ABAP Select data from SAP table HCMT_BSP_PA_HU_R0644 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HCMT_BSP_PA_HU_R0644 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HCMT_BSP_PA_HU_R0644. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HCMT_BSP_PA_HU_R0644 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HCMT_BSP_PA_HU_R0644 TYPE STANDARD TABLE OF HCMT_BSP_PA_HU_R0644,
      WA_HCMT_BSP_PA_HU_R0644 TYPE HCMT_BSP_PA_HU_R0644,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HCMT_BSP_PA_HU_R0644> TYPE HCMT_BSP_PA_HU_R0644.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HCMT_BSP_PA_HU_R0644.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HCMT_BSP_PA_HU_R0644
  INTO TABLE IT_HCMT_BSP_PA_HU_R0644.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HCMT_BSP_PA_HU_R0644
*  INTO TABLE @DATA(IT_HCMT_BSP_PA_HU_R06442).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HCMT_BSP_PA_HU_R0644 INDEX 1 INTO DATA(WA_HCMT_BSP_PA_HU_R06442).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HCMT_BSP_PA_HU_R0644 ASSIGNING <HCMT_BSP_PA_HU_R0644>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HCMT_BSP_PA_HU_R0644>-OBJECT_KEY = 1.
<HCMT_BSP_PA_HU_R0644>-PERNR = 1.
<HCMT_BSP_PA_HU_R0644>-AEDTM = 1.
<HCMT_BSP_PA_HU_R0644>-UNAME = 1.
<HCMT_BSP_PA_HU_R0644>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_HCMT_BSP_PA_HU_R0644 INTO WA_HCMT_BSP_PA_HU_R0644.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HCMT_BSP_PA_HU_R0644-SPRTX, sy-vline,
WA_HCMT_BSP_PA_HU_R0644-ITBLD, sy-vline,
WA_HCMT_BSP_PA_HU_R0644-ITXEX, sy-vline,
WA_HCMT_BSP_PA_HU_R0644-BEGDA, sy-vline,
WA_HCMT_BSP_PA_HU_R0644-ENDDA, sy-vline,
WA_HCMT_BSP_PA_HU_R0644-VHELD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HCMT_BSP_PA_HU_R0644 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HCMT_BSP_PA_HU_R0644 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HCMT_BSP_PA_HU_R0644 INTO WA_HCMT_BSP_PA_HU_R0644. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HCMT_BSP_PA_HU_R0644_STR,
OBJECT_KEY TYPE STRING,
PERNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
SPRPS TYPE STRING,
SPRTX TYPE STRING,
ITBLD TYPE STRING,
ITXEX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
VHELD TYPE STRING,
VHELK TYPE STRING,
VHELM TYPE STRING,
HATHT TYPE STRING,
HATHI TYPE STRING,
HATHK TYPE STRING,
HATHM TYPE STRING,
HKSZN TYPE STRING,
HKSZK TYPE STRING,
HKSZM TYPE STRING,
VKATD TYPE STRING,
VKATK TYPE STRING,
VKATM TYPE STRING,
VKSZN TYPE STRING,
VKSZK TYPE STRING,
VKSZM TYPE STRING,
MSATD TYPE STRING,
MSATK TYPE STRING,
MSATM TYPE STRING,
MSKIN TYPE STRING,
MSKIK TYPE STRING,
MSKIM TYPE STRING,
KJVMD TYPE STRING,
KJVMK TYPE STRING,
KJVMM TYPE STRING,
KJVEV TYPE STRING,
KJVHO TYPE STRING,
KJVNA TYPE STRING,
VEGKD TYPE STRING,
RDAHD TYPE STRING,
FELMK TYPE STRING,
FELMM TYPE STRING,END OF T_EKKO_STR. DATA: WA_HCMT_BSP_PA_HU_R0644_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-OBJECT_KEY sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-PERNR sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-AEDTM sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-UNAME sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-SPRPS sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-SPRTX sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-ITBLD sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-ITXEX sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-BEGDA sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-ENDDA sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-VHELD sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-VHELK sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-VHELM sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-HATHT sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-HATHI sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-HATHK sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-HATHM sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-HKSZN sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-HKSZK sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-HKSZM sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-VKATD sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-VKATK sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-VKATM sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-VKSZN sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-VKSZK sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-VKSZM sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-MSATD sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-MSATK sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-MSATM sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-MSKIN sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-MSKIK sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-MSKIM sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-KJVMD sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-KJVMK sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-KJVMM sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-KJVEV sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-KJVHO sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-KJVNA sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-VEGKD sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-RDAHD sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-FELMK sy-vline
WA_HCMT_BSP_PA_HU_R0644_STR-FELMM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.