ABAP Select data from SAP table HCMT_BSP_PA_GB_R3216 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HCMT_BSP_PA_GB_R3216 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HCMT_BSP_PA_GB_R3216. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HCMT_BSP_PA_GB_R3216 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HCMT_BSP_PA_GB_R3216 TYPE STANDARD TABLE OF HCMT_BSP_PA_GB_R3216,
      WA_HCMT_BSP_PA_GB_R3216 TYPE HCMT_BSP_PA_GB_R3216,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HCMT_BSP_PA_GB_R3216> TYPE HCMT_BSP_PA_GB_R3216.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HCMT_BSP_PA_GB_R3216.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HCMT_BSP_PA_GB_R3216
  INTO TABLE IT_HCMT_BSP_PA_GB_R3216.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HCMT_BSP_PA_GB_R3216
*  INTO TABLE @DATA(IT_HCMT_BSP_PA_GB_R32162).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HCMT_BSP_PA_GB_R3216 INDEX 1 INTO DATA(WA_HCMT_BSP_PA_GB_R32162).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HCMT_BSP_PA_GB_R3216 ASSIGNING <HCMT_BSP_PA_GB_R3216>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HCMT_BSP_PA_GB_R3216>-OBJECT_KEY = 1.
<HCMT_BSP_PA_GB_R3216>-PERNR = 1.
<HCMT_BSP_PA_GB_R3216>-AEDTM = 1.
<HCMT_BSP_PA_GB_R3216>-UNAME = 1.
<HCMT_BSP_PA_GB_R3216>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_HCMT_BSP_PA_GB_R3216 INTO WA_HCMT_BSP_PA_GB_R3216.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HCMT_BSP_PA_GB_R3216-SPRTX, sy-vline,
WA_HCMT_BSP_PA_GB_R3216-ITBLD, sy-vline,
WA_HCMT_BSP_PA_GB_R3216-ITXEX, sy-vline,
WA_HCMT_BSP_PA_GB_R3216-BEGDA, sy-vline,
WA_HCMT_BSP_PA_GB_R3216-ENDDA, sy-vline,
WA_HCMT_BSP_PA_GB_R3216-CONTY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HCMT_BSP_PA_GB_R3216 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HCMT_BSP_PA_GB_R3216 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HCMT_BSP_PA_GB_R3216 INTO WA_HCMT_BSP_PA_GB_R3216. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HCMT_BSP_PA_GB_R3216_STR,
OBJECT_KEY TYPE STRING,
PERNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
SPRPS TYPE STRING,
SPRTX TYPE STRING,
ITBLD TYPE STRING,
ITXEX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
CONTY TYPE STRING,
CONTYT TYPE STRING,
POST TYPE STRING,
POSTT TYPE STRING,
DOAIS TYPE STRING,
DESTN TYPE STRING,
DESTNT TYPE STRING,
ORIGN TYPE STRING,
ORIGNT TYPE STRING,
ROLE1 TYPE STRING,
AHRS1 TYPE STRING,
FHRS1 TYPE STRING,
WKPA1 TYPE STRING,
ROLE2 TYPE STRING,
AHRS2 TYPE STRING,
FHRS2 TYPE STRING,
WKPA2 TYPE STRING,
ROLE3 TYPE STRING,
AHRS3 TYPE STRING,
FHRS3 TYPE STRING,
WKPA3 TYPE STRING,
ROLE4 TYPE STRING,
AHRS4 TYPE STRING,
FHRS4 TYPE STRING,
WKPA4 TYPE STRING,
ROLE5 TYPE STRING,
AHRS5 TYPE STRING,
FHRS5 TYPE STRING,
WKPA5 TYPE STRING,
CTBEG TYPE STRING,
CTEND TYPE STRING,
ETYPE TYPE STRING,
PRDAT TYPE STRING,
PAYFR TYPE STRING,
RSN4ALV TYPE STRING,END OF T_EKKO_STR. DATA: WA_HCMT_BSP_PA_GB_R3216_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-OBJECT_KEY sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-PERNR sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-AEDTM sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-UNAME sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-SPRPS sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-SPRTX sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-ITBLD sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-ITXEX sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-BEGDA sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-ENDDA sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-CONTY sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-CONTYT sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-POST sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-POSTT sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-DOAIS sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-DESTN sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-DESTNT sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-ORIGN sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-ORIGNT sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-ROLE1 sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-AHRS1 sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-FHRS1 sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-WKPA1 sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-ROLE2 sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-AHRS2 sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-FHRS2 sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-WKPA2 sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-ROLE3 sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-AHRS3 sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-FHRS3 sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-WKPA3 sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-ROLE4 sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-AHRS4 sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-FHRS4 sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-WKPA4 sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-ROLE5 sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-AHRS5 sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-FHRS5 sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-WKPA5 sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-CTBEG sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-CTEND sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-ETYPE sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-PRDAT sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-PAYFR sy-vline
WA_HCMT_BSP_PA_GB_R3216_STR-RSN4ALV sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.