ABAP Select data from SAP table HRP1812 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HRP1812 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HRP1812. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HRP1812 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HRP1812 TYPE STANDARD TABLE OF HRP1812,
      WA_HRP1812 TYPE HRP1812,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HRP1812> TYPE HRP1812.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HRP1812.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HRP1812
  INTO TABLE IT_HRP1812.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HRP1812
*  INTO TABLE @DATA(IT_HRP18122).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HRP1812 INDEX 1 INTO DATA(WA_HRP18122).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HRP1812 ASSIGNING <HRP1812>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HRP1812>-MANDT = 1.
<HRP1812>-PLVAR = 1.
<HRP1812>-OTYPE = 1.
<HRP1812>-OBJID = 1.
<HRP1812>-SUBTY = 1.
ENDLOOP.

LOOP AT IT_HRP1812 INTO WA_HRP1812.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HRP1812-ISTAT, sy-vline,
WA_HRP1812-BEGDA, sy-vline,
WA_HRP1812-ENDDA, sy-vline,
WA_HRP1812-VARYF, sy-vline,
WA_HRP1812-SEQNR, sy-vline,
WA_HRP1812-INFTY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HRP1812 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HRP1812 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HRP1812 INTO WA_HRP1812. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HRP1812_STR,
MANDT TYPE STRING,
PLVAR TYPE STRING,
OTYPE TYPE STRING,
OBJID TYPE STRING,
SUBTY TYPE STRING,
ISTAT TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
VARYF TYPE STRING,
SEQNR TYPE STRING,
INFTY TYPE STRING,
OTJID TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
REASN TYPE STRING,
HISTO TYPE STRING,
ITXNR TYPE STRING,
VAL_P_DESIGN TYPE STRING,
VAL_P_REMED TYPE STRING,
ROLE_ASSIGN_STAT TYPE STRING,END OF T_EKKO_STR. DATA: WA_HRP1812_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HRP1812_STR-MANDT sy-vline
WA_HRP1812_STR-PLVAR sy-vline
WA_HRP1812_STR-OTYPE sy-vline
WA_HRP1812_STR-OBJID sy-vline
WA_HRP1812_STR-SUBTY sy-vline
WA_HRP1812_STR-ISTAT sy-vline
WA_HRP1812_STR-BEGDA sy-vline
WA_HRP1812_STR-ENDDA sy-vline
WA_HRP1812_STR-VARYF sy-vline
WA_HRP1812_STR-SEQNR sy-vline
WA_HRP1812_STR-INFTY sy-vline
WA_HRP1812_STR-OTJID sy-vline
WA_HRP1812_STR-AEDTM sy-vline
WA_HRP1812_STR-UNAME sy-vline
WA_HRP1812_STR-REASN sy-vline
WA_HRP1812_STR-HISTO sy-vline
WA_HRP1812_STR-ITXNR sy-vline
WA_HRP1812_STR-VAL_P_DESIGN sy-vline
WA_HRP1812_STR-VAL_P_REMED sy-vline
WA_HRP1812_STR-ROLE_ASSIGN_STAT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.