUA_SIPR_1PRT_TAB2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HRPADUA_SIPR_1PRT_TAB ASSIGNING <HRPADUA_SIPR_1PRT_TAB>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HRPADUA_SIPR_1PRT_TAB>-T2R01 = 1.
<HRPADUA_SIPR_1PRT_TAB>-NACHN = 1.
<HRPADUA_SIPR_1PRT_TAB>-VORNA = 1.
<HRPADUA_SIPR_1PRT_TAB>-MIDNM = 1.
<HRPADUA_SIPR_1PRT_TAB>-IDDOC = 1.
ENDLOOP.

LOOP AT IT_HRPADUA_SIPR_1PRT_TAB INTO WA_HRPADUA_SIPR_1PRT_TAB.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HRPADUA_SIPR_1PRT_TAB-OCCTY, sy-vline,
WA_HRPADUA_SIPR_1PRT_TAB-SLSER, sy-vline,
WA_HRPADUA_SIPR_1PRT_TAB-SLNUM, sy-vline,
WA_HRPADUA_SIPR_1PRT_TAB-SLKIN, sy-vline,
WA_HRPADUA_SIPR_1PRT_TAB-INRES, sy-vline,
WA_HRPADUA_SIPR_1PRT_TAB-INSDT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HRPADUA_SIPR_1PRT_TAB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HRPADUA_SIPR_1PRT_TAB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HRPADUA_SIPR_1PRT_TAB INTO WA_HRPADUA_SIPR_1PRT_TAB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HRPADUA_SIPR_1PRT_TAB_STR,
T2R01 TYPE STRING,
NACHN TYPE STRING,
VORNA TYPE STRING,
MIDNM TYPE STRING,
IDDOC TYPE STRING,
OCCTY TYPE STRING,
SLSER TYPE STRING,
SLNUM TYPE STRING,
SLKIN TYPE STRING,
INRES TYPE STRING,
INSDT TYPE STRING,
INEDT TYPE STRING,
INCDT TYPE STRING,
INCDF TYPE STRING,
INCST TYPE STRING,
INCSF TYPE STRING,
INCDC TYPE STRING,
INCSC TYPE STRING,
CHDOC TYPE STRING,
DMSEK TYPE STRING,
SENIM TYPE STRING,
SEN12 TYPE STRING,
TCOST TYPE STRING,
INSDX TYPE STRING,
INEDX TYPE STRING,
RNMAT TYPE STRING,END OF T_EKKO_STR. DATA: WA_HRPADUA_SIPR_1PRT_TAB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-T2R01 sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-NACHN sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-VORNA sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-MIDNM sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-IDDOC sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-OCCTY sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-SLSER sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-SLNUM sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-SLKIN sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-INRES sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-INSDT sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-INEDT sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-INCDT sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-INCDF sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-INCST sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-INCSF sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-INCDC sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-INCSC sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-CHDOC sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-DMSEK sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-SENIM sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-SEN12 sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-TCOST sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-INSDX sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-INEDX sy-vline
WA_HRPADUA_SIPR_1PRT_TAB_STR-RNMAT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.