ABAP Select data from SAP table HCMT_BSP_PA_DE_R0700_DBGZ into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HCMT_BSP_PA_DE_R0700_DBGZ table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HCMT_BSP_PA_DE_R0700_DBGZ. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HCMT_BSP_PA_DE_R0700_DBGZ table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HCMT_BSP_PA_DE_R0700_DBGZ TYPE STANDARD TABLE OF HCMT_BSP_PA_DE_R0700_DBGZ,
      WA_HCMT_BSP_PA_DE_R0700_DBGZ TYPE HCMT_BSP_PA_DE_R0700_DBGZ,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HCMT_BSP_PA_DE_R0700_DBGZ> TYPE HCMT_BSP_PA_DE_R0700_DBGZ.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HCMT_BSP_PA_DE_R0700_DBGZ.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HCMT_BSP_PA_DE_R0700_DBGZ
  INTO TABLE IT_HCMT_BSP_PA_DE_R0700_DBGZ.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HCMT_BSP_PA_DE_R0700_DBGZ
*  INTO TABLE @DATA(IT_HCMT_BSP_PA_DE_R0700_DBGZ2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HCMT_BSP_PA_DE_R0700_DBGZ INDEX 1 INTO DATA(WA_HCMT_BSP_PA_DE_R0700_DBGZ2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HCMT_BSP_PA_DE_R0700_DBGZ ASSIGNING <HCMT_BSP_PA_DE_R0700_DBGZ>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HCMT_BSP_PA_DE_R0700_DBGZ>-KENNZGLZ = 1.
<HCMT_BSP_PA_DE_R0700_DBGZ>-M_KENNZGLZ = 1.
<HCMT_BSP_PA_DE_R0700_DBGZ>-D_GAEG = 1.
<HCMT_BSP_PA_DE_R0700_DBGZ>-D_M_GAEG = 1.
<HCMT_BSP_PA_DE_R0700_DBGZ>-SW_GAEG = 1.
ENDLOOP.

LOOP AT IT_HCMT_BSP_PA_DE_R0700_DBGZ INTO WA_HCMT_BSP_PA_DE_R0700_DBGZ.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HCMT_BSP_PA_DE_R0700_DBGZ-D_EGAEG, sy-vline,
WA_HCMT_BSP_PA_DE_R0700_DBGZ-D_M_EGAEG, sy-vline,
WA_HCMT_BSP_PA_DE_R0700_DBGZ-SW_EGAEG, sy-vline,
WA_HCMT_BSP_PA_DE_R0700_DBGZ-D_LFDEG, sy-vline,
WA_HCMT_BSP_PA_DE_R0700_DBGZ-D_M_LFDEG, sy-vline,
WA_HCMT_BSP_PA_DE_R0700_DBGZ-SW_LFDEG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HCMT_BSP_PA_DE_R0700_DBGZ you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HCMT_BSP_PA_DE_R0700_DBGZ TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HCMT_BSP_PA_DE_R0700_DBGZ INTO WA_HCMT_BSP_PA_DE_R0700_DBGZ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HCMT_BSP_PA_DE_R0700_DBGZ_STR,
KENNZGLZ TYPE STRING,
M_KENNZGLZ TYPE STRING,
D_GAEG TYPE STRING,
D_M_GAEG TYPE STRING,
SW_GAEG TYPE STRING,
D_EGAEG TYPE STRING,
D_M_EGAEG TYPE STRING,
SW_EGAEG TYPE STRING,
D_LFDEG TYPE STRING,
D_M_LFDEG TYPE STRING,
SW_LFDEG TYPE STRING,
D_EZEG TYPE STRING,
D_M_EZEG TYPE STRING,
SW_EZEG TYPE STRING,
D_BBGRUKUG TYPE STRING,
D_M_BBGRUKUG TYPE STRING,
SW_BBGRUKUG TYPE STRING,END OF T_EKKO_STR. DATA: WA_HCMT_BSP_PA_DE_R0700_DBGZ_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBGZ_STR-KENNZGLZ sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBGZ_STR-M_KENNZGLZ sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBGZ_STR-D_GAEG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBGZ_STR-D_M_GAEG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBGZ_STR-SW_GAEG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBGZ_STR-D_EGAEG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBGZ_STR-D_M_EGAEG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBGZ_STR-SW_EGAEG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBGZ_STR-D_LFDEG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBGZ_STR-D_M_LFDEG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBGZ_STR-SW_LFDEG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBGZ_STR-D_EZEG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBGZ_STR-D_M_EZEG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBGZ_STR-SW_EZEG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBGZ_STR-D_BBGRUKUG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBGZ_STR-D_M_BBGRUKUG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBGZ_STR-SW_BBGRUKUG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.