ABAP Select data from SAP table HRP1005 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HRP1005 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HRP1005. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HRP1005 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HRP1005 TYPE STANDARD TABLE OF HRP1005,
      WA_HRP1005 TYPE HRP1005,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HRP1005> TYPE HRP1005.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HRP1005.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HRP1005
  INTO TABLE IT_HRP1005.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HRP1005
*  INTO TABLE @DATA(IT_HRP10052).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HRP1005 INDEX 1 INTO DATA(WA_HRP10052).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HRP1005 ASSIGNING <HRP1005>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HRP1005>-MANDT = 1.
<HRP1005>-PLVAR = 1.
<HRP1005>-OTYPE = 1.
<HRP1005>-OBJID = 1.
<HRP1005>-SUBTY = 1.
ENDLOOP.

LOOP AT IT_HRP1005 INTO WA_HRP1005.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HRP1005-ISTAT, sy-vline,
WA_HRP1005-BEGDA, sy-vline,
WA_HRP1005-ENDDA, sy-vline,
WA_HRP1005-VARYF, sy-vline,
WA_HRP1005-SEQNR, sy-vline,
WA_HRP1005-INFTY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HRP1005 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HRP1005 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HRP1005 INTO WA_HRP1005. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HRP1005_STR,
MANDT TYPE STRING,
PLVAR TYPE STRING,
OTYPE TYPE STRING,
OBJID TYPE STRING,
SUBTY TYPE STRING,
ISTAT TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
VARYF TYPE STRING,
SEQNR TYPE STRING,
INFTY TYPE STRING,
OTJID TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
REASN TYPE STRING,
HISTO TYPE STRING,
ITXNR TYPE STRING,
MOLGA TYPE STRING,
TRFAR TYPE STRING,
TRFGB TYPE STRING,
TRFKZ TYPE STRING,
TRFG1 TYPE STRING,
TRFG2 TYPE STRING,
TRFS1 TYPE STRING,
TRFS2 TYPE STRING,
BUDG1 TYPE STRING,
BUDG2 TYPE STRING,
CURCY TYPE STRING,
MIDPT TYPE STRING,
FREQU TYPE STRING,
CPIND TYPE STRING,
CPMIN TYPE STRING,
CPMAX TYPE STRING,END OF T_EKKO_STR. DATA: WA_HRP1005_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HRP1005_STR-MANDT sy-vline
WA_HRP1005_STR-PLVAR sy-vline
WA_HRP1005_STR-OTYPE sy-vline
WA_HRP1005_STR-OBJID sy-vline
WA_HRP1005_STR-SUBTY sy-vline
WA_HRP1005_STR-ISTAT sy-vline
WA_HRP1005_STR-BEGDA sy-vline
WA_HRP1005_STR-ENDDA sy-vline
WA_HRP1005_STR-VARYF sy-vline
WA_HRP1005_STR-SEQNR sy-vline
WA_HRP1005_STR-INFTY sy-vline
WA_HRP1005_STR-OTJID sy-vline
WA_HRP1005_STR-AEDTM sy-vline
WA_HRP1005_STR-UNAME sy-vline
WA_HRP1005_STR-REASN sy-vline
WA_HRP1005_STR-HISTO sy-vline
WA_HRP1005_STR-ITXNR sy-vline
WA_HRP1005_STR-MOLGA sy-vline
WA_HRP1005_STR-TRFAR sy-vline
WA_HRP1005_STR-TRFGB sy-vline
WA_HRP1005_STR-TRFKZ sy-vline
WA_HRP1005_STR-TRFG1 sy-vline
WA_HRP1005_STR-TRFG2 sy-vline
WA_HRP1005_STR-TRFS1 sy-vline
WA_HRP1005_STR-TRFS2 sy-vline
WA_HRP1005_STR-BUDG1 sy-vline
WA_HRP1005_STR-BUDG2 sy-vline
WA_HRP1005_STR-CURCY sy-vline
WA_HRP1005_STR-MIDPT sy-vline
WA_HRP1005_STR-FREQU sy-vline
WA_HRP1005_STR-CPIND sy-vline
WA_HRP1005_STR-CPMIN sy-vline
WA_HRP1005_STR-CPMAX sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.