ABAP Select data from SAP table HCMT_BSP_PA_GB_R0614 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HCMT_BSP_PA_GB_R0614 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HCMT_BSP_PA_GB_R0614. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HCMT_BSP_PA_GB_R0614 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HCMT_BSP_PA_GB_R0614 TYPE STANDARD TABLE OF HCMT_BSP_PA_GB_R0614,
      WA_HCMT_BSP_PA_GB_R0614 TYPE HCMT_BSP_PA_GB_R0614,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HCMT_BSP_PA_GB_R0614> TYPE HCMT_BSP_PA_GB_R0614.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HCMT_BSP_PA_GB_R0614.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HCMT_BSP_PA_GB_R0614
  INTO TABLE IT_HCMT_BSP_PA_GB_R0614.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HCMT_BSP_PA_GB_R0614
*  INTO TABLE @DATA(IT_HCMT_BSP_PA_GB_R06142).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HCMT_BSP_PA_GB_R0614 INDEX 1 INTO DATA(WA_HCMT_BSP_PA_GB_R06142).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HCMT_BSP_PA_GB_R0614 ASSIGNING <HCMT_BSP_PA_GB_R0614>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HCMT_BSP_PA_GB_R0614>-OBJECT_KEY = 1.
<HCMT_BSP_PA_GB_R0614>-PERNR = 1.
<HCMT_BSP_PA_GB_R0614>-AEDTM = 1.
<HCMT_BSP_PA_GB_R0614>-UNAME = 1.
<HCMT_BSP_PA_GB_R0614>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_HCMT_BSP_PA_GB_R0614 INTO WA_HCMT_BSP_PA_GB_R0614.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HCMT_BSP_PA_GB_R0614-SPRTX, sy-vline,
WA_HCMT_BSP_PA_GB_R0614-ITBLD, sy-vline,
WA_HCMT_BSP_PA_GB_R0614-ITXEX, sy-vline,
WA_HCMT_BSP_PA_GB_R0614-BEGDA, sy-vline,
WA_HCMT_BSP_PA_GB_R0614-ENDDA, sy-vline,
WA_HCMT_BSP_PA_GB_R0614-PREAS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HCMT_BSP_PA_GB_R0614 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HCMT_BSP_PA_GB_R0614 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HCMT_BSP_PA_GB_R0614 INTO WA_HCMT_BSP_PA_GB_R0614. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HCMT_BSP_PA_GB_R0614_STR,
OBJECT_KEY TYPE STRING,
PERNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
SPRPS TYPE STRING,
SPRTX TYPE STRING,
ITBLD TYPE STRING,
ITXEX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
PREAS TYPE STRING,
STAFF TYPE STRING,
DATEH TYPE STRING,
PROFQ TYPE STRING,
RESAC TYPE STRING,
ABLWE TYPE STRING,
TCHWL TYPE STRING,
SENPH TYPE STRING,
SREAD TYPE STRING,
PRIID TYPE STRING,
INSTTEXT TYPE STRING,
EMPPR TYPE STRING,
EMPPREYRT TYPE STRING,
RESA2 TYPE STRING,
UOARAE TYPE STRING,
SUBMISSION TYPE STRING,
DISABLE1 TYPE STRING,
DISABLE2 TYPE STRING,
ACTCHQ1 TYPE STRING,
ACTCHQ2 TYPE STRING,
ACTCHQ3 TYPE STRING,
ACTCHQ4 TYPE STRING,
ACTCHQ5 TYPE STRING,
ACTCHQ6 TYPE STRING,
ACTLEAVE TYPE STRING,
LOCLEAVE TYPE STRING,
ECRSTAT TYPE STRING,
RESAST TYPE STRING,
DISABLE3 TYPE STRING,
GENDERID TYPE STRING,
NATIOND1 TYPE STRING,
NATIOND2 TYPE STRING,
SEXORT TYPE STRING,
CDIS1 TYPE STRING,
CDIS2 TYPE STRING,
CDIS3 TYPE STRING,
ORCID TYPE STRING,
ORCIDTEXT TYPE STRING,
CDIS1TEXT TYPE STRING,
CDIS2TEXT TYPE STRING,
CDIS3TEXT TYPE STRING,
GENRA TYPE STRING,
GENRATEXT TYPE STRING,
SEXID TYPE STRING,
GOVNR TYPE STRING,
GOVSD TYPE STRING,
GOVED TYPE STRING,
GOVEE TYPE STRING,
HECOS1 TYPE STRING,
HECOS2 TYPE STRING,
HECOS3 TYPE STRING,
HECOS4 TYPE STRING,
HECOS5 TYPE STRING,
HECOS1TEXT TYPE STRING,
HECOS2TEXT TYPE STRING,
HECOS3TEXT TYPE STRING,
HECOS4TEXT TYPE STRING,
HECOS5TEXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_HCMT_BSP_PA_GB_R0614_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-OBJECT_KEY sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-PERNR sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-AEDTM sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-UNAME sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-SPRPS sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-SPRTX sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-ITBLD sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-ITXEX sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-BEGDA sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-ENDDA sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-PREAS sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-STAFF sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-DATEH sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-PROFQ sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-RESAC sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-ABLWE sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-TCHWL sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-SENPH sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-SREAD sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-PRIID sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-INSTTEXT sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-EMPPR sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-EMPPREYRT sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-RESA2 sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-UOARAE sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-SUBMISSION sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-DISABLE1 sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-DISABLE2 sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-ACTCHQ1 sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-ACTCHQ2 sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-ACTCHQ3 sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-ACTCHQ4 sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-ACTCHQ5 sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-ACTCHQ6 sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-ACTLEAVE sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-LOCLEAVE sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-ECRSTAT sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-RESAST sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-DISABLE3 sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-GENDERID sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-NATIOND1 sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-NATIOND2 sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-SEXORT sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-CDIS1 sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-CDIS2 sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-CDIS3 sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-ORCID sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-ORCIDTEXT sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-CDIS1TEXT sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-CDIS2TEXT sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-CDIS3TEXT sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-GENRA sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-GENRATEXT sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-SEXID sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-GOVNR sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-GOVSD sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-GOVED sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-GOVEE sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-HECOS1 sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-HECOS2 sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-HECOS3 sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-HECOS4 sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-HECOS5 sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-HECOS1TEXT sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-HECOS2TEXT sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-HECOS3TEXT sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-HECOS4TEXT sy-vline
WA_HCMT_BSP_PA_GB_R0614_STR-HECOS5TEXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.