ABAP Select data from SAP table HCMT_BSP_PA_FI_R0442 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HCMT_BSP_PA_FI_R0442 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HCMT_BSP_PA_FI_R0442. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HCMT_BSP_PA_FI_R0442 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HCMT_BSP_PA_FI_R0442 TYPE STANDARD TABLE OF HCMT_BSP_PA_FI_R0442,
      WA_HCMT_BSP_PA_FI_R0442 TYPE HCMT_BSP_PA_FI_R0442,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HCMT_BSP_PA_FI_R0442> TYPE HCMT_BSP_PA_FI_R0442.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HCMT_BSP_PA_FI_R0442.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HCMT_BSP_PA_FI_R0442
  INTO TABLE IT_HCMT_BSP_PA_FI_R0442.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HCMT_BSP_PA_FI_R0442
*  INTO TABLE @DATA(IT_HCMT_BSP_PA_FI_R04422).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HCMT_BSP_PA_FI_R0442 INDEX 1 INTO DATA(WA_HCMT_BSP_PA_FI_R04422).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HCMT_BSP_PA_FI_R0442 ASSIGNING <HCMT_BSP_PA_FI_R0442>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HCMT_BSP_PA_FI_R0442>-OBJECT_KEY = 1.
<HCMT_BSP_PA_FI_R0442>-PERNR = 1.
<HCMT_BSP_PA_FI_R0442>-AEDTM = 1.
<HCMT_BSP_PA_FI_R0442>-UNAME = 1.
<HCMT_BSP_PA_FI_R0442>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_HCMT_BSP_PA_FI_R0442 INTO WA_HCMT_BSP_PA_FI_R0442.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HCMT_BSP_PA_FI_R0442-SPRTX, sy-vline,
WA_HCMT_BSP_PA_FI_R0442-ITBLD, sy-vline,
WA_HCMT_BSP_PA_FI_R0442-ITXEX, sy-vline,
WA_HCMT_BSP_PA_FI_R0442-BEGDA, sy-vline,
WA_HCMT_BSP_PA_FI_R0442-ENDDA, sy-vline,
WA_HCMT_BSP_PA_FI_R0442-VEHCL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HCMT_BSP_PA_FI_R0442 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HCMT_BSP_PA_FI_R0442 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HCMT_BSP_PA_FI_R0442 INTO WA_HCMT_BSP_PA_FI_R0442. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field SPRSL CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_HCMT_BSP_PA_FI_R0442-SPRSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HCMT_BSP_PA_FI_R0442-SPRSL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HCMT_BSP_PA_FI_R0442_STR,
OBJECT_KEY TYPE STRING,
PERNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
SPRPS TYPE STRING,
SPRTX TYPE STRING,
ITBLD TYPE STRING,
ITXEX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
VEHCL TYPE STRING,
STEXT TYPE STRING,
FACTO TYPE STRING,
FTEXT TYPE STRING,
MODEL TYPE STRING,
MTEXT TYPE STRING,
REGNO TYPE STRING,
RGNDA TYPE STRING,
RANGE TYPE STRING,
SPRSL TYPE STRING,
LISTP TYPE STRING,
CRNC1 TYPE STRING,
DSCNT TYPE STRING,
PRCNT TYPE STRING,
ACCSS TYPE STRING,
CRNC2 TYPE STRING,
ADDAC TYPE STRING,
CRNCY1 TYPE STRING,
PAIDP TYPE STRING,
CRNCY2 TYPE STRING,
ONEPD TYPE STRING,
CRNCY5 TYPE STRING,
CALCB TYPE STRING,
BNFTV TYPE STRING,
CRNCY3 TYPE STRING,
REGPD TYPE STRING,
CRNCY TYPE STRING,
PAYMO TYPE STRING,
MODTX TYPE STRING,
CARRG TYPE STRING,
PKWTX TYPE STRING,
PERTX TYPE STRING,
POLLC TYPE STRING,
PCTXT TYPE STRING,
PRVDR TYPE STRING,
DUTDR TYPE STRING,END OF T_EKKO_STR. DATA: WA_HCMT_BSP_PA_FI_R0442_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-OBJECT_KEY sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-PERNR sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-AEDTM sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-UNAME sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-SPRPS sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-SPRTX sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-ITBLD sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-ITXEX sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-BEGDA sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-ENDDA sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-VEHCL sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-STEXT sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-FACTO sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-FTEXT sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-MODEL sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-MTEXT sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-REGNO sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-RGNDA sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-RANGE sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-SPRSL sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-LISTP sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-CRNC1 sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-DSCNT sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-PRCNT sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-ACCSS sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-CRNC2 sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-ADDAC sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-CRNCY1 sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-PAIDP sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-CRNCY2 sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-ONEPD sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-CRNCY5 sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-CALCB sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-BNFTV sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-CRNCY3 sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-REGPD sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-CRNCY sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-PAYMO sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-MODTX sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-CARRG sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-PKWTX sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-PERTX sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-POLLC sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-PCTXT sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-PRVDR sy-vline
WA_HCMT_BSP_PA_FI_R0442_STR-DUTDR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.