ABAP Select data from SAP table HCMT_BSP_PA_HK_R0002 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HCMT_BSP_PA_HK_R0002 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HCMT_BSP_PA_HK_R0002. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HCMT_BSP_PA_HK_R0002 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HCMT_BSP_PA_HK_R0002 TYPE STANDARD TABLE OF HCMT_BSP_PA_HK_R0002,
      WA_HCMT_BSP_PA_HK_R0002 TYPE HCMT_BSP_PA_HK_R0002,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HCMT_BSP_PA_HK_R0002> TYPE HCMT_BSP_PA_HK_R0002.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HCMT_BSP_PA_HK_R0002.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HCMT_BSP_PA_HK_R0002
  INTO TABLE IT_HCMT_BSP_PA_HK_R0002.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HCMT_BSP_PA_HK_R0002
*  INTO TABLE @DATA(IT_HCMT_BSP_PA_HK_R00022).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HCMT_BSP_PA_HK_R0002 INDEX 1 INTO DATA(WA_HCMT_BSP_PA_HK_R00022).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HCMT_BSP_PA_HK_R0002 ASSIGNING <HCMT_BSP_PA_HK_R0002>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HCMT_BSP_PA_HK_R0002>-OBJECT_KEY = 1.
<HCMT_BSP_PA_HK_R0002>-PERNR = 1.
<HCMT_BSP_PA_HK_R0002>-AEDTM = 1.
<HCMT_BSP_PA_HK_R0002>-UNAME = 1.
<HCMT_BSP_PA_HK_R0002>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_HCMT_BSP_PA_HK_R0002 INTO WA_HCMT_BSP_PA_HK_R0002.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HCMT_BSP_PA_HK_R0002-SPRTX, sy-vline,
WA_HCMT_BSP_PA_HK_R0002-ITBLD, sy-vline,
WA_HCMT_BSP_PA_HK_R0002-ITXEX, sy-vline,
WA_HCMT_BSP_PA_HK_R0002-BEGDA, sy-vline,
WA_HCMT_BSP_PA_HK_R0002-ENDDA, sy-vline,
WA_HCMT_BSP_PA_HK_R0002-ANRED, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HCMT_BSP_PA_HK_R0002 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HCMT_BSP_PA_HK_R0002 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HCMT_BSP_PA_HK_R0002 INTO WA_HCMT_BSP_PA_HK_R0002. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field SPRSL CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_HCMT_BSP_PA_HK_R0002-SPRSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HCMT_BSP_PA_HK_R0002-SPRSL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PDATE, internal->external for field GBDAT CALL FUNCTION 'CONVERSION_EXIT_PDATE_OUTPUT' EXPORTING input = WA_HCMT_BSP_PA_HK_R0002-GBDAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HCMT_BSP_PA_HK_R0002-GBDAT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HCMT_BSP_PA_HK_R0002_STR,
OBJECT_KEY TYPE STRING,
PERNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
SPRPS TYPE STRING,
SPRTX TYPE STRING,
ITBLD TYPE STRING,
ITXEX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
ANRED TYPE STRING,
INITS TYPE STRING,
NACHN TYPE STRING,
NAME2 TYPE STRING,
VORNA TYPE STRING,
RUFNM TYPE STRING,
TITL2 TYPE STRING,
VORSW TYPE STRING,
KNZNM TYPE STRING,
ENAME TYPE STRING,
SPRSL TYPE STRING,
GBDAT TYPE STRING,
GBORT TYPE STRING,
GBLND TYPE STRING,
GBDEP TYPE STRING,
NATIO TYPE STRING,
NATI2 TYPE STRING,
NATI3 TYPE STRING,
ANZKD TYPE STRING,
FAMST TYPE STRING,
FAMDT TYPE STRING,
MACNO TYPE STRING,
GESCH TYPE STRING,
ANREX TYPE STRING,
LANDX TYPE STRING,
NATIX TYPE STRING,
NA2TX TYPE STRING,
NA3TX TYPE STRING,
GESTX TYPE STRING,
FATXT TYPE STRING,
SPTXT TYPE STRING,
BEZEI TYPE STRING,END OF T_EKKO_STR. DATA: WA_HCMT_BSP_PA_HK_R0002_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-OBJECT_KEY sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-PERNR sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-AEDTM sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-UNAME sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-SPRPS sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-SPRTX sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-ITBLD sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-ITXEX sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-BEGDA sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-ENDDA sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-ANRED sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-INITS sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-NACHN sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-NAME2 sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-VORNA sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-RUFNM sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-TITL2 sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-VORSW sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-KNZNM sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-ENAME sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-SPRSL sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-GBDAT sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-GBORT sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-GBLND sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-GBDEP sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-NATIO sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-NATI2 sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-NATI3 sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-ANZKD sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-FAMST sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-FAMDT sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-MACNO sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-GESCH sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-ANREX sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-LANDX sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-NATIX sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-NA2TX sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-NA3TX sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-GESTX sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-FATXT sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-SPTXT sy-vline
WA_HCMT_BSP_PA_HK_R0002_STR-BEZEI sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.