ABAP Select data from SAP table HR99S00_DELTA_S_T5F99FS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HR99S00_DELTA_S_T5F99FS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HR99S00_DELTA_S_T5F99FS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HR99S00_DELTA_S_T5F99FS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HR99S00_DELTA_S_T5F99FS TYPE STANDARD TABLE OF HR99S00_DELTA_S_T5F99FS,
      WA_HR99S00_DELTA_S_T5F99FS TYPE HR99S00_DELTA_S_T5F99FS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HR99S00_DELTA_S_T5F99FS> TYPE HR99S00_DELTA_S_T5F99FS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HR99S00_DELTA_S_T5F99FS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HR99S00_DELTA_S_T5F99FS
  INTO TABLE IT_HR99S00_DELTA_S_T5F99FS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HR99S00_DELTA_S_T5F99FS
*  INTO TABLE @DATA(IT_HR99S00_DELTA_S_T5F99FS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HR99S00_DELTA_S_T5F99FS INDEX 1 INTO DATA(WA_HR99S00_DELTA_S_T5F99FS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HR99S00_DELTA_S_T5F99FS ASSIGNING <HR99S00_DELTA_S_T5F99FS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HR99S00_DELTA_S_T5F99FS>-ICON = 1.
<HR99S00_DELTA_S_T5F99FS>-MANDT = 1.
<HR99S00_DELTA_S_T5F99FS>-MOLGA = 1.
<HR99S00_DELTA_S_T5F99FS>-APPL = 1.
<HR99S00_DELTA_S_T5F99FS>-SECTN = 1.
ENDLOOP.

LOOP AT IT_HR99S00_DELTA_S_T5F99FS INTO WA_HR99S00_DELTA_S_T5F99FS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HR99S00_DELTA_S_T5F99FS-ENDDA, sy-vline,
WA_HR99S00_DELTA_S_T5F99FS-BEGDA, sy-vline,
WA_HR99S00_DELTA_S_T5F99FS-STYPE, sy-vline,
WA_HR99S00_DELTA_S_T5F99FS-TMSLT, sy-vline,
WA_HR99S00_DELTA_S_T5F99FS-CUMTM, sy-vline,
WA_HR99S00_DELTA_S_T5F99FS-CUMEE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HR99S00_DELTA_S_T5F99FS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HR99S00_DELTA_S_T5F99FS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HR99S00_DELTA_S_T5F99FS INTO WA_HR99S00_DELTA_S_T5F99FS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HR99S00_DELTA_S_T5F99FS_STR,
ICON TYPE STRING,
MANDT TYPE STRING,
MOLGA TYPE STRING,
APPL TYPE STRING,
SECTN TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
STYPE TYPE STRING,
TMSLT TYPE STRING,
CUMTM TYPE STRING,
CUMEE TYPE STRING,
CONDT TYPE STRING,
STRCT TYPE STRING,
PRESE TYPE STRING,
HILEV TYPE STRING,
IDVAL TYPE STRING,
IDLEN TYPE STRING,
IDOFF TYPE STRING,
XMLTG TYPE STRING,
INSEC TYPE STRING,
INTYP TYPE STRING,
INATR TYPE STRING,
GRPSE TYPE STRING,
XMLT2 TYPE STRING,END OF T_EKKO_STR. DATA: WA_HR99S00_DELTA_S_T5F99FS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HR99S00_DELTA_S_T5F99FS_STR-ICON sy-vline
WA_HR99S00_DELTA_S_T5F99FS_STR-MANDT sy-vline
WA_HR99S00_DELTA_S_T5F99FS_STR-MOLGA sy-vline
WA_HR99S00_DELTA_S_T5F99FS_STR-APPL sy-vline
WA_HR99S00_DELTA_S_T5F99FS_STR-SECTN sy-vline
WA_HR99S00_DELTA_S_T5F99FS_STR-ENDDA sy-vline
WA_HR99S00_DELTA_S_T5F99FS_STR-BEGDA sy-vline
WA_HR99S00_DELTA_S_T5F99FS_STR-STYPE sy-vline
WA_HR99S00_DELTA_S_T5F99FS_STR-TMSLT sy-vline
WA_HR99S00_DELTA_S_T5F99FS_STR-CUMTM sy-vline
WA_HR99S00_DELTA_S_T5F99FS_STR-CUMEE sy-vline
WA_HR99S00_DELTA_S_T5F99FS_STR-CONDT sy-vline
WA_HR99S00_DELTA_S_T5F99FS_STR-STRCT sy-vline
WA_HR99S00_DELTA_S_T5F99FS_STR-PRESE sy-vline
WA_HR99S00_DELTA_S_T5F99FS_STR-HILEV sy-vline
WA_HR99S00_DELTA_S_T5F99FS_STR-IDVAL sy-vline
WA_HR99S00_DELTA_S_T5F99FS_STR-IDLEN sy-vline
WA_HR99S00_DELTA_S_T5F99FS_STR-IDOFF sy-vline
WA_HR99S00_DELTA_S_T5F99FS_STR-XMLTG sy-vline
WA_HR99S00_DELTA_S_T5F99FS_STR-INSEC sy-vline
WA_HR99S00_DELTA_S_T5F99FS_STR-INTYP sy-vline
WA_HR99S00_DELTA_S_T5F99FS_STR-INATR sy-vline
WA_HR99S00_DELTA_S_T5F99FS_STR-GRPSE sy-vline
WA_HR99S00_DELTA_S_T5F99FS_STR-XMLT2 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.