ABAP Select data from SAP table HRI5010 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HRI5010 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HRI5010. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HRI5010 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HRI5010 TYPE STANDARD TABLE OF HRI5010,
      WA_HRI5010 TYPE HRI5010,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HRI5010> TYPE HRI5010.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HRI5010.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HRI5010
  INTO TABLE IT_HRI5010.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HRI5010
*  INTO TABLE @DATA(IT_HRI50102).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HRI5010 INDEX 1 INTO DATA(WA_HRI50102).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HRI5010 ASSIGNING <HRI5010>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HRI5010>-CITEM = 1.
<HRI5010>-DC_INTERFACE = 1.
<HRI5010>-MOLGA = 1.
<HRI5010>-BETRG = 1.
<HRI5010>-WAERS = 1.
ENDLOOP.

LOOP AT IT_HRI5010 INTO WA_HRI5010.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HRI5010-ANZHL, sy-vline,
WA_HRI5010-UNIT, sy-vline,
WA_HRI5010-RATE, sy-vline,
WA_HRI5010-PERIO, sy-vline,
WA_HRI5010-DIFFCA_BUKRS, sy-vline,
WA_HRI5010-DIFFCA_KOKRS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HRI5010 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HRI5010 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HRI5010 INTO WA_HRI5010. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field DIFFCA_KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HRI5010-DIFFCA_KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HRI5010-DIFFCA_KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DIFFCA_AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HRI5010-DIFFCA_AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HRI5010-DIFFCA_AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field DIFFCA_POSNR CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_HRI5010-DIFFCA_POSNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HRI5010-DIFFCA_POSNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DIFFCA_GRANT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HRI5010-DIFFCA_GRANT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HRI5010-DIFFCA_GRANT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HRI5010_STR,
CITEM TYPE STRING,
DC_INTERFACE TYPE STRING,
MOLGA TYPE STRING,
BETRG TYPE STRING,
WAERS TYPE STRING,
ANZHL TYPE STRING,
UNIT TYPE STRING,
RATE TYPE STRING,
PERIO TYPE STRING,
DIFFCA_BUKRS TYPE STRING,
DIFFCA_KOKRS TYPE STRING,
DIFFCA_KOSTL TYPE STRING,
DIFFCA_AUFNR TYPE STRING,
DIFFCA_POSNR TYPE STRING,
DIFFCA_FONDS TYPE STRING,
DIFFCA_FKBER TYPE STRING,
DIFFCA_GRANT TYPE STRING,
DIFFCA_FISTL TYPE STRING,
DIFFCA_FIKRS TYPE STRING,
BUDGET_PD TYPE STRING,END OF T_EKKO_STR. DATA: WA_HRI5010_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HRI5010_STR-CITEM sy-vline
WA_HRI5010_STR-DC_INTERFACE sy-vline
WA_HRI5010_STR-MOLGA sy-vline
WA_HRI5010_STR-BETRG sy-vline
WA_HRI5010_STR-WAERS sy-vline
WA_HRI5010_STR-ANZHL sy-vline
WA_HRI5010_STR-UNIT sy-vline
WA_HRI5010_STR-RATE sy-vline
WA_HRI5010_STR-PERIO sy-vline
WA_HRI5010_STR-DIFFCA_BUKRS sy-vline
WA_HRI5010_STR-DIFFCA_KOKRS sy-vline
WA_HRI5010_STR-DIFFCA_KOSTL sy-vline
WA_HRI5010_STR-DIFFCA_AUFNR sy-vline
WA_HRI5010_STR-DIFFCA_POSNR sy-vline
WA_HRI5010_STR-DIFFCA_FONDS sy-vline
WA_HRI5010_STR-DIFFCA_FKBER sy-vline
WA_HRI5010_STR-DIFFCA_GRANT sy-vline
WA_HRI5010_STR-DIFFCA_FISTL sy-vline
WA_HRI5010_STR-DIFFCA_FIKRS sy-vline
WA_HRI5010_STR-BUDGET_PD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.