ABAP Select data from SAP table HRFPM_S_OM_HOLDER_ALV into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HRFPM_S_OM_HOLDER_ALV table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HRFPM_S_OM_HOLDER_ALV. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HRFPM_S_OM_HOLDER_ALV table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HRFPM_S_OM_HOLDER_ALV TYPE STANDARD TABLE OF HRFPM_S_OM_HOLDER_ALV,
      WA_HRFPM_S_OM_HOLDER_ALV TYPE HRFPM_S_OM_HOLDER_ALV,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HRFPM_S_OM_HOLDER_ALV> TYPE HRFPM_S_OM_HOLDER_ALV.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HRFPM_S_OM_HOLDER_ALV.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HRFPM_S_OM_HOLDER_ALV
  INTO TABLE IT_HRFPM_S_OM_HOLDER_ALV.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HRFPM_S_OM_HOLDER_ALV
*  INTO TABLE @DATA(IT_HRFPM_S_OM_HOLDER_ALV2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HRFPM_S_OM_HOLDER_ALV INDEX 1 INTO DATA(WA_HRFPM_S_OM_HOLDER_ALV2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HRFPM_S_OM_HOLDER_ALV ASSIGNING <HRFPM_S_OM_HOLDER_ALV>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HRFPM_S_OM_HOLDER_ALV>-BEGDA = 1.
<HRFPM_S_OM_HOLDER_ALV>-ENDDA = 1.
<HRFPM_S_OM_HOLDER_ALV>-PLVARFI = 1.
<HRFPM_S_OM_HOLDER_ALV>-OTYPEFI = 1.
<HRFPM_S_OM_HOLDER_ALV>-OBJIDFI = 1.
ENDLOOP.

LOOP AT IT_HRFPM_S_OM_HOLDER_ALV INTO WA_HRFPM_S_OM_HOLDER_ALV.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HRFPM_S_OM_HOLDER_ALV-PLVARBU, sy-vline,
WA_HRFPM_S_OM_HOLDER_ALV-OTYPEBU, sy-vline,
WA_HRFPM_S_OM_HOLDER_ALV-OBJIDBU, sy-vline,
WA_HRFPM_S_OM_HOLDER_ALV-VSEQNR, sy-vline,
WA_HRFPM_S_OM_HOLDER_ALV-SEQNR_FI, sy-vline,
WA_HRFPM_S_OM_HOLDER_ALV-SEQNR_BU, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HRFPM_S_OM_HOLDER_ALV you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HRFPM_S_OM_HOLDER_ALV TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HRFPM_S_OM_HOLDER_ALV INTO WA_HRFPM_S_OM_HOLDER_ALV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HRFPM_S_OM_HOLDER_ALV_STR,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
PLVARFI TYPE STRING,
OTYPEFI TYPE STRING,
OBJIDFI TYPE STRING,
PLVARBU TYPE STRING,
OTYPEBU TYPE STRING,
OBJIDBU TYPE STRING,
VSEQNR TYPE STRING,
SEQNR_FI TYPE STRING,
SEQNR_BU TYPE STRING,
SHORT TYPE STRING,
STEXT TYPE STRING,
REALO TYPE STRING,
PROZT TYPE STRING,
AMOUNT TYPE STRING,
BUGRU TYPE STRING,
UNAME TYPE STRING,
AEDTM TYPE STRING,END OF T_EKKO_STR. DATA: WA_HRFPM_S_OM_HOLDER_ALV_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HRFPM_S_OM_HOLDER_ALV_STR-BEGDA sy-vline
WA_HRFPM_S_OM_HOLDER_ALV_STR-ENDDA sy-vline
WA_HRFPM_S_OM_HOLDER_ALV_STR-PLVARFI sy-vline
WA_HRFPM_S_OM_HOLDER_ALV_STR-OTYPEFI sy-vline
WA_HRFPM_S_OM_HOLDER_ALV_STR-OBJIDFI sy-vline
WA_HRFPM_S_OM_HOLDER_ALV_STR-PLVARBU sy-vline
WA_HRFPM_S_OM_HOLDER_ALV_STR-OTYPEBU sy-vline
WA_HRFPM_S_OM_HOLDER_ALV_STR-OBJIDBU sy-vline
WA_HRFPM_S_OM_HOLDER_ALV_STR-VSEQNR sy-vline
WA_HRFPM_S_OM_HOLDER_ALV_STR-SEQNR_FI sy-vline
WA_HRFPM_S_OM_HOLDER_ALV_STR-SEQNR_BU sy-vline
WA_HRFPM_S_OM_HOLDER_ALV_STR-SHORT sy-vline
WA_HRFPM_S_OM_HOLDER_ALV_STR-STEXT sy-vline
WA_HRFPM_S_OM_HOLDER_ALV_STR-REALO sy-vline
WA_HRFPM_S_OM_HOLDER_ALV_STR-PROZT sy-vline
WA_HRFPM_S_OM_HOLDER_ALV_STR-AMOUNT sy-vline
WA_HRFPM_S_OM_HOLDER_ALV_STR-BUGRU sy-vline
WA_HRFPM_S_OM_HOLDER_ALV_STR-UNAME sy-vline
WA_HRFPM_S_OM_HOLDER_ALV_STR-AEDTM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.