ABAP Select data from SAP table HCMT_BSP_PA_EG_R3390 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HCMT_BSP_PA_EG_R3390 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HCMT_BSP_PA_EG_R3390. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HCMT_BSP_PA_EG_R3390 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HCMT_BSP_PA_EG_R3390 TYPE STANDARD TABLE OF HCMT_BSP_PA_EG_R3390,
      WA_HCMT_BSP_PA_EG_R3390 TYPE HCMT_BSP_PA_EG_R3390,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HCMT_BSP_PA_EG_R3390> TYPE HCMT_BSP_PA_EG_R3390.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HCMT_BSP_PA_EG_R3390.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HCMT_BSP_PA_EG_R3390
  INTO TABLE IT_HCMT_BSP_PA_EG_R3390.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HCMT_BSP_PA_EG_R3390
*  INTO TABLE @DATA(IT_HCMT_BSP_PA_EG_R33902).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HCMT_BSP_PA_EG_R3390 INDEX 1 INTO DATA(WA_HCMT_BSP_PA_EG_R33902).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HCMT_BSP_PA_EG_R3390 ASSIGNING <HCMT_BSP_PA_EG_R3390>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HCMT_BSP_PA_EG_R3390>-OBJECT_KEY = 1.
<HCMT_BSP_PA_EG_R3390>-PERNR = 1.
<HCMT_BSP_PA_EG_R3390>-AEDTM = 1.
<HCMT_BSP_PA_EG_R3390>-UNAME = 1.
<HCMT_BSP_PA_EG_R3390>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_HCMT_BSP_PA_EG_R3390 INTO WA_HCMT_BSP_PA_EG_R3390.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HCMT_BSP_PA_EG_R3390-SPRTX, sy-vline,
WA_HCMT_BSP_PA_EG_R3390-ITBLD, sy-vline,
WA_HCMT_BSP_PA_EG_R3390-ITXEX, sy-vline,
WA_HCMT_BSP_PA_EG_R3390-BEGDA, sy-vline,
WA_HCMT_BSP_PA_EG_R3390-ENDDA, sy-vline,
WA_HCMT_BSP_PA_EG_R3390-SIEXC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HCMT_BSP_PA_EG_R3390 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HCMT_BSP_PA_EG_R3390 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HCMT_BSP_PA_EG_R3390 INTO WA_HCMT_BSP_PA_EG_R3390. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HCMT_BSP_PA_EG_R3390_STR,
OBJECT_KEY TYPE STRING,
PERNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
SPRPS TYPE STRING,
SPRTX TYPE STRING,
ITBLD TYPE STRING,
ITXEX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
SIEXC TYPE STRING,
EGSIX TYPE STRING,
EGSTX TYPE STRING,
SIEDT TYPE STRING,
SINUM TYPE STRING,
SIOFF TYPE STRING,
SIOTX TYPE STRING,
SIFTY TYPE STRING,
SIFTT TYPE STRING,
EGSIP TYPE STRING,
EGPTX TYPE STRING,END OF T_EKKO_STR. DATA: WA_HCMT_BSP_PA_EG_R3390_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HCMT_BSP_PA_EG_R3390_STR-OBJECT_KEY sy-vline
WA_HCMT_BSP_PA_EG_R3390_STR-PERNR sy-vline
WA_HCMT_BSP_PA_EG_R3390_STR-AEDTM sy-vline
WA_HCMT_BSP_PA_EG_R3390_STR-UNAME sy-vline
WA_HCMT_BSP_PA_EG_R3390_STR-SPRPS sy-vline
WA_HCMT_BSP_PA_EG_R3390_STR-SPRTX sy-vline
WA_HCMT_BSP_PA_EG_R3390_STR-ITBLD sy-vline
WA_HCMT_BSP_PA_EG_R3390_STR-ITXEX sy-vline
WA_HCMT_BSP_PA_EG_R3390_STR-BEGDA sy-vline
WA_HCMT_BSP_PA_EG_R3390_STR-ENDDA sy-vline
WA_HCMT_BSP_PA_EG_R3390_STR-SIEXC sy-vline
WA_HCMT_BSP_PA_EG_R3390_STR-EGSIX sy-vline
WA_HCMT_BSP_PA_EG_R3390_STR-EGSTX sy-vline
WA_HCMT_BSP_PA_EG_R3390_STR-SIEDT sy-vline
WA_HCMT_BSP_PA_EG_R3390_STR-SINUM sy-vline
WA_HCMT_BSP_PA_EG_R3390_STR-SIOFF sy-vline
WA_HCMT_BSP_PA_EG_R3390_STR-SIOTX sy-vline
WA_HCMT_BSP_PA_EG_R3390_STR-SIFTY sy-vline
WA_HCMT_BSP_PA_EG_R3390_STR-SIFTT sy-vline
WA_HCMT_BSP_PA_EG_R3390_STR-EGSIP sy-vline
WA_HCMT_BSP_PA_EG_R3390_STR-EGPTX sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.