ABAP Select data from SAP table HCMT_BSP_PA_ES_R0887 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HCMT_BSP_PA_ES_R0887 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HCMT_BSP_PA_ES_R0887. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HCMT_BSP_PA_ES_R0887 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HCMT_BSP_PA_ES_R0887 TYPE STANDARD TABLE OF HCMT_BSP_PA_ES_R0887,
      WA_HCMT_BSP_PA_ES_R0887 TYPE HCMT_BSP_PA_ES_R0887,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HCMT_BSP_PA_ES_R0887> TYPE HCMT_BSP_PA_ES_R0887.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HCMT_BSP_PA_ES_R0887.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HCMT_BSP_PA_ES_R0887
  INTO TABLE IT_HCMT_BSP_PA_ES_R0887.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HCMT_BSP_PA_ES_R0887
*  INTO TABLE @DATA(IT_HCMT_BSP_PA_ES_R08872).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HCMT_BSP_PA_ES_R0887 INDEX 1 INTO DATA(WA_HCMT_BSP_PA_ES_R08872).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HCMT_BSP_PA_ES_R0887 ASSIGNING <HCMT_BSP_PA_ES_R0887>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HCMT_BSP_PA_ES_R0887>-OBJECT_KEY = 1.
<HCMT_BSP_PA_ES_R0887>-PERNR = 1.
<HCMT_BSP_PA_ES_R0887>-AEDTM = 1.
<HCMT_BSP_PA_ES_R0887>-UNAME = 1.
<HCMT_BSP_PA_ES_R0887>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_HCMT_BSP_PA_ES_R0887 INTO WA_HCMT_BSP_PA_ES_R0887.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HCMT_BSP_PA_ES_R0887-SPRTX, sy-vline,
WA_HCMT_BSP_PA_ES_R0887-ITBLD, sy-vline,
WA_HCMT_BSP_PA_ES_R0887-ITXEX, sy-vline,
WA_HCMT_BSP_PA_ES_R0887-BEGDA, sy-vline,
WA_HCMT_BSP_PA_ES_R0887-ENDDA, sy-vline,
WA_HCMT_BSP_PA_ES_R0887-GMTYP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HCMT_BSP_PA_ES_R0887 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HCMT_BSP_PA_ES_R0887 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HCMT_BSP_PA_ES_R0887 INTO WA_HCMT_BSP_PA_ES_R0887. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HCMT_BSP_PA_ES_R0887_STR,
OBJECT_KEY TYPE STRING,
PERNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
SPRPS TYPE STRING,
SPRTX TYPE STRING,
ITBLD TYPE STRING,
ITXEX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
GMTYP TYPE STRING,
GMCID TYPE STRING,
GMSEQ TYPE STRING,
GMBLG TYPE STRING,
OPKEN TYPE STRING,
GMDEB TYPE STRING,
GMSUB TYPE STRING,
GMRTE TYPE STRING,
GMRED TYPE STRING,
WAERS TYPE STRING,
GMIPR TYPE STRING,
EMFSL TYPE STRING,
EMFTX TYPE STRING,
BANKS TYPE STRING,
BKORT TYPE STRING,
BKPLZ TYPE STRING,
BANKL TYPE STRING,
SWIFT TYPE STRING,
BANKN TYPE STRING,
BKONT TYPE STRING,
DTAWS TYPE STRING,
STCD1 TYPE STRING,
BKREF TYPE STRING,
ZLSCH TYPE STRING,
ZWECK TYPE STRING,
STRAS TYPE STRING,
STATE TYPE STRING,
IBAN TYPE STRING,
INERB TYPE STRING,
GMTYP_FRAME TYPE STRING,
GMTYP_TXT TYPE STRING,
GMCID_UI TYPE STRING,
GMAMD TYPE STRING,
WAERSGMAMD TYPE STRING,
GMBAS TYPE STRING,
WAERSGMBAS TYPE STRING,
GMCPR TYPE STRING,
WAERSGMCPR TYPE STRING,
WAERSGMSUB TYPE STRING,
WAERSGMDEB TYPE STRING,
SBTTX TYPE STRING,
GMBLG_TXT TYPE STRING,
IBAN00 TYPE STRING,
GMTOT TYPE STRING,
WAERSGMTOT TYPE STRING,
GMNBT TYPE STRING,
WAERSGMNBT TYPE STRING,
GMNYD TYPE STRING,
WAERSGMNYD TYPE STRING,
INPER_UI TYPE STRING,
IPEND TYPE STRING,
IBAN01 TYPE STRING,
IBAN02 TYPE STRING,
IBAN03 TYPE STRING,
IBAN04 TYPE STRING,
IBAN05 TYPE STRING,
IBAN06 TYPE STRING,
IBAN07 TYPE STRING,
IBAN08 TYPE STRING,
IBAN09 TYPE STRING,
IBAN_VALFR TYPE STRING,
BANKA TYPE STRING,
PERC01 TYPE STRING,
PERC02 TYPE STRING,END OF T_EKKO_STR. DATA: WA_HCMT_BSP_PA_ES_R0887_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-OBJECT_KEY sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-PERNR sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-AEDTM sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-UNAME sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-SPRPS sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-SPRTX sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-ITBLD sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-ITXEX sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-BEGDA sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-ENDDA sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-GMTYP sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-GMCID sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-GMSEQ sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-GMBLG sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-OPKEN sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-GMDEB sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-GMSUB sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-GMRTE sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-GMRED sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-WAERS sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-GMIPR sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-EMFSL sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-EMFTX sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-BANKS sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-BKORT sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-BKPLZ sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-BANKL sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-SWIFT sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-BANKN sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-BKONT sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-DTAWS sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-STCD1 sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-BKREF sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-ZLSCH sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-ZWECK sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-STRAS sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-STATE sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-IBAN sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-INERB sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-GMTYP_FRAME sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-GMTYP_TXT sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-GMCID_UI sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-GMAMD sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-WAERSGMAMD sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-GMBAS sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-WAERSGMBAS sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-GMCPR sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-WAERSGMCPR sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-WAERSGMSUB sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-WAERSGMDEB sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-SBTTX sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-GMBLG_TXT sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-IBAN00 sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-GMTOT sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-WAERSGMTOT sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-GMNBT sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-WAERSGMNBT sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-GMNYD sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-WAERSGMNYD sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-INPER_UI sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-IPEND sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-IBAN01 sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-IBAN02 sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-IBAN03 sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-IBAN04 sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-IBAN05 sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-IBAN06 sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-IBAN07 sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-IBAN08 sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-IBAN09 sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-IBAN_VALFR sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-BANKA sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-PERC01 sy-vline
WA_HCMT_BSP_PA_ES_R0887_STR-PERC02 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.