ABAP Select data from SAP table HRECM00BW_IS_COMP_PROC_13 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HRECM00BW_IS_COMP_PROC_13 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HRECM00BW_IS_COMP_PROC_13. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HRECM00BW_IS_COMP_PROC_13 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HRECM00BW_IS_COMP_PROC_13 TYPE STANDARD TABLE OF HRECM00BW_IS_COMP_PROC_13,
      WA_HRECM00BW_IS_COMP_PROC_13 TYPE HRECM00BW_IS_COMP_PROC_13,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HRECM00BW_IS_COMP_PROC_13> TYPE HRECM00BW_IS_COMP_PROC_13.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HRECM00BW_IS_COMP_PROC_13.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HRECM00BW_IS_COMP_PROC_13
  INTO TABLE IT_HRECM00BW_IS_COMP_PROC_13.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HRECM00BW_IS_COMP_PROC_13
*  INTO TABLE @DATA(IT_HRECM00BW_IS_COMP_PROC_132).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HRECM00BW_IS_COMP_PROC_13 INDEX 1 INTO DATA(WA_HRECM00BW_IS_COMP_PROC_132).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HRECM00BW_IS_COMP_PROC_13 ASSIGNING <HRECM00BW_IS_COMP_PROC_13>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HRECM00BW_IS_COMP_PROC_13>-PERNR = 1.
<HRECM00BW_IS_COMP_PROC_13>-CITEM = 1.
<HRECM00BW_IS_COMP_PROC_13>-CREVI = 1.
<HRECM00BW_IS_COMP_PROC_13>-CPLAN = 1.
<HRECM00BW_IS_COMP_PROC_13>-EFFDT = 1.
ENDLOOP.

LOOP AT IT_HRECM00BW_IS_COMP_PROC_13 INTO WA_HRECM00BW_IS_COMP_PROC_13.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HRECM00BW_IS_COMP_PROC_13-SEQNR, sy-vline,
WA_HRECM00BW_IS_COMP_PROC_13-CSTAT, sy-vline,
WA_HRECM00BW_IS_COMP_PROC_13-CAREA, sy-vline,
WA_HRECM00BW_IS_COMP_PROC_13-CPAMT, sy-vline,
WA_HRECM00BW_IS_COMP_PROC_13-FREQU, sy-vline,
WA_HRECM00BW_IS_COMP_PROC_13-CPAMTYR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HRECM00BW_IS_COMP_PROC_13 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HRECM00BW_IS_COMP_PROC_13 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HRECM00BW_IS_COMP_PROC_13 INTO WA_HRECM00BW_IS_COMP_PROC_13. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HRECM00BW_IS_COMP_PROC_13_STR,
PERNR TYPE STRING,
CITEM TYPE STRING,
CREVI TYPE STRING,
CPLAN TYPE STRING,
EFFDT TYPE STRING,
SEQNR TYPE STRING,
CSTAT TYPE STRING,
CAREA TYPE STRING,
CPAMT TYPE STRING,
FREQU TYPE STRING,
CPAMTYR TYPE STRING,
CURRE TYPE STRING,
CPNUM TYPE STRING,
STKUN TYPE STRING,
DFAMT TYPE STRING,
DFAMTYR TYPE STRING,
MIAMT TYPE STRING,
MIAMTYR TYPE STRING,
MAAMT TYPE STRING,
MAAMTYR TYPE STRING,
DFNUM TYPE STRING,
MINUM TYPE STRING,
MANUM TYPE STRING,
BUDID TYPE STRING,
BDBEG TYPE STRING,
BSSAL TYPE STRING,
FIRSTPL_AMNT TYPE STRING,
FIRSTPL_AMNTYR TYPE STRING,
FIRSTPL_NUM TYPE STRING,
NEW_SALARY TYPE STRING,
CPAMT1 TYPE STRING,
CPAMTYR1 TYPE STRING,
CURRE1 TYPE STRING,
DFAMT1 TYPE STRING,
DFAMTYR1 TYPE STRING,
MIAMT1 TYPE STRING,
MIAMTYR1 TYPE STRING,
MAAMT1 TYPE STRING,
MAAMTYR1 TYPE STRING,
BSSAL1 TYPE STRING,
FIRSTPL_AMNT1 TYPE STRING,
FIRSTPL_AMNTYR1 TYPE STRING,
NEW_SALARY1 TYPE STRING,
CPNUM1 TYPE STRING,
STKUN1 TYPE STRING,
DFNUM1 TYPE STRING,
MINUM1 TYPE STRING,
MANUM1 TYPE STRING,
FIRSTPL_NUM1 TYPE STRING,END OF T_EKKO_STR. DATA: WA_HRECM00BW_IS_COMP_PROC_13_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-PERNR sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-CITEM sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-CREVI sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-CPLAN sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-EFFDT sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-SEQNR sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-CSTAT sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-CAREA sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-CPAMT sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-FREQU sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-CPAMTYR sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-CURRE sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-CPNUM sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-STKUN sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-DFAMT sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-DFAMTYR sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-MIAMT sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-MIAMTYR sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-MAAMT sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-MAAMTYR sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-DFNUM sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-MINUM sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-MANUM sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-BUDID sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-BDBEG sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-BSSAL sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-FIRSTPL_AMNT sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-FIRSTPL_AMNTYR sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-FIRSTPL_NUM sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-NEW_SALARY sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-CPAMT1 sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-CPAMTYR1 sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-CURRE1 sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-DFAMT1 sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-DFAMTYR1 sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-MIAMT1 sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-MIAMTYR1 sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-MAAMT1 sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-MAAMTYR1 sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-BSSAL1 sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-FIRSTPL_AMNT1 sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-FIRSTPL_AMNTYR1 sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-NEW_SALARY1 sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-CPNUM1 sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-STKUN1 sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-DFNUM1 sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-MINUM1 sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-MANUM1 sy-vline
WA_HRECM00BW_IS_COMP_PROC_13_STR-FIRSTPL_NUM1 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.