ABAP Select data from SAP table HRDEST_E2_S_ELSTAM_PROT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HRDEST_E2_S_ELSTAM_PROT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HRDEST_E2_S_ELSTAM_PROT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HRDEST_E2_S_ELSTAM_PROT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HRDEST_E2_S_ELSTAM_PROT TYPE STANDARD TABLE OF HRDEST_E2_S_ELSTAM_PROT,
      WA_HRDEST_E2_S_ELSTAM_PROT TYPE HRDEST_E2_S_ELSTAM_PROT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HRDEST_E2_S_ELSTAM_PROT> TYPE HRDEST_E2_S_ELSTAM_PROT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HRDEST_E2_S_ELSTAM_PROT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HRDEST_E2_S_ELSTAM_PROT
  INTO TABLE IT_HRDEST_E2_S_ELSTAM_PROT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HRDEST_E2_S_ELSTAM_PROT
*  INTO TABLE @DATA(IT_HRDEST_E2_S_ELSTAM_PROT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HRDEST_E2_S_ELSTAM_PROT INDEX 1 INTO DATA(WA_HRDEST_E2_S_ELSTAM_PROT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HRDEST_E2_S_ELSTAM_PROT ASSIGNING <HRDEST_E2_S_ELSTAM_PROT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HRDEST_E2_S_ELSTAM_PROT>-GUID = 1.
<HRDEST_E2_S_ELSTAM_PROT>-PERNR = 1.
<HRDEST_E2_S_ELSTAM_PROT>-IDNR = 1.
<HRDEST_E2_S_ELSTAM_PROT>-GUELTIGAB = 1.
<HRDEST_E2_S_ELSTAM_PROT>-STRKL = 1.
ENDLOOP.

LOOP AT IT_HRDEST_E2_S_ELSTAM_PROT INTO WA_HRDEST_E2_S_ELSTAM_PROT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HRDEST_E2_S_ELSTAM_PROT-KDFBT, sy-vline,
WA_HRDEST_E2_S_ELSTAM_PROT-FREIJ, sy-vline,
WA_HRDEST_E2_S_ELSTAM_PROT-FREIM, sy-vline,
WA_HRDEST_E2_S_ELSTAM_PROT-FREIW, sy-vline,
WA_HRDEST_E2_S_ELSTAM_PROT-FREIT, sy-vline,
WA_HRDEST_E2_S_ELSTAM_PROT-HINZJ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HRDEST_E2_S_ELSTAM_PROT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HRDEST_E2_S_ELSTAM_PROT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HRDEST_E2_S_ELSTAM_PROT INTO WA_HRDEST_E2_S_ELSTAM_PROT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HRDEST_E2_S_ELSTAM_PROT_STR,
GUID TYPE STRING,
PERNR TYPE STRING,
IDNR TYPE STRING,
GUELTIGAB TYPE STRING,
STRKL TYPE STRING,
KDFBT TYPE STRING,
FREIJ TYPE STRING,
FREIM TYPE STRING,
FREIW TYPE STRING,
FREIT TYPE STRING,
HINZJ TYPE STRING,
HINZM TYPE STRING,
HINZW TYPE STRING,
HINZT TYPE STRING,
KISTA TYPE STRING,
KISTE TYPE STRING,
FAKTOR TYPE STRING,
AGSTNR TYPE STRING,
FEHLER_NR TYPE STRING,
FEHLER_TXT TYPE STRING,
BESCHAEFTIGUNG TYPE STRING,
FEHLER_TYPE TYPE STRING,
FEHLER_DATUM TYPE STRING,
FEHLER_DATUM_ALT TYPE STRING,
SYSID TYPE STRING,
SYMDT TYPE STRING,END OF T_EKKO_STR. DATA: WA_HRDEST_E2_S_ELSTAM_PROT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-GUID sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-PERNR sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-IDNR sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-GUELTIGAB sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-STRKL sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-KDFBT sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-FREIJ sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-FREIM sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-FREIW sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-FREIT sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-HINZJ sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-HINZM sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-HINZW sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-HINZT sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-KISTA sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-KISTE sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-FAKTOR sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-AGSTNR sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-FEHLER_NR sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-FEHLER_TXT sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-BESCHAEFTIGUNG sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-FEHLER_TYPE sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-FEHLER_DATUM sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-FEHLER_DATUM_ALT sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-SYSID sy-vline
WA_HRDEST_E2_S_ELSTAM_PROT_STR-SYMDT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.