ABAP Select data from SAP table HR99S_S_DAQ_FICON into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HR99S_S_DAQ_FICON table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HR99S_S_DAQ_FICON. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HR99S_S_DAQ_FICON table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HR99S_S_DAQ_FICON TYPE STANDARD TABLE OF HR99S_S_DAQ_FICON,
      WA_HR99S_S_DAQ_FICON TYPE HR99S_S_DAQ_FICON,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HR99S_S_DAQ_FICON> TYPE HR99S_S_DAQ_FICON.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HR99S_S_DAQ_FICON.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HR99S_S_DAQ_FICON
  INTO TABLE IT_HR99S_S_DAQ_FICON.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HR99S_S_DAQ_FICON
*  INTO TABLE @DATA(IT_HR99S_S_DAQ_FICON2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HR99S_S_DAQ_FICON INDEX 1 INTO DATA(WA_HR99S_S_DAQ_FICON2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HR99S_S_DAQ_FICON ASSIGNING <HR99S_S_DAQ_FICON>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HR99S_S_DAQ_FICON>-ENDDA = 1.
<HR99S_S_DAQ_FICON>-BEGDA = 1.
<HR99S_S_DAQ_FICON>-FTYPE = 1.
<HR99S_S_DAQ_FICON>-TMSLT = 1.
<HR99S_S_DAQ_FICON>-CUMTM = 1.
ENDLOOP.

LOOP AT IT_HR99S_S_DAQ_FICON INTO WA_HR99S_S_DAQ_FICON.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HR99S_S_DAQ_FICON-CUMEE, sy-vline,
WA_HR99S_S_DAQ_FICON-CUMSP, sy-vline,
WA_HR99S_S_DAQ_FICON-CONDT, sy-vline,
WA_HR99S_S_DAQ_FICON-KEYFO, sy-vline,
WA_HR99S_S_DAQ_FICON-KEYSE, sy-vline,
WA_HR99S_S_DAQ_FICON-XMLTG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HR99S_S_DAQ_FICON you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HR99S_S_DAQ_FICON TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HR99S_S_DAQ_FICON INTO WA_HR99S_S_DAQ_FICON. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HR99S_S_DAQ_FICON_STR,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
FTYPE TYPE STRING,
TMSLT TYPE STRING,
CUMTM TYPE STRING,
CUMEE TYPE STRING,
CUMSP TYPE STRING,
CONDT TYPE STRING,
KEYFO TYPE STRING,
KEYSE TYPE STRING,
XMLTG TYPE STRING,
OBLIG TYPE STRING,
ORDSE TYPE STRING,
XMSCT TYPE STRING,
INFLD TYPE STRING,
INATR TYPE STRING,
RDIFF TYPE STRING,
XMORD TYPE STRING,
CPDEC TYPE STRING,
QUALF TYPE STRING,
XMLT2 TYPE STRING,END OF T_EKKO_STR. DATA: WA_HR99S_S_DAQ_FICON_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HR99S_S_DAQ_FICON_STR-ENDDA sy-vline
WA_HR99S_S_DAQ_FICON_STR-BEGDA sy-vline
WA_HR99S_S_DAQ_FICON_STR-FTYPE sy-vline
WA_HR99S_S_DAQ_FICON_STR-TMSLT sy-vline
WA_HR99S_S_DAQ_FICON_STR-CUMTM sy-vline
WA_HR99S_S_DAQ_FICON_STR-CUMEE sy-vline
WA_HR99S_S_DAQ_FICON_STR-CUMSP sy-vline
WA_HR99S_S_DAQ_FICON_STR-CONDT sy-vline
WA_HR99S_S_DAQ_FICON_STR-KEYFO sy-vline
WA_HR99S_S_DAQ_FICON_STR-KEYSE sy-vline
WA_HR99S_S_DAQ_FICON_STR-XMLTG sy-vline
WA_HR99S_S_DAQ_FICON_STR-OBLIG sy-vline
WA_HR99S_S_DAQ_FICON_STR-ORDSE sy-vline
WA_HR99S_S_DAQ_FICON_STR-XMSCT sy-vline
WA_HR99S_S_DAQ_FICON_STR-INFLD sy-vline
WA_HR99S_S_DAQ_FICON_STR-INATR sy-vline
WA_HR99S_S_DAQ_FICON_STR-RDIFF sy-vline
WA_HR99S_S_DAQ_FICON_STR-XMORD sy-vline
WA_HR99S_S_DAQ_FICON_STR-CPDEC sy-vline
WA_HR99S_S_DAQ_FICON_STR-QUALF sy-vline
WA_HR99S_S_DAQ_FICON_STR-XMLT2 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.