ABAP Select data from SAP table HCMT_BSP_PA_HR_R0562 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HCMT_BSP_PA_HR_R0562 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HCMT_BSP_PA_HR_R0562. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HCMT_BSP_PA_HR_R0562 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HCMT_BSP_PA_HR_R0562 TYPE STANDARD TABLE OF HCMT_BSP_PA_HR_R0562,
      WA_HCMT_BSP_PA_HR_R0562 TYPE HCMT_BSP_PA_HR_R0562,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HCMT_BSP_PA_HR_R0562> TYPE HCMT_BSP_PA_HR_R0562.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HCMT_BSP_PA_HR_R0562.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HCMT_BSP_PA_HR_R0562
  INTO TABLE IT_HCMT_BSP_PA_HR_R0562.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HCMT_BSP_PA_HR_R0562
*  INTO TABLE @DATA(IT_HCMT_BSP_PA_HR_R05622).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HCMT_BSP_PA_HR_R0562 INDEX 1 INTO DATA(WA_HCMT_BSP_PA_HR_R05622).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HCMT_BSP_PA_HR_R0562 ASSIGNING <HCMT_BSP_PA_HR_R0562>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HCMT_BSP_PA_HR_R0562>-OBJECT_KEY = 1.
<HCMT_BSP_PA_HR_R0562>-PERNR = 1.
<HCMT_BSP_PA_HR_R0562>-AEDTM = 1.
<HCMT_BSP_PA_HR_R0562>-UNAME = 1.
<HCMT_BSP_PA_HR_R0562>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_HCMT_BSP_PA_HR_R0562 INTO WA_HCMT_BSP_PA_HR_R0562.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HCMT_BSP_PA_HR_R0562-SPRTX, sy-vline,
WA_HCMT_BSP_PA_HR_R0562-ITBLD, sy-vline,
WA_HCMT_BSP_PA_HR_R0562-ITXEX, sy-vline,
WA_HCMT_BSP_PA_HR_R0562-BEGDA, sy-vline,
WA_HCMT_BSP_PA_HR_R0562-ENDDA, sy-vline,
WA_HCMT_BSP_PA_HR_R0562-MUNCO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HCMT_BSP_PA_HR_R0562 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HCMT_BSP_PA_HR_R0562 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HCMT_BSP_PA_HR_R0562 INTO WA_HCMT_BSP_PA_HR_R0562. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HCMT_BSP_PA_HR_R0562_STR,
OBJECT_KEY TYPE STRING,
PERNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
SPRPS TYPE STRING,
SPRTX TYPE STRING,
ITBLD TYPE STRING,
ITXEX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
MUNCO TYPE STRING,
MUNTX TYPE STRING,
BEZEI TYPE STRING,
OIB TYPE STRING,
JMBG TYPE STRING,
ICNUM TYPE STRING,
ICDAT TYPE STRING,
ICISS TYPE STRING,
HICOD TYPE STRING,
HICODTXT TYPE STRING,
HICO2 TYPE STRING,
HICO2TXT TYPE STRING,
HINUM TYPE STRING,
HIDAT TYPE STRING,
HIISS TYPE STRING,
SSNUM TYPE STRING,
SSDAT TYPE STRING,
SSISS TYPE STRING,
RBOPD TYPE STRING,
WBNUM TYPE STRING,
WBREG TYPE STRING,
WBDAT TYPE STRING,
WBISS TYPE STRING,END OF T_EKKO_STR. DATA: WA_HCMT_BSP_PA_HR_R0562_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-OBJECT_KEY sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-PERNR sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-AEDTM sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-UNAME sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-SPRPS sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-SPRTX sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-ITBLD sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-ITXEX sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-BEGDA sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-ENDDA sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-MUNCO sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-MUNTX sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-BEZEI sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-OIB sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-JMBG sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-ICNUM sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-ICDAT sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-ICISS sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-HICOD sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-HICODTXT sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-HICO2 sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-HICO2TXT sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-HINUM sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-HIDAT sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-HIISS sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-SSNUM sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-SSDAT sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-SSISS sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-RBOPD sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-WBNUM sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-WBREG sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-WBDAT sy-vline
WA_HCMT_BSP_PA_HR_R0562_STR-WBISS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.