ABAP Select data from SAP table HCMT_BSP_PA_GB_R0048 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HCMT_BSP_PA_GB_R0048 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HCMT_BSP_PA_GB_R0048. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HCMT_BSP_PA_GB_R0048 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HCMT_BSP_PA_GB_R0048 TYPE STANDARD TABLE OF HCMT_BSP_PA_GB_R0048,
      WA_HCMT_BSP_PA_GB_R0048 TYPE HCMT_BSP_PA_GB_R0048,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HCMT_BSP_PA_GB_R0048> TYPE HCMT_BSP_PA_GB_R0048.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HCMT_BSP_PA_GB_R0048.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HCMT_BSP_PA_GB_R0048
  INTO TABLE IT_HCMT_BSP_PA_GB_R0048.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HCMT_BSP_PA_GB_R0048
*  INTO TABLE @DATA(IT_HCMT_BSP_PA_GB_R00482).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HCMT_BSP_PA_GB_R0048 INDEX 1 INTO DATA(WA_HCMT_BSP_PA_GB_R00482).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HCMT_BSP_PA_GB_R0048 ASSIGNING <HCMT_BSP_PA_GB_R0048>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HCMT_BSP_PA_GB_R0048>-OBJECT_KEY = 1.
<HCMT_BSP_PA_GB_R0048>-PERNR = 1.
<HCMT_BSP_PA_GB_R0048>-AEDTM = 1.
<HCMT_BSP_PA_GB_R0048>-UNAME = 1.
<HCMT_BSP_PA_GB_R0048>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_HCMT_BSP_PA_GB_R0048 INTO WA_HCMT_BSP_PA_GB_R0048.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HCMT_BSP_PA_GB_R0048-SPRTX, sy-vline,
WA_HCMT_BSP_PA_GB_R0048-ITBLD, sy-vline,
WA_HCMT_BSP_PA_GB_R0048-ITXEX, sy-vline,
WA_HCMT_BSP_PA_GB_R0048-BEGDA, sy-vline,
WA_HCMT_BSP_PA_GB_R0048-ENDDA, sy-vline,
WA_HCMT_BSP_PA_GB_R0048-ANTXT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HCMT_BSP_PA_GB_R0048 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HCMT_BSP_PA_GB_R0048 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HCMT_BSP_PA_GB_R0048 INTO WA_HCMT_BSP_PA_GB_R0048. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HCMT_BSP_PA_GB_R0048_STR,
OBJECT_KEY TYPE STRING,
PERNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
SPRPS TYPE STRING,
SPRTX TYPE STRING,
ITBLD TYPE STRING,
ITXEX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
ANTXT TYPE STRING,
ASTAT TYPE STRING,
STEXT TYPE STRING,
BEWNR TYPE STRING,
ABLAD TYPE STRING,
AUSGD TYPE STRING,
EINRD TYPE STRING,
PASSN TYPE STRING,
VISAT TYPE STRING,
VTEXT TYPE STRING,
VISAS TYPE STRING,
PRTXT TYPE STRING,
PTEXT TYPE STRING,
PRFID TYPE STRING,
PPLND TYPE STRING,
LANDX TYPE STRING,
WPFUN TYPE STRING,
WPEND TYPE STRING,
VIBEG TYPE STRING,
AUSBE TYPE STRING,
UKNIC TYPE STRING,
REASP TYPE STRING,
SUBTY TYPE STRING,
INFTY TYPE STRING,
OBJPS TYPE STRING,
PASS2 TYPE STRING,
PANAT TYPE STRING,
NATID TYPE STRING,
AWSER TYPE STRING,
AWSRN TYPE STRING,
WRSER TYPE STRING,
WRSRN TYPE STRING,
WRSAF TYPE STRING,
PVNCH TYPE STRING,
UKNI2 TYPE STRING,
ORTWC TYPE STRING,END OF T_EKKO_STR. DATA: WA_HCMT_BSP_PA_GB_R0048_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-OBJECT_KEY sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-PERNR sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-AEDTM sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-UNAME sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-SPRPS sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-SPRTX sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-ITBLD sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-ITXEX sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-BEGDA sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-ENDDA sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-ANTXT sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-ASTAT sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-STEXT sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-BEWNR sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-ABLAD sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-AUSGD sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-EINRD sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-PASSN sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-VISAT sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-VTEXT sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-VISAS sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-PRTXT sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-PTEXT sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-PRFID sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-PPLND sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-LANDX sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-WPFUN sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-WPEND sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-VIBEG sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-AUSBE sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-UKNIC sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-REASP sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-SUBTY sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-INFTY sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-OBJPS sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-PASS2 sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-PANAT sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-NATID sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-AWSER sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-AWSRN sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-WRSER sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-WRSRN sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-WRSAF sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-PVNCH sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-UKNI2 sy-vline
WA_HCMT_BSP_PA_GB_R0048_STR-ORTWC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.