ABAP Select data from SAP table HIKOLA_HIVG into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HIKOLA_HIVG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HIKOLA_HIVG. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HIKOLA_HIVG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HIKOLA_HIVG TYPE STANDARD TABLE OF HIKOLA_HIVG,
      WA_HIKOLA_HIVG TYPE HIKOLA_HIVG,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HIKOLA_HIVG> TYPE HIKOLA_HIVG.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HIKOLA_HIVG.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HIKOLA_HIVG
  INTO TABLE IT_HIKOLA_HIVG.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HIKOLA_HIVG
*  INTO TABLE @DATA(IT_HIKOLA_HIVG2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HIKOLA_HIVG INDEX 1 INTO DATA(WA_HIKOLA_HIVG2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HIKOLA_HIVG ASSIGNING <HIKOLA_HIVG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HIKOLA_HIVG>-MANDT = 1.
<HIKOLA_HIVG>-AUFNR = 1.
<HIKOLA_HIVG>-VORNR = 1.
<HIKOLA_HIVG>-UVORN = 1.
<HIKOLA_HIVG>-TPLNR = 1.
ENDLOOP.

LOOP AT IT_HIKOLA_HIVG INTO WA_HIKOLA_HIVG.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HIKOLA_HIVG-STRNO, sy-vline,
WA_HIKOLA_HIVG-AUART, sy-vline,
WA_HIKOLA_HIVG-AUTYP, sy-vline,
WA_HIKOLA_HIVG-KTEXT, sy-vline,
WA_HIKOLA_HIVG-LTEXT, sy-vline,
WA_HIKOLA_HIVG-LOEKZ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HIKOLA_HIVG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HIKOLA_HIVG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HIKOLA_HIVG INTO WA_HIKOLA_HIVG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-VORNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field UVORN CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-UVORN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-UVORN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLNR CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-TPLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-TPLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field STRNO CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-STRNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-STRNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MAUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-MAUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-MAUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LEAD_AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-LEAD_AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-LEAD_AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field PSPEL CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-PSPEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-PSPEL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-PLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-PLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-PLNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-EQUNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field BAUTL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-BAUTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-BAUTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-KUNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-KUNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GAUEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-GAUEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-GAUEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WARPL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-WARPL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-WARPL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WAPOS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-WAPOS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-WAPOS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LAUFN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-LAUFN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-LAUFN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field QMNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-QMNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-QMNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field SERIALNR CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-SERIALNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-SERIALNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field SERMAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-SERMAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-SERMAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field PROID CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-PROID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-PROID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ANLNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-ANLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-ANLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ANLUN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-ANLUN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-ANLUN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DAUFN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-DAUFN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-DAUFN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SAKTO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-SAKTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-SAKTO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-INFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-INFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field V_ISTRU CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-V_ISTRU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-V_ISTRU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field TXTSP CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-TXTSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-TXTSP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-MEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-MEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ARBEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-ARBEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-ARBEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field V_TPLNR CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-V_TPLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-V_TPLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field V_EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_HIKOLA_HIVG-V_EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HIKOLA_HIVG-V_EQUNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HIKOLA_HIVG_STR,
MANDT TYPE STRING,
AUFNR TYPE STRING,
VORNR TYPE STRING,
UVORN TYPE STRING,
TPLNR TYPE STRING,
STRNO TYPE STRING,
AUART TYPE STRING,
AUTYP TYPE STRING,
KTEXT TYPE STRING,
LTEXT TYPE STRING,
LOEKZ TYPE STRING,
MAUFNR TYPE STRING,
LEAD_AUFNR TYPE STRING,
PLVAR TYPE STRING,
OBJNR TYPE STRING,
VAPLZ TYPE STRING,
VAWRK TYPE STRING,
BUKRS TYPE STRING,
WERKS TYPE STRING,
GSBER TYPE STRING,
KOKRS TYPE STRING,
WAERS TYPE STRING,
GLTRP TYPE STRING,
GSTRP TYPE STRING,
GSTRI TYPE STRING,
GETRI TYPE STRING,
PSPEL TYPE STRING,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
PLNAL TYPE STRING,
ZAEHL TYPE STRING,
ERNAM TYPE STRING,
ERDAT TYPE STRING,
AENAM TYPE STRING,
AEDAT TYPE STRING,
ARTPR TYPE STRING,
PRIOK TYPE STRING,
EQUNR TYPE STRING,
BAUTL TYPE STRING,
ILOAN TYPE STRING,
ILOAI TYPE STRING,
ANLZU TYPE STRING,
IWERK TYPE STRING,
INGPR TYPE STRING,
PM_OBJTY TYPE STRING,
GEWRK TYPE STRING,
KUNUM TYPE STRING,
ANING TYPE STRING,
GAUZT TYPE STRING,
GAUEH TYPE STRING,
ANLBD TYPE STRING,
ANLVD TYPE STRING,
ANLBZ TYPE STRING,
ANLVZ TYPE STRING,
INSPK TYPE STRING,
DATAN TYPE STRING,
WARPL TYPE STRING,
ABNUM TYPE STRING,
WAPOS TYPE STRING,
LAUFN TYPE STRING,
OBKNR TYPE STRING,
REVNR TYPE STRING,
ADDAT TYPE STRING,
ADUHR TYPE STRING,
IPHAS TYPE STRING,
ILART TYPE STRING,
QMNUM TYPE STRING,
HISDA TYPE STRING,
AKKNZ TYPE STRING,
PLKNZ TYPE STRING,
USER4 TYPE STRING,
SERIALNR TYPE STRING,
SERMAT TYPE STRING,
DEVICEID TYPE STRING,
SCREENTY TYPE STRING,
UII TYPE STRING,
PLGRP TYPE STRING,
STORT TYPE STRING,
KOSTL TYPE STRING,
ABCKZ TYPE STRING,
EQFNR TYPE STRING,
SWERK TYPE STRING,
MSGRP TYPE STRING,
BEBER TYPE STRING,
CR_OBJTY TYPE STRING,
PPSID TYPE STRING,
PROID TYPE STRING,
ANLNR TYPE STRING,
ANLUN TYPE STRING,
DAUFN TYPE STRING,
OWNER TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
SPART TYPE STRING,
AUFPL TYPE STRING,
APLZL TYPE STRING,
STEUS TYPE STRING,
ARBID TYPE STRING,
V_WERKS TYPE STRING,
KTSCH TYPE STRING,
LTXA1 TYPE STRING,
LOANZ TYPE STRING,
LOART TYPE STRING,
QUALF TYPE STRING,
LOGRP TYPE STRING,
LIFNR TYPE STRING,
PREIS TYPE STRING,
PEINH TYPE STRING,
SAKTO TYPE STRING,
V_WAERS TYPE STRING,
INFNR TYPE STRING,
EKORG TYPE STRING,
EKGRP TYPE STRING,
MATKL TYPE STRING,
ANZZL TYPE STRING,
RUECK TYPE STRING,
RMZHL TYPE STRING,
V_OBJNR TYPE STRING,
V_ANLZU TYPE STRING,
V_ISTRU TYPE STRING,
PERNR TYPE STRING,
TXTSP TYPE STRING,
MEINH TYPE STRING,
ARBEI TYPE STRING,
ARBEH TYPE STRING,
ISMNW TYPE STRING,
ISDD TYPE STRING,
ISDZ TYPE STRING,
IEDD TYPE STRING,
IEDZ TYPE STRING,
AUFKT TYPE STRING,
V_TPLNR TYPE STRING,
V_EQUNR TYPE STRING,
CL_TYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_HIKOLA_HIVG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HIKOLA_HIVG_STR-MANDT sy-vline
WA_HIKOLA_HIVG_STR-AUFNR sy-vline
WA_HIKOLA_HIVG_STR-VORNR sy-vline
WA_HIKOLA_HIVG_STR-UVORN sy-vline
WA_HIKOLA_HIVG_STR-TPLNR sy-vline
WA_HIKOLA_HIVG_STR-STRNO sy-vline
WA_HIKOLA_HIVG_STR-AUART sy-vline
WA_HIKOLA_HIVG_STR-AUTYP sy-vline
WA_HIKOLA_HIVG_STR-KTEXT sy-vline
WA_HIKOLA_HIVG_STR-LTEXT sy-vline
WA_HIKOLA_HIVG_STR-LOEKZ sy-vline
WA_HIKOLA_HIVG_STR-MAUFNR sy-vline
WA_HIKOLA_HIVG_STR-LEAD_AUFNR sy-vline
WA_HIKOLA_HIVG_STR-PLVAR sy-vline
WA_HIKOLA_HIVG_STR-OBJNR sy-vline
WA_HIKOLA_HIVG_STR-VAPLZ sy-vline
WA_HIKOLA_HIVG_STR-VAWRK sy-vline
WA_HIKOLA_HIVG_STR-BUKRS sy-vline
WA_HIKOLA_HIVG_STR-WERKS sy-vline
WA_HIKOLA_HIVG_STR-GSBER sy-vline
WA_HIKOLA_HIVG_STR-KOKRS sy-vline
WA_HIKOLA_HIVG_STR-WAERS sy-vline
WA_HIKOLA_HIVG_STR-GLTRP sy-vline
WA_HIKOLA_HIVG_STR-GSTRP sy-vline
WA_HIKOLA_HIVG_STR-GSTRI sy-vline
WA_HIKOLA_HIVG_STR-GETRI sy-vline
WA_HIKOLA_HIVG_STR-PSPEL sy-vline
WA_HIKOLA_HIVG_STR-PLNTY sy-vline
WA_HIKOLA_HIVG_STR-PLNNR sy-vline
WA_HIKOLA_HIVG_STR-PLNAL sy-vline
WA_HIKOLA_HIVG_STR-ZAEHL sy-vline
WA_HIKOLA_HIVG_STR-ERNAM sy-vline
WA_HIKOLA_HIVG_STR-ERDAT sy-vline
WA_HIKOLA_HIVG_STR-AENAM sy-vline
WA_HIKOLA_HIVG_STR-AEDAT sy-vline
WA_HIKOLA_HIVG_STR-ARTPR sy-vline
WA_HIKOLA_HIVG_STR-PRIOK sy-vline
WA_HIKOLA_HIVG_STR-EQUNR sy-vline
WA_HIKOLA_HIVG_STR-BAUTL sy-vline
WA_HIKOLA_HIVG_STR-ILOAN sy-vline
WA_HIKOLA_HIVG_STR-ILOAI sy-vline
WA_HIKOLA_HIVG_STR-ANLZU sy-vline
WA_HIKOLA_HIVG_STR-IWERK sy-vline
WA_HIKOLA_HIVG_STR-INGPR sy-vline
WA_HIKOLA_HIVG_STR-PM_OBJTY sy-vline
WA_HIKOLA_HIVG_STR-GEWRK sy-vline
WA_HIKOLA_HIVG_STR-KUNUM sy-vline
WA_HIKOLA_HIVG_STR-ANING sy-vline
WA_HIKOLA_HIVG_STR-GAUZT sy-vline
WA_HIKOLA_HIVG_STR-GAUEH sy-vline
WA_HIKOLA_HIVG_STR-ANLBD sy-vline
WA_HIKOLA_HIVG_STR-ANLVD sy-vline
WA_HIKOLA_HIVG_STR-ANLBZ sy-vline
WA_HIKOLA_HIVG_STR-ANLVZ sy-vline
WA_HIKOLA_HIVG_STR-INSPK sy-vline
WA_HIKOLA_HIVG_STR-DATAN sy-vline
WA_HIKOLA_HIVG_STR-WARPL sy-vline
WA_HIKOLA_HIVG_STR-ABNUM sy-vline
WA_HIKOLA_HIVG_STR-WAPOS sy-vline
WA_HIKOLA_HIVG_STR-LAUFN sy-vline
WA_HIKOLA_HIVG_STR-OBKNR sy-vline
WA_HIKOLA_HIVG_STR-REVNR sy-vline
WA_HIKOLA_HIVG_STR-ADDAT sy-vline
WA_HIKOLA_HIVG_STR-ADUHR sy-vline
WA_HIKOLA_HIVG_STR-IPHAS sy-vline
WA_HIKOLA_HIVG_STR-ILART sy-vline
WA_HIKOLA_HIVG_STR-QMNUM sy-vline
WA_HIKOLA_HIVG_STR-HISDA sy-vline
WA_HIKOLA_HIVG_STR-AKKNZ sy-vline
WA_HIKOLA_HIVG_STR-PLKNZ sy-vline
WA_HIKOLA_HIVG_STR-USER4 sy-vline
WA_HIKOLA_HIVG_STR-SERIALNR sy-vline
WA_HIKOLA_HIVG_STR-SERMAT sy-vline
WA_HIKOLA_HIVG_STR-DEVICEID sy-vline
WA_HIKOLA_HIVG_STR-SCREENTY sy-vline
WA_HIKOLA_HIVG_STR-UII sy-vline
WA_HIKOLA_HIVG_STR-PLGRP sy-vline
WA_HIKOLA_HIVG_STR-STORT sy-vline
WA_HIKOLA_HIVG_STR-KOSTL sy-vline
WA_HIKOLA_HIVG_STR-ABCKZ sy-vline
WA_HIKOLA_HIVG_STR-EQFNR sy-vline
WA_HIKOLA_HIVG_STR-SWERK sy-vline
WA_HIKOLA_HIVG_STR-MSGRP sy-vline
WA_HIKOLA_HIVG_STR-BEBER sy-vline
WA_HIKOLA_HIVG_STR-CR_OBJTY sy-vline
WA_HIKOLA_HIVG_STR-PPSID sy-vline
WA_HIKOLA_HIVG_STR-PROID sy-vline
WA_HIKOLA_HIVG_STR-ANLNR sy-vline
WA_HIKOLA_HIVG_STR-ANLUN sy-vline
WA_HIKOLA_HIVG_STR-DAUFN sy-vline
WA_HIKOLA_HIVG_STR-OWNER sy-vline
WA_HIKOLA_HIVG_STR-VKORG sy-vline
WA_HIKOLA_HIVG_STR-VTWEG sy-vline
WA_HIKOLA_HIVG_STR-SPART sy-vline
WA_HIKOLA_HIVG_STR-AUFPL sy-vline
WA_HIKOLA_HIVG_STR-APLZL sy-vline
WA_HIKOLA_HIVG_STR-STEUS sy-vline
WA_HIKOLA_HIVG_STR-ARBID sy-vline
WA_HIKOLA_HIVG_STR-V_WERKS sy-vline
WA_HIKOLA_HIVG_STR-KTSCH sy-vline
WA_HIKOLA_HIVG_STR-LTXA1 sy-vline
WA_HIKOLA_HIVG_STR-LOANZ sy-vline
WA_HIKOLA_HIVG_STR-LOART sy-vline
WA_HIKOLA_HIVG_STR-QUALF sy-vline
WA_HIKOLA_HIVG_STR-LOGRP sy-vline
WA_HIKOLA_HIVG_STR-LIFNR sy-vline
WA_HIKOLA_HIVG_STR-PREIS sy-vline
WA_HIKOLA_HIVG_STR-PEINH sy-vline
WA_HIKOLA_HIVG_STR-SAKTO sy-vline
WA_HIKOLA_HIVG_STR-V_WAERS sy-vline
WA_HIKOLA_HIVG_STR-INFNR sy-vline
WA_HIKOLA_HIVG_STR-EKORG sy-vline
WA_HIKOLA_HIVG_STR-EKGRP sy-vline
WA_HIKOLA_HIVG_STR-MATKL sy-vline
WA_HIKOLA_HIVG_STR-ANZZL sy-vline
WA_HIKOLA_HIVG_STR-RUECK sy-vline
WA_HIKOLA_HIVG_STR-RMZHL sy-vline
WA_HIKOLA_HIVG_STR-V_OBJNR sy-vline
WA_HIKOLA_HIVG_STR-V_ANLZU sy-vline
WA_HIKOLA_HIVG_STR-V_ISTRU sy-vline
WA_HIKOLA_HIVG_STR-PERNR sy-vline
WA_HIKOLA_HIVG_STR-TXTSP sy-vline
WA_HIKOLA_HIVG_STR-MEINH sy-vline
WA_HIKOLA_HIVG_STR-ARBEI sy-vline
WA_HIKOLA_HIVG_STR-ARBEH sy-vline
WA_HIKOLA_HIVG_STR-ISMNW sy-vline
WA_HIKOLA_HIVG_STR-ISDD sy-vline
WA_HIKOLA_HIVG_STR-ISDZ sy-vline
WA_HIKOLA_HIVG_STR-IEDD sy-vline
WA_HIKOLA_HIVG_STR-IEDZ sy-vline
WA_HIKOLA_HIVG_STR-AUFKT sy-vline
WA_HIKOLA_HIVG_STR-V_TPLNR sy-vline
WA_HIKOLA_HIVG_STR-V_EQUNR sy-vline
WA_HIKOLA_HIVG_STR-CL_TYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.