ABAP Select data from SAP table HCMT_BSP_PA_DE_R0700_DSAB into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HCMT_BSP_PA_DE_R0700_DSAB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HCMT_BSP_PA_DE_R0700_DSAB. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HCMT_BSP_PA_DE_R0700_DSAB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HCMT_BSP_PA_DE_R0700_DSAB TYPE STANDARD TABLE OF HCMT_BSP_PA_DE_R0700_DSAB,
      WA_HCMT_BSP_PA_DE_R0700_DSAB TYPE HCMT_BSP_PA_DE_R0700_DSAB,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HCMT_BSP_PA_DE_R0700_DSAB> TYPE HCMT_BSP_PA_DE_R0700_DSAB.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HCMT_BSP_PA_DE_R0700_DSAB.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HCMT_BSP_PA_DE_R0700_DSAB
  INTO TABLE IT_HCMT_BSP_PA_DE_R0700_DSAB.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HCMT_BSP_PA_DE_R0700_DSAB
*  INTO TABLE @DATA(IT_HCMT_BSP_PA_DE_R0700_DSAB2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HCMT_BSP_PA_DE_R0700_DSAB INDEX 1 INTO DATA(WA_HCMT_BSP_PA_DE_R0700_DSAB2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HCMT_BSP_PA_DE_R0700_DSAB ASSIGNING <HCMT_BSP_PA_DE_R0700_DSAB>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HCMT_BSP_PA_DE_R0700_DSAB>-LAND1 = 1.
<HCMT_BSP_PA_DE_R0700_DSAB>-BPLZ = 1.
<HCMT_BSP_PA_DE_R0700_DSAB>-BORT = 1.
<HCMT_BSP_PA_DE_R0700_DSAB>-DRUCKEN = 1.
<HCMT_BSP_PA_DE_R0700_DSAB>-AVEND = 1.
ENDLOOP.

LOOP AT IT_HCMT_BSP_PA_DE_R0700_DSAB INTO WA_HCMT_BSP_PA_DE_R0700_DSAB.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HCMT_BSP_PA_DE_R0700_DSAB-BVEND, sy-vline,
WA_HCMT_BSP_PA_DE_R0700_DSAB-AVBFR, sy-vline,
WA_HCMT_BSP_PA_DE_R0700_DSAB-AVBFSCHR, sy-vline,
WA_HCMT_BSP_PA_DE_R0700_DSAB-AVBFURSP, sy-vline,
WA_HCMT_BSP_PA_DE_R0700_DSAB-AVBFABSCHL, sy-vline,
WA_HCMT_BSP_PA_DE_R0700_DSAB-VLBAV, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HCMT_BSP_PA_DE_R0700_DSAB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HCMT_BSP_PA_DE_R0700_DSAB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HCMT_BSP_PA_DE_R0700_DSAB INTO WA_HCMT_BSP_PA_DE_R0700_DSAB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HCMT_BSP_PA_DE_R0700_DSAB_STR,
LAND1 TYPE STRING,
BPLZ TYPE STRING,
BORT TYPE STRING,
DRUCKEN TYPE STRING,
AVEND TYPE STRING,
BVEND TYPE STRING,
AVBFR TYPE STRING,
AVBFSCHR TYPE STRING,
AVBFURSP TYPE STRING,
AVBFABSCHL TYPE STRING,
VLBAV TYPE STRING,
AVBFABVL TYPE STRING,
BFHG TYPE STRING,
AVBFRL TYPE STRING,
AVKUEAM TYPE STRING,
AVUWFWZ TYPE STRING,
AVUWFWZBEG TYPE STRING,
AVKUEDU TYPE STRING,
AVKUESCH TYPE STRING,
AVKUEBETR TYPE STRING,
AVKUESCHUKL TYPE STRING,
AVKUEZUST TYPE STRING,
AVKUEAL TYPE STRING,
AVKUEALAM TYPE STRING,
AVAMDAT TYPE STRING,
AVKUEZVB TYPE STRING,
SAW TYPE STRING,
SAWPRSC TYPE STRING,
KF TYPE STRING,
KFZE TYPE STRING,
KFBZ TYPE STRING,
KA TYPE STRING,
KAU TYPE STRING,
KAUAUG TYPE STRING,
ABF TYPE STRING,
D_ABFHOE TYPE STRING,
ABFMONAT TYPE STRING,
ABFGEZ TYPE STRING,
AVENLZ TYPE STRING,
BVEGEN TYPE STRING,
BVEGENB TYPE STRING,
AVENUAG TYPE STRING,
BVENUR TYPE STRING,
AVENVL TYPE STRING,
AVENVGB TYPE STRING,
D_AVENVG TYPE STRING,
AVENLZG TYPE STRING,
AGKUEAM TYPE STRING,
AGKUEZU TYPE STRING,
OKGL TYPE STRING,
OKGLFG TYPE STRING,END OF T_EKKO_STR. DATA: WA_HCMT_BSP_PA_DE_R0700_DSAB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-LAND1 sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-BPLZ sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-BORT sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-DRUCKEN sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AVEND sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-BVEND sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AVBFR sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AVBFSCHR sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AVBFURSP sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AVBFABSCHL sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-VLBAV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AVBFABVL sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-BFHG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AVBFRL sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AVKUEAM sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AVUWFWZ sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AVUWFWZBEG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AVKUEDU sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AVKUESCH sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AVKUEBETR sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AVKUESCHUKL sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AVKUEZUST sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AVKUEAL sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AVKUEALAM sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AVAMDAT sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AVKUEZVB sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-SAW sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-SAWPRSC sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-KF sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-KFZE sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-KFBZ sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-KA sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-KAU sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-KAUAUG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-ABF sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-D_ABFHOE sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-ABFMONAT sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-ABFGEZ sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AVENLZ sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-BVEGEN sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-BVEGENB sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AVENUAG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-BVENUR sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AVENVL sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AVENVGB sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-D_AVENVG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AVENLZG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AGKUEAM sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-AGKUEZU sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-OKGL sy-vline
WA_HCMT_BSP_PA_DE_R0700_DSAB_STR-OKGLFG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.