ABAP Select data from SAP table HCMT_BSP_PA_IN_R0580 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HCMT_BSP_PA_IN_R0580 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HCMT_BSP_PA_IN_R0580. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HCMT_BSP_PA_IN_R0580 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HCMT_BSP_PA_IN_R0580 TYPE STANDARD TABLE OF HCMT_BSP_PA_IN_R0580,
      WA_HCMT_BSP_PA_IN_R0580 TYPE HCMT_BSP_PA_IN_R0580,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HCMT_BSP_PA_IN_R0580> TYPE HCMT_BSP_PA_IN_R0580.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HCMT_BSP_PA_IN_R0580.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HCMT_BSP_PA_IN_R0580
  INTO TABLE IT_HCMT_BSP_PA_IN_R0580.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HCMT_BSP_PA_IN_R0580
*  INTO TABLE @DATA(IT_HCMT_BSP_PA_IN_R05802).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HCMT_BSP_PA_IN_R0580 INDEX 1 INTO DATA(WA_HCMT_BSP_PA_IN_R05802).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HCMT_BSP_PA_IN_R0580 ASSIGNING <HCMT_BSP_PA_IN_R0580>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HCMT_BSP_PA_IN_R0580>-OBJECT_KEY = 1.
<HCMT_BSP_PA_IN_R0580>-PERNR = 1.
<HCMT_BSP_PA_IN_R0580>-AEDTM = 1.
<HCMT_BSP_PA_IN_R0580>-UNAME = 1.
<HCMT_BSP_PA_IN_R0580>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_HCMT_BSP_PA_IN_R0580 INTO WA_HCMT_BSP_PA_IN_R0580.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HCMT_BSP_PA_IN_R0580-SPRTX, sy-vline,
WA_HCMT_BSP_PA_IN_R0580-ITBLD, sy-vline,
WA_HCMT_BSP_PA_IN_R0580-ITXEX, sy-vline,
WA_HCMT_BSP_PA_IN_R0580-BEGDA, sy-vline,
WA_HCMT_BSP_PA_IN_R0580-ENDDA, sy-vline,
WA_HCMT_BSP_PA_IN_R0580-GRSAL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HCMT_BSP_PA_IN_R0580 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HCMT_BSP_PA_IN_R0580 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HCMT_BSP_PA_IN_R0580 INTO WA_HCMT_BSP_PA_IN_R0580. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HCMT_BSP_PA_IN_R0580_STR,
OBJECT_KEY TYPE STRING,
PERNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
SPRPS TYPE STRING,
SPRTX TYPE STRING,
ITBLD TYPE STRING,
ITXEX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
GRSAL TYPE STRING,
WAE01 TYPE STRING,
VPRQS TYPE STRING,
WAE02 TYPE STRING,
PRSAL TYPE STRING,
WAE03 TYPE STRING,
EXS10 TYPE STRING,
WAE04 TYPE STRING,
PRTAX TYPE STRING,
WAE05 TYPE STRING,
PRFND TYPE STRING,
WAE06 TYPE STRING,
TXDED TYPE STRING,
WAE07 TYPE STRING,
MEDEX TYPE STRING,
WAE08 TYPE STRING,
LEAEX TYPE STRING,
WAE09 TYPE STRING,
GRYEX TYPE STRING,
WAE10 TYPE STRING,
VRSEX TYPE STRING,
WAE11 TYPE STRING,
LTAEX TYPE STRING,
LTACF TYPE STRING,
SCDED TYPE STRING,
WAE12 TYPE STRING,
ECDED TYPE STRING,
WAE13 TYPE STRING,
NPERC TYPE STRING,
NPEEC TYPE STRING,
NPERB TYPE STRING,
NPEEB TYPE STRING,
WAE14 TYPE STRING,
WAE15 TYPE STRING,
WAE16 TYPE STRING,
WAE17 TYPE STRING,
GROSL TYPE STRING,
VOPRS TYPE STRING,
PLSAL TYPE STRING,
SRDED TYPE STRING,
ITDED TYPE STRING,
RETEX TYPE STRING,
WAE18 TYPE STRING,
ERPFC TYPE STRING,
ERSAN TYPE STRING,
WAE19 TYPE STRING,
WAE20 TYPE STRING,END OF T_EKKO_STR. DATA: WA_HCMT_BSP_PA_IN_R0580_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-OBJECT_KEY sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-PERNR sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-AEDTM sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-UNAME sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-SPRPS sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-SPRTX sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-ITBLD sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-ITXEX sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-BEGDA sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-ENDDA sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-GRSAL sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-WAE01 sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-VPRQS sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-WAE02 sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-PRSAL sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-WAE03 sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-EXS10 sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-WAE04 sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-PRTAX sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-WAE05 sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-PRFND sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-WAE06 sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-TXDED sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-WAE07 sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-MEDEX sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-WAE08 sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-LEAEX sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-WAE09 sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-GRYEX sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-WAE10 sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-VRSEX sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-WAE11 sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-LTAEX sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-LTACF sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-SCDED sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-WAE12 sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-ECDED sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-WAE13 sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-NPERC sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-NPEEC sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-NPERB sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-NPEEB sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-WAE14 sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-WAE15 sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-WAE16 sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-WAE17 sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-GROSL sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-VOPRS sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-PLSAL sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-SRDED sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-ITDED sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-RETEX sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-WAE18 sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-ERPFC sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-ERSAN sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-WAE19 sy-vline
WA_HCMT_BSP_PA_IN_R0580_STR-WAE20 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.