ABAP Select data from SAP table HNZLSUP0_ALV1 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HNZLSUP0_ALV1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HNZLSUP0_ALV1. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HNZLSUP0_ALV1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HNZLSUP0_ALV1 TYPE STANDARD TABLE OF HNZLSUP0_ALV1,
      WA_HNZLSUP0_ALV1 TYPE HNZLSUP0_ALV1,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HNZLSUP0_ALV1> TYPE HNZLSUP0_ALV1.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HNZLSUP0_ALV1.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HNZLSUP0_ALV1
  INTO TABLE IT_HNZLSUP0_ALV1.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HNZLSUP0_ALV1
*  INTO TABLE @DATA(IT_HNZLSUP0_ALV12).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HNZLSUP0_ALV1 INDEX 1 INTO DATA(WA_HNZLSUP0_ALV12).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HNZLSUP0_ALV1 ASSIGNING <HNZLSUP0_ALV1>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HNZLSUP0_ALV1>-BUKRS = 1.
<HNZLSUP0_ALV1>-ABKRS = 1.
<HNZLSUP0_ALV1>-PERNR = 1.
<HNZLSUP0_ALV1>-PABRP = 1.
<HNZLSUP0_ALV1>-PABRJ = 1.
ENDLOOP.

LOOP AT IT_HNZLSUP0_ALV1 INTO WA_HNZLSUP0_ALV1.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HNZLSUP0_ALV1-NAMEN, sy-vline,
WA_HNZLSUP0_ALV1-FCODE, sy-vline,
WA_HNZLSUP0_ALV1-FUND_NME, sy-vline,
WA_HNZLSUP0_ALV1-FTEXT, sy-vline,
WA_HNZLSUP0_ALV1-MEMNO, sy-vline,
WA_HNZLSUP0_ALV1-COMPCO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HNZLSUP0_ALV1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HNZLSUP0_ALV1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HNZLSUP0_ALV1 INTO WA_HNZLSUP0_ALV1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit GJAHR, internal->external for field PABRJ CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_HNZLSUP0_ALV1-PABRJ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HNZLSUP0_ALV1-PABRJ.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HNZLSUP0_ALV1_STR,
BUKRS TYPE STRING,
ABKRS TYPE STRING,
PERNR TYPE STRING,
PABRP TYPE STRING,
PABRJ TYPE STRING,
NAMEN TYPE STRING,
FCODE TYPE STRING,
FUND_NME TYPE STRING,
FTEXT TYPE STRING,
MEMNO TYPE STRING,
COMPCO TYPE STRING,
RERCO TYPE STRING,
SSCWT TYPE STRING,
NCCWT TYPE STRING,
EMPCO TYPE STRING,
REECO TYPE STRING,
MESSG TYPE STRING,
HFDAT TYPE STRING,END OF T_EKKO_STR. DATA: WA_HNZLSUP0_ALV1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HNZLSUP0_ALV1_STR-BUKRS sy-vline
WA_HNZLSUP0_ALV1_STR-ABKRS sy-vline
WA_HNZLSUP0_ALV1_STR-PERNR sy-vline
WA_HNZLSUP0_ALV1_STR-PABRP sy-vline
WA_HNZLSUP0_ALV1_STR-PABRJ sy-vline
WA_HNZLSUP0_ALV1_STR-NAMEN sy-vline
WA_HNZLSUP0_ALV1_STR-FCODE sy-vline
WA_HNZLSUP0_ALV1_STR-FUND_NME sy-vline
WA_HNZLSUP0_ALV1_STR-FTEXT sy-vline
WA_HNZLSUP0_ALV1_STR-MEMNO sy-vline
WA_HNZLSUP0_ALV1_STR-COMPCO sy-vline
WA_HNZLSUP0_ALV1_STR-RERCO sy-vline
WA_HNZLSUP0_ALV1_STR-SSCWT sy-vline
WA_HNZLSUP0_ALV1_STR-NCCWT sy-vline
WA_HNZLSUP0_ALV1_STR-EMPCO sy-vline
WA_HNZLSUP0_ALV1_STR-REECO sy-vline
WA_HNZLSUP0_ALV1_STR-MESSG sy-vline
WA_HNZLSUP0_ALV1_STR-HFDAT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.