ABAP Select data from SAP table HCMT_BSP_PA_FP_R0861 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HCMT_BSP_PA_FP_R0861 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HCMT_BSP_PA_FP_R0861. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HCMT_BSP_PA_FP_R0861 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HCMT_BSP_PA_FP_R0861 TYPE STANDARD TABLE OF HCMT_BSP_PA_FP_R0861,
      WA_HCMT_BSP_PA_FP_R0861 TYPE HCMT_BSP_PA_FP_R0861,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HCMT_BSP_PA_FP_R0861> TYPE HCMT_BSP_PA_FP_R0861.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HCMT_BSP_PA_FP_R0861.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HCMT_BSP_PA_FP_R0861
  INTO TABLE IT_HCMT_BSP_PA_FP_R0861.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HCMT_BSP_PA_FP_R0861
*  INTO TABLE @DATA(IT_HCMT_BSP_PA_FP_R08612).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HCMT_BSP_PA_FP_R0861 INDEX 1 INTO DATA(WA_HCMT_BSP_PA_FP_R08612).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HCMT_BSP_PA_FP_R0861 ASSIGNING <HCMT_BSP_PA_FP_R0861>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HCMT_BSP_PA_FP_R0861>-OBJECT_KEY = 1.
<HCMT_BSP_PA_FP_R0861>-PERNR = 1.
<HCMT_BSP_PA_FP_R0861>-AEDTM = 1.
<HCMT_BSP_PA_FP_R0861>-UNAME = 1.
<HCMT_BSP_PA_FP_R0861>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_HCMT_BSP_PA_FP_R0861 INTO WA_HCMT_BSP_PA_FP_R0861.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HCMT_BSP_PA_FP_R0861-SPRTX, sy-vline,
WA_HCMT_BSP_PA_FP_R0861-ITBLD, sy-vline,
WA_HCMT_BSP_PA_FP_R0861-ITXEX, sy-vline,
WA_HCMT_BSP_PA_FP_R0861-BEGDA, sy-vline,
WA_HCMT_BSP_PA_FP_R0861-ENDDA, sy-vline,
WA_HCMT_BSP_PA_FP_R0861-AWADG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HCMT_BSP_PA_FP_R0861 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HCMT_BSP_PA_FP_R0861 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HCMT_BSP_PA_FP_R0861 INTO WA_HCMT_BSP_PA_FP_R0861. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HCMT_BSP_PA_FP_R0861_STR,
OBJECT_KEY TYPE STRING,
PERNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
SPRPS TYPE STRING,
SPRTX TYPE STRING,
ITBLD TYPE STRING,
ITXEX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
AWADG TYPE STRING,
AGTXT TYPE STRING,
MOTIF TYPE STRING,
MOTXT TYPE STRING,
BEPRO TYPE STRING,
TITLE TYPE STRING,
TITXT TYPE STRING,
AWADT TYPE STRING,
AWTXT TYPE STRING,
LAWRF TYPE STRING,
COLLE TYPE STRING,
AUTHO TYPE STRING,
AUTXT TYPE STRING,
AUTGV TYPE STRING,
GVTXT TYPE STRING,
STATU TYPE STRING,
DCDAT TYPE STRING,
DADAT TYPE STRING,
GRADE TYPE STRING,
GRTXT TYPE STRING,
NIVAU TYPE STRING,
ORTYP TYPE STRING,
ORNID TYPE STRING,
ORTXT TYPE STRING,
ACQPT TYPE STRING,
POINT TYPE STRING,
DURGR TYPE STRING,
DURER TYPE STRING,
PREGR TYPE STRING,
GPTXT TYPE STRING,
STTXT TYPE STRING,
LRTXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_HCMT_BSP_PA_FP_R0861_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-OBJECT_KEY sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-PERNR sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-AEDTM sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-UNAME sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-SPRPS sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-SPRTX sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-ITBLD sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-ITXEX sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-BEGDA sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-ENDDA sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-AWADG sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-AGTXT sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-MOTIF sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-MOTXT sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-BEPRO sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-TITLE sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-TITXT sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-AWADT sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-AWTXT sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-LAWRF sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-COLLE sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-AUTHO sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-AUTXT sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-AUTGV sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-GVTXT sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-STATU sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-DCDAT sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-DADAT sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-GRADE sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-GRTXT sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-NIVAU sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-ORTYP sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-ORNID sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-ORTXT sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-ACQPT sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-POINT sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-DURGR sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-DURER sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-PREGR sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-GPTXT sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-STTXT sy-vline
WA_HCMT_BSP_PA_FP_R0861_STR-LRTXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.